SETUP
The
1.DIP Switch Setting (See page 10)
2.Data Switch Setting
For setting the mode of communication between the
3.Alarm Switch Setting
For setting up the alarm terminal. Turn off the power before setting this switch.
4.Setup of
Display the Setup menu (see page 17) to setup the
■Data Switch Setting
Set this switch to specify the mode of communication between the
•Coaxial Multiplex communication via a coaxial cable
In this mode, control signals transmitted to the combi- nation camera are multiplexed with the video signals. Allows control of a camera installed at a distance of up to 900 m (3 000 ft) from the
•
In this mode, control signals transmitted to the combi- nation camera are separated into video signals and control signals.
Allows control of a camera installed at a distance 1 200 m (4 000 ft) or more from the
Note: Keep the power switch in the off position while setting each switch (DATA, TERM, LINE). The switch setting will not take effect if the power is on.
Rear Panel
RS485 DATA
T R TERM LNE
G B A B A ON 4 COAX
OFF 2 RS485
Coaxial Multiplex communication
Set the 4 or 2 position according to the desired data line selection mode.
Set to ON position in case of terminating.
■Alarm Switch Setting
●For Using Alarm Input/Output Terminal and Alarm Recovery Input/Output Terminal
Place the Alarm Switch in the upper position for the following uses:
•Connection with the Time Lapse VCR.
•Transmitting the alarm signal to external devices.
•Resetting the alarm signal from external devices.
●For Using Alarm Input Terminals 1-4
Place the Alarm Switch in the lower position to use alarm input terminals
This allows input of up to four alarm signals into the WV- CU161.
Also allows programming the alarm switch to activate four preset positions for a connected combination camera.
Note: Keep the power switch in the off position while setting the alarm switch. The switch setting will not take effect if the power is on.
For using alarm input/output terminal and alarm recovery input/output terminal
For using alarm input terminal
ALARM
ALARM IN
ALARM OUT
RECOVER IN
RESET OUT
4 3 G 2 1
ALARM IN
9