Pitco Frialator SSHLV14 Beeper Volume and Tone, Language Selection, Melt Cycle Type

Page 23

INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL

5.15.BEEPER VOLUME AND TONE:

Volume and Tone of the beeper alarm may be changed in this section. Volume ranges are 1,2 and 3, where 3 is the loudest setting.

With display showing [PROGRAM], press the product key [0].

 

 

3

 

Display will show [SELECT] [OPTIONS]. Press product key 3, display shows

 

 

[VOLUME n] [BEEPER]. Use the product key [0] to scroll through choices (n= 1,2,3,

 

 

 

 

or T). Beeper volume will change as each selection is made.

 

 

If “T” is selected an additional display is shown, [TONE n] [BEEPER]. Use the product

 

 

 

 

 

 

key [0] to scroll through choices (n= 1,2,3). Beeper tone will change as each selection is made. Press [P] key to save choice. Display shows [PROGRAM].

5.16.LANGUAGE SELECTION:

With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 4, display shows [ENGLISH] [LANGUAGE].

Use the product key [0] to scroll through choices (ENGLISH, ESPANOL, FRANCAIS, DEUTSCH, HOLLAND).

Press [P] key to save choice. Display shows [PROGRAM].

4

5.17.MELT CYCLE TYPE:

This adjustment allows selection of the melt cycle type, or, disabling the melt cycle requirement when

starting the appliance from a cold start.

 

With display showing [PROGRAM], press the product key [0].

 

Display will show [SELECT] [OPTIONS].

 

5

Press product key 5, display shows [LIQUID], the default setting.

 

Use the product key [0] to scroll through choices (liquid, solid, no melt).

 

Press [P] key to save choice. Display will again return to [PROGRAM].

 

5.18.RECOVERY TEST VALUE:

This controller maintains a record of heat up times for the appliance. A poorly running appliance will have increased recovery times stored in this display. There is no selection done here, just the display of recovery time values.

With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 6; display will show [RECOVERY] [TEST].

Press the product key [0]. Display will show [FnnnLyyy], where nnn is the factory recovery value, and yyy is the last warm up recovery value. After recording these values, press the [P] key. Display returns to [PROGRAM].

5.19.CONTROL OR TIMER: (LEFT SIDE OF DUAL OR SINGLE VAT)

With display showing [PROGRAM], press the product key [0]. Display shows [SELECT] [OPTIONS].

Press product key 7; display will show [CONTROL].

Use the product key [0] to scroll through choices (Control, Timer). Press [P] key to save choice. Display shows [PROGRAM].

6

7

Note: If timer is selected, heat control outputs are disabled, leaving only the timer functions active. Do not make this selection on SSHLV fryer models.

L20-407 rev. 1 (3/14)

23

Image 23
Contents Reduced OIL Volume Frying System To the Purchaser To the PURCHASER, Owner and Store ManagerAppliance Start UP Preventative Maintenance Theory of Operation Checking and Unpacking Your NEW Appliance InstallationInstallation Clearances Caster and leg types Leveling the Fryer LEGS/CASTERSQuick Disconnect Connection Fuel Supply Line Leak and Pressure TestingInstallation Setup GAS ConnectionElectrical Connections Ventilation and Fire Safety SystemsInspection Probe High Temperature LimitLighting Instructions Initial AdjustmentsFilling the Appliance OFF Main Burner System AdjustmentInitial Cleaning Operation Operational FeaturesBasic Operational Features Push Button TOP OFF System is not Intended to Fill FRY Pots Filling the FRY POTFilling the Tank with Liquid Shortening Θερμοκρασια Λαδιου OIL TemperatureTemperature DELL’OLIO Appliance Start UPCooking Tips CookingComputer Controller Operation Manual Boil Entry To View Current Settings for COOK, SHAKE, and Hold TimesAutomatic Boil Entry Water Detection To Enter Programming Level 1 for the Store Manager To SET Cook TemperatureTo Enter Programming Level 2 for the Store Manager Hold PRE-ALARMPassword Change or REQUIRED? To Exit Level 1 ProgrammingLanguage Selection Beeper Volume and ToneRecovery Test Value Control or Timer Left Side of Dual or Single VATFlush Hose Operation if Equipped Control or Timer Right Side of Dual VATOther Displays Computer ShutdownAutomatic OIL TOP System Option Basket Lift OperationPush Button OIL TOP OFF System Quick Strain Filtering Filter Soon light flashing Cook Counter AdjustmentAppliance Shutdown Preventative MaintenanceReplacing the Filter Media if Equipped Appliance Inspection Cleaning the Cook TankCleaning the Cabinet Filter Cleaning if EquippedBoil OUT Procedure Weekly Preventative MaintenanceMonthly Preventative Maintenance Temperature Check Mechanical Inspection ANNUAL/PERIODIC Preventative Maintenance and InspectionSafety Evaluation Temperature Control SystemVentilation Hood GAS Combustion SystemDrain Valve Interlock TroubleshootingPower Failure High Temperature Limit SwitchSelf Cleaning Burner System not on ALL Models Filter Troubleshooting Chart if Equipped Troubleshooting Charts Fryer Troubleshooting ChartComputer & Digital Controller Displays if Equipped Display Problems ActionL20-407 rev 01/13