13.4.SELF CLEANING BURNER SYSTEM (NOT ON ALL MODELS)
If your appliance is equipped with the self cleaning burner system, the appliance should behave as outlined in the table below. A cleaning cycle will execute every time the appliance is turned “ON” from an “OFF” state. The thermal cut out switch is designed to disable the appliance if the Self Cleaning Burner System malfunctions and remains activated for an extended period of time or if there is a downdraft into the flue or a blocked flue situation.
Event | Duration | Indication | |
Turn appliance “ON” | N/A | Control Illuminates, pilot sparks and ignites. | |
pulse is initiated. | |||
|
| ||
2 seconds | Appliance operates briefly and stops. Pilot remains lit. | ||
Interwaiting period 1 | 5 seconds | Appliance does not operate. Pilot remains lit. | |
|
| Main valve operates, lighting main burners. SCBS valve | |
Cleaning Pulse | 6 seconds | operates, feeding gas to the SCBS Arm. The SCBS arm | |
ignites, initiating a brief burn at the main burner orifice of | |||
|
| ||
|
| each burner. | |
Interwaiting period 2 | 8 seconds | The Main and SCBS valves | |
The pilot remains lit. | |||
|
| ||
|
| The appliance operates normally and begins to heat up. | |
Normal operation | N/A | The SCBS Valve remains | |
resumes | the appliance is recycled. There is no flame on the | ||
| |||
|
| SCBS Arm. There is no burn at the main burner orifices. |
13.5.RESETTING THE SELF CLEANING BURNER SYSTEM TEMPERATURE LIMIT SWITCH
1.Turn the appliance off.
2.Allow the appliance ample time to cool to room temperature.
3.Press the SCBS high limit reset button. The reset button is located behind the front panel at the top of the main burners.
4.The SCBS high limit switch is now reset and ready for startup.
5.If the SCBS high temperature limit switch continues to trip, have the appliance inspected by an Authorized Professional.