Pitco Frialator SSHLV14 operation manual Troubleshooting Charts Fryer Troubleshooting Chart

Page 36

INSTALLATION & OPERATIONAL SGLV MANUAL

13.6.TROUBLESHOOTING CHARTS

13.6.1. FRYER TROUBLESHOOTING CHART

Problem

Probable Causes

Corrective Actions

 

No power to appliance.

Check main building power supply.

 

Controller not turned on.

Turn on controller.

Controller does

Power Cord loose or not

Connect power cord.

connected.

not activate.

 

Main circuit breaker to

Reset circuit breaker

 

 

appliance has tripped.

 

 

 

Appliance fuse has blown.

Contact Authorized Service Company.

 

High temperature limit has

Allow appliance to cool and reset High

Controller is on

tripped.

temperature limit.

and appliance will

SCBS thermal limit switch has

Depress button on thermal limit switch to reset. If

not heat up.

problem continues, Contact Authorized Service

 

tripped.

Company.

 

 

Appliance will not

Faulty temperature probe.

Contact Authorized Service Company.

maintain

 

 

temperature

Faulty High temperature limit.

Contact Authorized Service Company.

properly.

 

 

 

Computer display

 

 

shows off and can

Faulty computer

Contact Authorized Service Company.

not be turned on.

 

 

 

 

 

13.6.2. FILTER TROUBLESHOOTING CHART (IF EQUIPPED)

Problem

Probable Causes

Corrective Actions

Filter pump does

Filter pump circuit breaker or

Reset circuit breaker/ allow motor to cool, press

not activate.

thermal overload has tripped.

RED reset button on motor.

Oil/shortening is

Dirty filter paper

Change filter paper.

returning to the

Strainer cap dirty

Remove strainer cap and clean.

tank slowly or not

Filter pan not pushed in

Push filter pan in.

at all.

completely.

 

Excessive air

Pickup tube screen not tight.

Tighten pickup tube screen cap.

Pickup tube screen cap

Locate and install pickup tube screen cap.

bubbles are in the

missing

oil being returned

 

 

Filter pan not pushed in

 

to the tank.

Push filter pan in to complete connection.

completely

 

 

Drain valve is

Blue drain valve handle not

Verify that drain valve handle is completely

closed, but the

completely closed

closed.

computer

 

 

controller still

Improperly adjusted or

Contact Authorized Service Company.

displays

defective drain switch.

 

“DRAINING”

 

 

36

L20-407 rev.1 (3/14)

Image 36
Contents Reduced OIL Volume Frying System To the PURCHASER, Owner and Store Manager To the PurchaserAppliance Start UP Preventative Maintenance Theory of Operation Installation Installation ClearancesChecking and Unpacking Your NEW Appliance Leveling the Fryer LEGS/CASTERS Caster and leg typesFuel Supply Line Leak and Pressure Testing Installation SetupGAS Connection Quick Disconnect ConnectionVentilation and Fire Safety Systems Electrical ConnectionsProbe High Temperature Limit InspectionInitial Adjustments Filling the ApplianceLighting Instructions Main Burner System Adjustment OFFInitial Cleaning Operational Features OperationBasic Operational Features Filling the FRY POT Filling the Tank with Liquid ShorteningPush Button TOP OFF System is not Intended to Fill FRY Pots OIL Temperature Temperature DELL’OLIOAppliance Start UP Θερμοκρασια ΛαδιουCooking Cooking TipsComputer Controller Operation To View Current Settings for COOK, SHAKE, and Hold Times Automatic Boil Entry Water DetectionManual Boil Entry To SET Cook Temperature To Enter Programming Level 1 for the Store ManagerHold PRE-ALARM Password Change or REQUIRED?To Exit Level 1 Programming To Enter Programming Level 2 for the Store ManagerBeeper Volume and Tone Recovery Test ValueControl or Timer Left Side of Dual or Single VAT Language SelectionControl or Timer Right Side of Dual VAT Other DisplaysComputer Shutdown Flush Hose Operation if EquippedBasket Lift Operation Push Button OIL TOP OFF SystemAutomatic OIL TOP System Option Cook Counter Adjustment Quick Strain Filtering Filter Soon light flashingPreventative Maintenance Appliance ShutdownReplacing the Filter Media if Equipped Cleaning the Cook Tank Cleaning the CabinetFilter Cleaning if Equipped Appliance InspectionWeekly Preventative Maintenance Monthly Preventative MaintenanceBoil OUT Procedure Temperature Check ANNUAL/PERIODIC Preventative Maintenance and Inspection Safety EvaluationTemperature Control System Mechanical InspectionGAS Combustion System Ventilation HoodTroubleshooting Power FailureHigh Temperature Limit Switch Drain Valve InterlockSelf Cleaning Burner System not on ALL Models Troubleshooting Charts Fryer Troubleshooting Chart Filter Troubleshooting Chart if EquippedDisplay Problems Action Computer & Digital Controller Displays if EquippedL20-407 rev 01/13