Sterling 682.88107.00 specifications Technical Specifications, Annex B Information

Page 40

7-2 Technical Specifications

Annex B Information

The following design information is provided for your reference:

1.

No modifications are allowed to this equipment that could alter the CE compliance

2.

Ambient temperature:

40 degrees Celsius – Maximum (104 degrees Fahrenheit)

3.

Humidity range:

50% relative humidity

 

4.

Altitude:

Sea level

 

 

5.

Environment:

Clean, dust-free and non-explosive

 

6.

Radiation:

None

 

 

7.

Vibration:

Minimal, i.e. machine mounting

 

8.

Allowable voltage fluctuation:

+/- 10%

 

9.

Allowable frequency fluctuation:

Continuous

+/- 1%

10.

Intermittent

 

+/- 2%

 

11.

Nominal supply voltage:

460/3/60 (Verify on serial number tag)

12.

Earth ground type:

TN (system has one point directly earthed through a

 

protective conductor)

 

 

 

13.Power supply should include a ground connection.

14.Over-current protection is supplied in the tcu, but additional protection should be supplied by the user.

15.The door-mounted disconnect serves as the electrical disconnect device.

16.Tcu is not equipped with local lighting.

17.Functional identification

18.Tcu is equipped with a CE mark

19.Tcu is supplied with an operating manual in the language of the destination country.

20.Cable support may be required for power cord, depending on final installation.

21.No one is required to be in the interior of the electrical enclosure during the normal operation of the unit. Only skilled electricians should be inside the enclosure for maintenance.

22.Doors can be opened with a screwdriver, but no keys are required.

23.Two-hand control is not required or provided.

24.All tcus should be moved around and set in a place with a lift truck or equivalent.

25.There are no frequent repetitive cycles that require manual control⎯repetitive functions are automatic while the tcu is operating.

26.An inspection report detailing the functional test is included with the tcu.

27.The machine is not equipped with cableless controls.

28.Color-coded (harmonized) power cord is sufficient for proper installation.

Upright Portable Hot Oil TCUs

Chapter 7: Appendix

40

Image 40
Contents Upright Hot Oil Temperature Control Units Shipping Info Table of Contents Troubleshooting How to Use This Manual SafetySafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility RememberMaintenance Responsibility Reporting a Safety DefectStandard Features Mechanical FeaturesFunctional Description Models Covered in This ManualController Features Electrical FeaturesOptions Feature Descriptions Immersion HeatersHeater Tank PumpElectrical System Controls Connection LinesElectrical Panel and System Components Pressure Switch Safety ThermostatAir Purge Reservoir TankSafety Circuit Standards Safety Devices and InterlocksCooling Optional Safety Device Lock-Outs Fail Safe OperationInstallation Installation Location ConsiderationsUncrating the Equipment Rigging and Placing the TCUElectrical Connections Connecting Piping Setup ProceduresPiping Considerations for Mobile Installations Connecting Cooling Water Piping Connecting Process PipingConnecting Vent Piping Upright Unit Piping Setup Initial Start-up Starting the Hot Oil TCUPage Start-up OperationController Description & Operation Identifying Control Panel Switches Control Panel SwitchesIdentifying System Status Board Indicators System Status Board IndicatorsMode Indicator Lights Status Indicator LightsFault Indicator Lights Returning Fluid to the Tank Shutting Down the Hot Oil TCUPage Maintenance Schedule MaintenancePhotocopy this page for your maintenance records Preventative Maintenance Preventative Pump MaintenanceRoutine Servicing Draining the Unit for StorageCorrective Maintenance Adjusting End ClearanceCleaning the Pump Examining Internal PartsMaintaining the Pump Disassembling the PumpPump Assembly Thrust Bearing Adjustment Installation of Carbon Graphite BushingsProblem Possible cause Corrective action TroubleshootingIntroduction OFF Problem Possible cause Corrective action Appendix Optional ComponentsTechnical Specifications Annex B InformationUpright Portable Hot Oil TCUs Appendix Drawings and Diagrams 18-24 GPM Pump ConstructionThrust Bearing Assembly Belt Tensioning Instructions Spare Parts List Immersion Heaters Part number DescriptionHeater Gasket Part number Description 542-00007-08 Pilot Lights Part number DescriptionSelector Switches and Push Buttons Pressure SwitchesControllers Part number Description Part number DescriptionDisconnect Switches Solenoid Valves Part number DescriptionSensing Probe Equipment Heater Tank InsulationSafety Tag Information Warranty ReturnsTCU Safety Tags Returned Material PolicyTCU Identification Serial Number Tag Technical Assistance