| Troubleshooting | EN |
Problem | Possible cause | Solution |
|
High pitched noise. | Units are too close to | Move parent unit away | |
| each other. | from baby unit (at least | |
|
| 1 meter / 3 feet). | |
| Volume on parent unit | Decrease volume | |
| set too high. | parent unit. | |
|
|
|
|
No sound/ | Volume on parent unit is |
baby’s crying cannot | set too low or switched off. |
be heard. |
|
Increase volume on parent unit
| Microphone sensitivity level | Adjust microphone sensitivity |
| set too low on parent unit. | level |
|
| to a higher level. |
| Units are out of range | Move parent unit closer to baby |
|
| unit. |
|
|
|
Parent unit reacts | Ambient sounds trigger | Move baby unit closer to |
too fast to other | transmission. | baby (keep minimal distance of |
ambient sounds. |
| 1 meter / 3 feet). |
| Microphone sensitivity | Decrease microphone sensitivity |
| set too high. | level |
|
|
|
Parent unit reacts slowly/ | Microphone sensitivity is | Increase microphone sensitivity |
late to baby's crying. | set too low. | level |
|
| move baby unit closer to baby |
|
| (keep minimal distance of 1 meter |
|
| / 3 feet). |
|
|
|
Battery check light ( ) | Batteries are low or almost |
is lit. | empty. |
Replace batteries
Baby unit battery power | Microphone sensitivity is set |
diminishes rapidly. | too high. Unit consumes |
| more power. |
Set microphone sensitivity to a lower level
Volume setting too high. | Set volume to a lower level |
Charging time of parent unit batteries exceeds 16 hours.
Parent unit switched on during | Switch off parent unit |
charging. |
|
17