TROUBLESHOOTING

Make sure all parts are properly tightened each time the weight system is used. Replace any worn parts immedi- ately. The weight system can be cleaned using a damp cloth and mild non-abrasive detergent. Do not use solvents.

TIGHTENING THE CABLES

Woven cable, the type of cable used on the weight system, can stretch slightly when it is first used. If there is slack in the cables before resistance is felt, the cables should be tightened. To tighten the cables, first insert the weight pins into the centers of the weight stacks. Slack can be removed from the cables in several ways:

See drawing 1. To tighten the Lat Cable (62) or the Upper Short Stack Cable (not shown), first loosen the M12 Nut (58) on the end of the Cable away from the 50mm Washer (95). Screw the end of the Cable far- ther into the Long Weight Tube (23) or the Short Weight Tube (not shown). Finally, retighten the Locknut against the Washer.

See drawing 2. Slack can be removed from the cables by moving a 100mm Pulley (38) in the Pulley Plates (41). First, remove the upper or lower M10 Nylon Locknut (101), M10 x 50mm Bolt (81), Pulley, and Long Cable Trap (68) from the Pulley Plates. Reattach the Pulley and the Cable Trap between a set of holes closer to the center of the Pulley Plates with the Bolt and Locknut. Make sure the Cable Trap is oriented to hold the cable in the groove of the Pulley.

See drawing 3. To remove additional slack, remove the M10 Nylon Locknut (101), M10 x 50mm Bolt (81), 100mm Pulley (38), and Long Cable Trap (68) from either “U”-bracket (40). Reattach the Pulley and the Cable Trap between the indicated set of holes in the “U”-bracket with the Bolt and Locknut.

See drawing 4. Slack can also be removed from the cables by tightening the M8 Nylon Locknut (87) at the end of the Leg Press Cable (65) or the Butterfly Cable (67). To do this you may need to remove the 100mm Pulley (38) from the “U”-bracket (40).

Do not overtighten the cables. If the cables are overtightened, the top weights will be lifted off the weight stacks.

If a cable slips off the pulleys repeatedly, it may have become twisted. Remove the cable and re- install it. If the cables need to be replaced, see ORDERING REPLACEMENT PARTS on the back cover of this manual.

1

 

 

62

58

 

23

95

 

2

 

38

68

 

101

41

 

 

41

81

68

38

 

3

38

 

 

68

101

81

40

 

4

 

 

38

87

40

 

100

 

 

65 or 67

31

Image 31
Contents Model No. WESY47330 Serial No QUESTIONS?Customer HOT Line Table of Contents Decal Important Precautions Before YOU Begin DimensionsMake Assembly Easier for Yourself AssemblyFrame Assembly Locknuts yet Tighten the Locknuts yetPage Tighten the M10 Nylon Locknuts 101 used in steps 1-3 Repeat this step with the Right Butterfly Arm Lubricate the four 56mm Round Bushings 53 with greaseLocknuts yet. Make sure the warining decal is Repeat with the other Seat ArmOvertighten the Locknut the Press Arm must Press Base 3 in the same mannerTighten the M10 Nylon Locknuts 101 used Be between the Leg Press Brackets 16Page Page Page Page Trap is oriented to hold the Cable Groove of the Pulley Identify the Leg Press Cable 65. Attach101 100 Large Ball Sure the Cable Trap is oriented to hold Weight systemPage Seat Assembly Holes should Be closer to This end 101 Page Repeat this step with the other Butterfly Pin Using the LEG Lever Lock AdjustmentsChanging the Weight Setting Attaching the Accessories to a Pulley StationConverting the Butterfly Arms Adjusting the SeatAttaching the Curl PAD Bottom Weight Resistance Chart Weight LEG High Butter Press LOW Pulley FLY ARM Lever Lbs Left TopLeg Press Cable Cable DiagramsUpper Short Stack Cable Lower Short Stack CableButterfly Cable Lat CableAb Cable Tightening the Cables TroubleshootingFour Basic Types of Workouts Exercise GuidelinesPersonalizing Your Exercise Program Cooling Down Muscle ChartStaying Motivated Thursday Aerobic Exercise Date Exercise Weight Sets RepsDate Aerobic ExerciseMonday Part Identification Chart Page Page Qty Description Part LIST-Model No. WESY47330Exploded Limited Warranty Ordering Replacement PartsIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT