Whirlpool W10136970C manual LocationRequirements

Page 5

Door Reversal Kit

Are you planning to reverse the door swing direction on your DUET® dryer? To do so, you will need to purchase a Door Reversal Kit.

To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or Service” section. Ask for Part Number 8579666.

Backguard

If you are installing your DUET® washer and dryer and wish to avoid having loose items fall behind your machines, you may purchase a pair of washer/dryer backguards. These will reduce the chance of items falling behind the machines during operation.

To order, call the dealer from whom you purchased your dryer or refer to the “Assistance or Service” section. Ask for Part Number 8212452 (White).

LocationRequirements

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches (46 cm) above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

You will need

A location that allows for proper exhaust installation. A gas dryer must be exhausted to the outdoors. See “Venting Requirements.”

A grounded electrical outlet located within 2 ft (61 cm) of either side of the dryer. See “Electrical Requirements.”

A sturdy floor to support the total dryer weight of 200 lbs (90.7 kg). The combined weight of a companion appliance should also be considered.

Cold water faucets located within 4 ft (1.2 m) of the dryer, and water pressure of 20-100 psi (137.9-689.6 kPa). You may use the cold water supply from your washer using the “Y” connector provided.

20-100 psi (138-690 kPa) for best performance.

A level floor with a maximum slope of 1" (2.5 cm) under entire dryer. If slope is greater than 1" (2.5 cm), install Extended Dryer Feet Kit, Part Number 279810. Clothes may not tumble properly, and automatic sensor cycles may not operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer at least 18" (46 cm) above the floor. If using a pedestal, you will need 18" (46 cm) to the bottom of the dryer.

Do not operate your dryer at temperatures below 45ºF (7ºC). At lower temperatures, the dryer might not shut off at the end of an automatic cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

Installation clearances

The location must be large enough to allow the dryer door to open fully.

Dryer Dimensions

52 ⁹⁄₁₆" (133.16 cm)

38"

(96.52 cm)

*32 ⁹⁄₁₆"

(82.65 cm)27"

(68.6 cm)

*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”

Installation spacing for recessed area or closet installation

The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:

Additional spacing should be considered for ease of installation and servicing.

Additional clearances might be required for wall, door and floor moldings.

Additional spacing should be considered on all sides of the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.

Companion appliance spacing should also be considered.

Custom undercounter installation - Dryer only

0"

 

 

(0 cm)

 

 

38" min.

 

 

(96.52 cm)

 

 

1"*

27"

1"*

(2.5 cm)

(68.6 cm)

(2.5 cm)

*Required spacing

5

Image 5
Contents W10136970C Electronic GAS DryerTable of Contents Dryer SafetyWhat to do if YOU Smell GAS Options Installation InstructionsToolsandParts LocationRequirements Mobile home Additional installation requirements Recommended installation spacing for cabinet installationCloset installation Dryer only Recessed or closet installation Dryer on pedestalGas SupplyRequirements Electrical RequirementsGas Type Gas supply lineIf using an existing vent system Gas supply pressure testingVentingRequirements Burner input requirementsIf this is a new vent system Vent material PlanVentSystemSpecial provisions for mobile home installations Optional exhaust installationsAlternate installations for close clearances Determine vent pathInstall LevelingLegs Install VentSystemVent system chart MakeGasConnectionLevelDryer ConnectVentConnectInletHose If the dryer will not start, check the following CompleteInstallationTo use an Automatic Cycle Dryer USEStartingYourDryer StoppingYourDryer PausingorRestartingTo stop your dryer at any time To pause the dryer at any timeStatusLights ControlLockedDryingandCycleTips Cycles Additional Features ChangingCycles,Options andModifiers DryingRackOptionCleaningtheLintScreen CleaningtheDryerLocationEvery load cleaning As needed cleaningRemovingAccumulatedLint CleaningtheDryerInteriorWaterInletHoses Vacation,StorageandMovingCareDryerOperation TroubleshootingLint on load Cycle time too shortStains on load or drum Loads are wrinkledInCanada AccessoriesIntheU.S.A Call Whirlpool Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheusePièces fournies Instructions D’INSTALLATIONOutillageetpièces Piédestal Pièces nécessairesNécessaire de superposition Trousse dinversion de porteIl vous faudra Exigencesd’emplacementDimensions de la sécheuse Installation dans un placard Sécheuse seulement Espacement recommandé pour linstallation dans un placardSpécifications électriques Linstallation dans une maison mobile exigeType de gaz AlimentationengazExigences concernant le raccordement au gaz Canalisation d’arrivée de gazEn cas dutilisation du système dévacuation existant ExigencesconcernantlévacuationCanalisation d’arrivée de gaz de la sécheuse Planificationdusystèmed’évacuation Installations d’évacuation facultativesBrides de serrage ÉvacuationDéterminer litinéraire dacheminement du conduit Autres installations où le dégagement est réduitInstallationdespiedsdenivellement Installationdusystèmed’évacuationRaccordementaugaz Tableau des systèmes dévacuationRaccordementduconduitd’évacuation Raccordementdes tuyauxdalimentationSi la sécheuse ne démarre pas, vérifier ce qui suit Acheverl’installationMiseàniveaudela sécheuse Utilisation dun programme automatique Utilisation DE LA SécheuseMiseenmarchedelasécheuse Utilisation dun programme Steam vapeur Comment fonctionnent les programmes automatiquesUtilisation dun programme manuel Conseils pourleséchageetles programmes ArrêtdelasécheusePauseouremiseenmarche Programmes Témoins lumineuxPréréglages des programmes automatiques Damp Dry séchage humideProgrammes manuels Timed Dry séchage minutéCaractéristiquessupplémentaires Optiondegrilledeséchage Changementdesprogrammes,optionset ModificateursButton Sound son des boutons Changement des programmes après avoir appuyé sur StartJouets rembourrés ou Séchage sur grille Réglage Temp Durée Chandails en laineOreillers Chaussures de tennis ou enEntretien DE LA Sécheuse Nettoyagedelemplacementde LasécheuseNettoyagedufiltreàcharpie Nettoyagedel’intérieurdelasécheuseTuyauxdalimentationdeau Réinstallation de la sécheuseChangementdel’ampouled’éclairage Dutambour Préparation de la sécheuse pour lhiverRésultatsdelasécheuse DépannageFonctionnementdelasécheuse Charpie sur la charge Temps de programme trop courtTaches sur la charge ou sur le tambour Charges froisséesAuCanada AccessoiresAuxÉtats-Unis W10136970C Garantie DES Gros Appareils Ménagers Whirlpool Corporation