Intel manual Rear Connector Placement, ESD Discharge Strip, MPCMM0002 CMM Rear Connectors

Page 26

Mechanical Information—MPCMM0002 CMM

There is only one ejector on the CMM, but it matches the subrack interface geometry defined in Section 2.2.7 of the PICMG 3.0 specification. Note, however, that the ejector handle is 2 mm (0.0787 inches) thick, not the 2.5 mm (0.0984 inches) thickness that many PICMG 3.0 boards use.

A switch on Component Side 2 of the PCB detects the opening and closing of the ejector handle.

5.3Rear Connector Placement

5.3.1MPCMM0002 CMM Rear Connectors

The CMM uses three connectors (for power, data, and a guide pin) that can mate with either vertical (backplane) connectors or coplanar connectors. The power connector is an FCI* 85719-107LF (or equivalent) connector. As shown in Table 14, “CMM Power Connector” on page 32, the A1 pin on the connector is located at coordinates (2.37, 96.34). The data connector is an FCI 89095-102LF (or equivalent). Pin 1 on the data connector is located at coordinates (13.7, 64.65). The guide pin connector is an FCI 73474-201 (or equivalent).

5.3.2Coplanar Mating Connectors

In a coplanar mating arrangement, a FCI* HM1L54LDP000H6P connector with FCI* 72019-101 guide pin is mated to the data connector on the CMM, while a FCI* HM1L52LDP493H6P (or equivalent) connector mates with the power connector.

5.3.3Vertical Mating Connectors

When a CMM board mates directly into a backplane, vertical mating connectors are used. The data connector that mates to the CMM is a FCI* 89009-116 with FCI* 70295-001 guide pin and 73475-101 shroud, while the power connector is an FCI* HM1W52ZPR493H6P (or equivalent). Since they are mounted on a backplane, the rear of these two connectors must be in the same plane.

Example: If mounted horizontally with Component Side 1 up, the bottom row of holes for the data connector is 1.775 mm (0.0699 inches) lower than the power connector.

5.4ESD Discharge Strip

The ESD strip along the bottom of the CMM follows the guidelines in Section 2.2.5 of the PICMG* 3.0 specification. The electrical definition of the ESD discharge strip is shown below.

Figure 10. CMM ESD Strip Electrical Definition

10MΩ

10MΩ

Dimensions of the ESD strips are shown in Table 16, “Ethernet Port Pinouts” on page 47.

 

Intel NetStructure® MPCMM0002 Chassis Management Module

July 2007

Hardware TPS

Order Number: 309247-004US

27

Image 26
Contents Hardware Technical Product Specification Intel NetStructure MPCMM0002 Chassis Management ModuleOrder Number 309247-004US Contents 17.4 Figures TablesOrder Number 309247-004US Revision History Date Revision DescriptionDocument Organization Acronym/Term Meaning Acronyms and TermsAcronyms and Terms User Documentation Architecture SpecificationIntroduction Product DefinitionMPCMM0002 CMM-Introduction Installing the CMM Getting StartedQuick Start Block Diagram Module ComponentsCMM Top View Layout Processor Features Sheet 1 Intel 80321 ProcessorProcessor Features Sheet 2 PbgaSerial Port UARTs MemoryEthernet Fpga Watchdog TimerFpga Features Redundancy and Hot Swap CpldRide-Through Support 10 ADM1026 ControllerHot Swap Controller Ipmb Isolation LogicDual Bus Ipmb Isolation Requirements Ipmb Dual Star IsolationFpga Dimensions Mechanical InformationCMM Backing Plate Dimensions CMM Side View Dimensions Front Panel HardwareCoplanar Mating Connectors Rear Connector PlacementMPCMM0002 CMM Rear Connectors Vertical Mating ConnectorsBackplane Considerations CMM PowerDC Power Input Ipmb RoutingVoltage Usage CDM PowerVoltage Max Where Used Monitored By Current Power Switch Filter TrayChassis Component Element Ethernet RoutingChassis Elements Directly Driven by CMM Hardware Rear Connections CMM Connector PinoutsCMM Power Connector Power Connector Pinouts Pin Signal Purpose Pin LengthPin Staging Power Connector Pinouts MatrixPower Connector Receptacle Pin Placement Sheet 1 Order Mating Tail Pin Code LengthRear Connections-MPCMM0002 CMM CMM Data Connector CMM Data ConnectorData Connector Pinouts Sheet 1 Signal Name Count Type Description Pin Name From TableData Connector Pinouts Sheet 2 Data Connector Pinouts Matrix Sheet 1Data Connector Pinouts Matrix Sheet 2 Data Connector Pinouts Matrix Sheet 3 Order Mating Length Tail Length Pin CodeGuide Post CMM RedundancyMPCMM0002 CMM-Rear Connections CDM Management Chassis Data Modules CDMsCDM Overview CDM Health LED StatesCDM Power CDM RedundancyFront Panel Serial Port PinoutsSerial Port RJ-45 Connector Pin Signal DescriptionEthernet Port Pinouts Ethernet Port PinoutsLED Color Status Description Telco Alarm ConnectorEthernet Port LED States Pin Description Cascading the Telco Alarm ConnectorsTelco Alarm Pinout MxxReset Input Alarm Quiet Switch Ganged Telco Alarm Cable Pinouts with CablingLEDs Alarm LEDsLED Symbol Status Description User-Definable LEDs Health LEDHot Swap LED CMM Health LED StatesChassis Ground and Logic Ground Grounding ConsiderationsESD Discharge Protection Module Orientation ThermalsProcessor Heat Sink Module Airflow PathSide-to-Side Air Flow Typical Airflow and Cooling Requirements Airflow RequirementsBoard Resistance Curve Category CMMsMinimum Air Flow Air Temp Rise Thermal SensorsAirflow Guidelines Management Module Specifications Feature SummaryDimensions and Weight Dimensions and Weight12.3 Environmental Characteristics Environmental CharacteristicsReliability Estimate Data Agency CertificationsAssumptions and Notes Reliability Measure Value UnitsGuidelines for Third Party Chassis Vendors High Level DesignO Signals of the CMM Ipmb BusesIpmb Signal Physical Bus Number Physical Bus Number MappingRadial Bus Topologya Gpio Pins Dedicated I/O PinsExample Configurations Interfacing FRUs to the CMMFRUs Based on the ADM1026 Intelligent FRUsNon-Intelligent FRUs with I2C* Support FRU Data Storage for Non-Intelligent Devices Two-Wire Serial Interface BasedNon-Intelligent FRUs without I2C Support Related Documents Temperature Sensors Fronted by the CMMControllers and I/O Ports for Non-Intelligent Devices Related DocumentsWarranty Information Returning a Defective Product RMAFor Asia and Pacific Apac For the AmericasFor Europe, Middle East, and Africa Emea Warranty Information-MPCMM0002 CMM Customer Support Technical Support and Return for Service AssistanceCustomer Support Sales AssistanceMaterial Declaration Data Sheet CertificationsMaterial Declaration Data Sheet Agency Information North America FCC Class aEnglish Safety Instructions English and French-translated belowTaiwan Class a Warning Statement FrenchJapan Vcci Class a Korean Class a Australia, New Zealand Safety Warnings Mesures de Sécurité MPCMM0002 CMM-Safety Warnings Sicherheitshinweise MPCMM0002 CMM-Safety Warnings Norme di Sicurezza MPCMM0002 CMM-Safety Warnings Instrucciones de Seguridad MPCMM0002 CMM-Safety Warnings Chinese Safety Warning MPCMM0002 CMM-Safety Warnings Fpga Working page only. Do not distribute Working page only. Do not distribute Working page only. Do not distribute