Intel MPCMM0002 manual Data Connector Pinouts Sheet 1

Page 36

Rear Connections—MPCMM0002 CMM

The pinouts for the data connector are shown in Table 11.

Table 11.

Data Connector Pinouts (Sheet 1 of 2)

 

 

 

 

 

 

 

Signal Name

 

Count

Type

Description

Pin Name From Table 12

 

 

 

 

 

 

BP_AFT1

 

1

I

Filter tray ambient temperature thermistor A

E16

 

 

 

 

 

 

BP_AFT2

 

1

I

Filter tray ambient temperature thermistor B

E17

 

 

 

 

 

 

BP_AFTREF

 

1

I

Filter tray ambient temperature thermistor return

E18

 

 

 

 

 

 

BP_AFLED[1:2]

 

2

O

Filter tray status tri-color LED control. Bit 1

E19, E20

 

controls the red LED. Bit 2 controls the green LED.

 

 

 

 

 

 

 

 

 

 

 

BP_AFPRES#

 

1

I

Filter tray presence. This signal is pulled up to

E21

 

+3.3V and is de-bounced by software.

 

 

 

 

 

 

 

 

 

 

 

RP_ENET1_LNK#

 

1

O

Ethernet port 1 to RTM Link LED drive

A29

 

 

 

 

 

 

RP_ENET1_ACT#

 

1

O

Ethernet port 1 to RTM Activity LED drive

A30

 

 

 

 

 

 

RP_ENET1_SPD#

 

1

O

Ethernet port 1 to RTM speed indicator

A31

 

 

 

 

 

 

RP_ENET2_LNK#

 

1

O

Ethernet port 2 to RTM Link LED drive

B29

 

 

 

 

 

 

RP_ENET2_ACT#

 

1

O

Ethernet port 2 to RTM Activity LED drive

B30

 

 

 

 

 

 

RP_ENET2_SPD#

 

1

O

Ethernet port 2 to RTM speed indicator

B31

 

 

 

 

 

 

 

 

 

 

Control signals for ShFRU status tri-color LED 1.

 

FRU0_STATUS[0:1]

1

O

Bit 0 controls the red LED. Bit 1 controls the green

D30, D31

 

 

 

 

LED.

 

 

 

 

 

 

 

 

 

 

 

Control signals for ShFRU status tri-color LED 2.

 

FRU1_STATUS[0:1]

1

O

Bit 0 controls the red LED. Bit 1 controls the green

C30, C31

 

 

 

 

LED.

 

 

 

 

 

 

 

 

 

 

 

Power switch input A or B from system power on/

 

PWRSW[1:2]

 

2

I

off switch. These two signals have to be

E30, E31

 

 

 

 

debounced by software.

 

 

 

 

 

 

BP_N_SCL[0..15]A and B

32

OD

Node IPMB clock

A2-A17, C2-C17

 

 

 

 

 

BP_N_SDA[0..15]A and B

32

OD

Node IPMB data

B2-B17, D2-D17

 

 

 

 

 

BP_CF_SCL_A and B

2

OD

Chassis FRU IPMB clock

A18, C18

 

 

 

 

 

BP_CF_SDA_A and B

2

OD

Chassis FRU IPMB data

B18, D18

 

 

 

 

 

BP_SH_SCL_A and B

2

OD

Shared Bus IPMB clock

A19, C19

 

 

 

 

 

BP_SH_SDA_A and B

2

OD

Shared Bus IPMB data

B19, D19

 

 

 

 

 

BP_RED_SCL_A and B

2

OD

Redundant CMM IPMB serial clock

A20, C20

 

 

 

 

 

BP_RED_SDA_A and B

2

OD

Redundant CMM IPMB serial data

B20, D20

 

 

 

 

 

BP_RP_SCL_A and B

2

OD

Reserved IPMB clocks for RTM

A21, C21

 

 

 

 

 

BP_RP_SDA_A and B

2

OD

Reserved IPMB data for RTM

B21, D21

 

 

 

 

 

BP_SP_SCL_A and B

2

OD

RESERVED FOR FUTURE USE

A22, C22

 

 

 

 

 

BP_SP_SDA_A and B

2

OD

RESERVED FOR FUTURE USE

B22, D22

 

 

 

 

 

BP_ENET1_TX0(+-)

2

I/O

Ethernet port 1 to RTM

A33, B33

 

 

 

 

 

BP_ENET1_RX0(+-)

2

I/O

Ethernet port 1 from RTM

A35, B35

 

 

 

 

 

BP_ENET2_TX0(+-)

2

I/O

Ethernet port 2 to RMT

A37, B37

 

 

 

 

 

BP_ENET2_RX0(+-)

2

I/O

Ethernet port 2 from RTM

A39, B39

 

 

 

 

 

BP_ENET1_TX1(+-)

2

I/O

Reserved for GbE to RTM

D33, E33

 

 

 

 

 

BP_ENET1_RX1(+-)

2

I/O

Reserved for GbE from RTM

D35, E35

 

 

 

 

 

BP_ENET2_TX1(+-)

2

I/O

Reserved for GbE to RTM

D37, E37

 

 

 

 

 

BP_ENET2_RX1(+-)

2

I/O

Reserved for GbE from RTM

D39, E39

 

 

 

 

 

 

 

Intel NetStructure® MPCMM0002 Chassis Management Module

July 2007

Hardware TPS

Order Number: 309247-004US

37

Image 36
Contents Hardware Technical Product Specification Intel NetStructure MPCMM0002 Chassis Management ModuleOrder Number 309247-004US Contents 17.4 Figures TablesOrder Number 309247-004US Revision History Date Revision DescriptionDocument Organization Acronyms and Terms Acronyms and TermsAcronym/Term Meaning Architecture Specification IntroductionUser Documentation Product DefinitionMPCMM0002 CMM-Introduction Installing the CMM Getting StartedQuick Start Block Diagram Module ComponentsCMM Top View Layout Processor Features Sheet 1 Intel 80321 ProcessorProcessor Features Sheet 2 PbgaMemory EthernetSerial Port UARTs Watchdog Timer Fpga FeaturesFpga Redundancy and Hot Swap Cpld10 ADM1026 Controller Hot Swap ControllerRide-Through Support Ipmb Isolation LogicDual Bus Ipmb Isolation Requirements Ipmb Dual Star IsolationFpga Dimensions Mechanical InformationCMM Backing Plate Dimensions CMM Side View Dimensions Front Panel HardwareRear Connector Placement MPCMM0002 CMM Rear ConnectorsCoplanar Mating Connectors Vertical Mating ConnectorsCMM Power DC Power InputBackplane Considerations Ipmb RoutingCDM Power Voltage Max Where Used Monitored By CurrentVoltage Usage Power Switch Filter TrayEthernet Routing Chassis Elements Directly Driven by CMM HardwareChassis Component Element CMM Connector Pinouts CMM Power ConnectorRear Connections Power Connector Pinouts Pin Signal Purpose Pin Length Power Connector Pinouts Matrix Power Connector Receptacle Pin Placement Sheet 1 Pin Staging Order Mating Tail Pin Code LengthRear Connections-MPCMM0002 CMM CMM Data Connector CMM Data ConnectorData Connector Pinouts Sheet 1 Signal Name Count Type Description Pin Name From TableData Connector Pinouts Sheet 2 Data Connector Pinouts Matrix Sheet 1Data Connector Pinouts Matrix Sheet 2 Data Connector Pinouts Matrix Sheet 3 Order Mating Length Tail Length Pin CodeGuide Post CMM RedundancyMPCMM0002 CMM-Rear Connections Chassis Data Modules CDMs CDM OverviewCDM Management CDM Health LED StatesCDM Power CDM RedundancyFront Panel Serial Port PinoutsSerial Port RJ-45 Connector Pin Signal DescriptionEthernet Port Pinouts Ethernet Port PinoutsTelco Alarm Connector Ethernet Port LED StatesLED Color Status Description Cascading the Telco Alarm Connectors Telco Alarm PinoutPin Description MxxReset Input Alarm Quiet Switch Ganged Telco Alarm Cable Pinouts with CablingAlarm LEDs LED Symbol Status DescriptionLEDs Health LED Hot Swap LEDUser-Definable LEDs CMM Health LED StatesGrounding Considerations ESD Discharge ProtectionChassis Ground and Logic Ground Thermals Processor Heat SinkModule Orientation Module Airflow PathSide-to-Side Air Flow Airflow Requirements Board Resistance CurveTypical Airflow and Cooling Requirements Category CMMsThermal Sensors Airflow GuidelinesMinimum Air Flow Air Temp Rise Management Module Specifications Feature SummaryDimensions and Weight 12.3 Environmental CharacteristicsDimensions and Weight Environmental CharacteristicsAgency Certifications Assumptions and NotesReliability Estimate Data Reliability Measure Value UnitsGuidelines for Third Party Chassis Vendors High Level DesignO Signals of the CMM Ipmb BusesIpmb Signal Physical Bus Number Physical Bus Number MappingRadial Bus Topologya Gpio Pins Dedicated I/O PinsExample Configurations Interfacing FRUs to the CMMIntelligent FRUs Non-Intelligent FRUs with I2C* SupportFRUs Based on the ADM1026 Two-Wire Serial Interface Based Non-Intelligent FRUs without I2C SupportFRU Data Storage for Non-Intelligent Devices Temperature Sensors Fronted by the CMM Controllers and I/O Ports for Non-Intelligent DevicesRelated Documents Related DocumentsWarranty Information Returning a Defective Product RMAFor the Americas For Europe, Middle East, and Africa EmeaFor Asia and Pacific Apac Warranty Information-MPCMM0002 CMM Technical Support and Return for Service Assistance Customer SupportCustomer Support Sales AssistanceMaterial Declaration Data Sheet CertificationsMaterial Declaration Data Sheet Agency Information North America FCC Class aSafety Instructions English and French-translated below Taiwan Class a Warning StatementEnglish FrenchJapan Vcci Class a Korean Class a Australia, New Zealand Safety Warnings Mesures de Sécurité MPCMM0002 CMM-Safety Warnings Sicherheitshinweise MPCMM0002 CMM-Safety Warnings Norme di Sicurezza MPCMM0002 CMM-Safety Warnings Instrucciones de Seguridad MPCMM0002 CMM-Safety Warnings Chinese Safety Warning MPCMM0002 CMM-Safety Warnings Fpga Working page only. Do not distribute Working page only. Do not distribute Working page only. Do not distribute