MPCMM0002
Figure 12. CDM Power Input
CDM 1 |
| CDM 2 |
|
|
|
6.2.3Filter Tray
The CMM also provides direct support for a filter tray. The CMM provides signals to handle a filter presence switch, two thermistors, and a tricolor LED.
The filter presence switch is typically a mechanical switch that connects the AF_PRES# signal to ground when an air filter is installed in the chassis. The switch is debounced in software.
The two thermistor inputs provide redundant temperature readings to the CMM. The thermistors should be a NTC (negative thermocouple) device like the US Sensor* USX2257 thermocouple (http://www.ussensor.com/). For maximum accuracy, a dedicated logic ground reference signal AFTREF is provided to isolate localized perturbations to logic ground. Chassis designers should use the AFTREF signal exclusively for these thermocouples and should route the two temperature signals and the reference signal in close proximity.
6.2.4Power Switch
The CMM has support for an optional soft power switch. This
These direct drive capabilities of the CMM are summarized in the table below. All the outputs are protected via
Intel NetStructure® MPCMM0002 Chassis Management Module |
|
Hardware TPS | July 2007 |
30 | Order Number: |