Weber 89478 manual Refilling the Liquid Propane Cylinder, Checking the Fuel Level in Your Tank

Page 12

GAS INSTRUCTIONS

Check:

A)Hose to manifold connection (1).

B)Side burner hose to manifold connection and side burner hose to side burner gas line connection (2).

C) Side burner hose to side burner connection, side burner valve and orifice connections (3).

WARNING: If there is a leak at connection (1, 2, or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

D)Regulator to cylinder connection (4).

E)Hose to regulator connection (5).

F)Valves to manifold connections (6).

WARNING: If there is a leak at connections (4, 5 or 6), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site.

Log onto www.weber.com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

REFILLING THE LIQUID PROPANE CYLINDER

We recommend that you refill the LP cylinder before it is completely empty.

Removal of the LP cylinder

A)Close cylinder valve (turn clockwise) (1).

B)Unscrew regulator coupling by turning counterclockwise, by hand only (2).

C)Loosen cylinder lock wing nut and turn cylinder lock up out of the way.

D)Lift cylinder off.

To fill, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in the phone book for other sources of LP gas.

WARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualified attendant,

who fills the cylinder by weight. IMPROPER FILLING IS DANGEROUS.

CAUTION: Place dust cap on cylinder valve outlet whenever 3 the cylinder is not in use. Only install the type of dust cap

on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

320

* The grill illustrated may have slight differences than the model purchased.

2

1

4

5

6

1

2

CHECKING THE FUEL LEVEL IN YOUR TANK

1

2

3

Check the fuel level by viewing the color indicator level line on the side of the tank scale.

A) Empty (1)

B) Medium (2)

C) Full (3)

12

Image 12
Contents GAS Grill Wash hands after handling this product Liquid Propane GAS Units onlyWARRANTY, GARANTÍA, Garantie USAExploded View Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée Exploded View ListGenesis320LPUS2010 Side Burner Table For Installation in Canada CleaningGeneral Instructions Operating Storage AND/OR NonuseConnecting the Liquid Propane Cylinder GAS InstructionsImportant LP Cylinder Information Leak Check PreparationTo connect the hose to the cylinder Remove Control Knobs & Control Panel for Leak Testing Check for GAS LeaksRefilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankOperating Instructions Safe Handling Tips for Liquid Propane GAS CylindersCanada LightingMain Burner Lighting To ExtinguishMain Burner Manual Lighting Lighting the Side Burner To Extinguish320 Manually Lighting the Side BurnerTroubleshooting Side Burner TroubleshootingProblem Check Cure Side Burner Maintenance MaintenanceSide Burner Maintenance Weber SPIDER/INSECT ScreensAnnual Maintenance Main Burner Cleaning ProcedureInspection and Cleaning of the SPIDER/INSECT Screens Burner Flame PatternReplace Battery if Necessary Crossover Ignition System OperationsPage Page Barbacoa DE GAS Peligro AdvertenciasÚnicamente Unidades DE GAS Propano Licuado Instrucciones Generales Instrucciones Sobre EL GAS Preparativos Para LA Búsqueda DE FugasCómo Conectar EL Cilindro DE Propano Licuado Para Conectar LA Manguera AL Cilindro Compruebe QUE no Haya Fugas DE GAS Peligro Usted necesitará un destornillador PhillipsCómo Recargar EL Cilindro DE Propano Licuado Cómo Verificar EL Nivel DE Combustible EN SU TanqueInstrucciones DE Operación EN CanadáEncendido Encendido DEL Quemador Principal Encendido Manual DEL Quemador Principal PeligroPara Apagar Cómo Encender EL Quemador Lateral Peligro Encendido Manual DEL Quemador Lateral Peligro Resolución DE Problemas Resolución DE Problemas DEL Quemador LateralProblema Revisar Remedio Mantenimiento DEL Quemador Lateral MantenimientoMantenimiento DEL Quemador Lateral Mallas Weber Contra Arañas E InsectosMantenimiento Anual Patrón DE LA Llama DEL QuemadorProcedimiento Para LA Limpieza DEL Quemador Principal Reemplazo DE LOS Quemadores PrincipalesOperación DEL Sistema DE Encendido Crossover Reemplace LA Batería SI Fuese NecesarioPage Grill a GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Generalites Instructions Relatives AU GAZ Informations Importantes Relatives a LA Bouteille DE PLPreparation DE LA Detection DES Fuites Verifiez QUE Toutes LES Valves DES Bruleurs Sont FermeesPour connecter le tuyau à la bouteille de gaz Detection DES Fuites DE GAZ Il vous faudra un tournevis cruciformeRechargement DE LA Bouteille DE Propane Liquide Aiguilles d’une montre, à la main uniquementInstructions Relatives a L’UTILISATION Bouteilles DE GAZ Propane Liquide PLExigences Relatives À LA Bouteille DE Propane Liquide AU CanadaAllumage DU Bruleur Principal Allumage Manuel DU Bruleur PrincipalPour Eteindre Allumage DU Bruleur Lateral Pour EteindreAllumage Manuel DU Bruleur Lateral Probleme Verification Solution DepannageDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGrilles ANTI-ARAIGNEES/INSECTES Weber Maintenance Annuelle Procedure DE Nettoyage DU Bruleur PrincipalRemplacement DES Bruleurs Principaux Aspect DES Flammes DU BrûleurOperations DU Systeme D’ALLUMAGE Crossover Remplacez LA Pile SI NecessairePage Page WEBER-STEPHEN Products CO