Weber 89478 manual Lighting the Side Burner, To Extinguish

Page 15

OPERATING INSTRUCTIONS

DANGER

When the “excess gas flow control” feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame-up, which can cause serious bodily injury or death.

C)Turn the cylinder on by turning the cylinder valve counterclockwise (3).

D)Insert match holder with lit match into the matchlight hole in the front of the cooking box (4).

WARNING: Do not lean over open barbecue. Keep your face and body at least one foot away from the matchlight hole when lighting the barbecue.

E)Push BURNER 1 control knob down and turn to START/HI (5).

F)Check that the burner is lit by looking through the matchlight hole on the front of the cooking box. You should see a flame (6).

WARNING: If the burner does not light in five seconds, turn the Burner 1 control knob to OFF and wait 5 minutes to let the gas clear before you try again.

G)After BURNER 1 is lit you can turn on BURNER 2 (and BURNER 3) (7). Note - Always light BURNER 1 first.The other burners ignite from BURNER 1.

TO EXTINGUISH

Push down and turn each burner control knob clockwise to the OFF position. Turn gas supply OFF at the source.

LIGHTING THE SIDE BURNER

 

 

 

 

2

 

 

 

 

 

FF

A

P

 

 

 

 

/O

 

A

 

 

 

E

 

 

G

 

 

 

 

 

A

 

 

 

T

 

 

D

 

 

R

E

 

 

O

A

R

 

 

 

 

1

 

 

 

 

 

 

5

*The grill illustrated may have slight differences than the model purchased.

1

2

4 67

3 5

DANGER

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flame-up which can cause serious bodily injury or death.

WARNING: Check hose before each use of barbecue for nicks, cracking, abrasions or cuts. If the hose is found to be damaged in any way, do not use the barbecue. Replace using only Weber® authorized replacement hose. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber. com®.

A)Open the side burner lid (1).

B)Check that the side burner valve is turned off (2) (Push control knob in and turn clockwise to ensure that it is in the “OFF” position), turn all burners not being used to the “OFF” position (push in and turn clockwise).

WARNING: The burner control knobs must be in the OFF position before turning on the liquid propane cylinder valve. If they are not in the OFF position, when you turn on the LP cylinder valve, the “excess gas flow control” feature will activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Start over.

320

1

2

2 4

3 5

DANGER

When the “excess gas flow control” feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame-up, which can cause serious bodily injury or death.

WWW.WEBER.COM® 15

Image 15
Contents GAS Grill Liquid Propane GAS Units only Wash hands after handling this productUSA WARRANTY, GARANTÍA, GarantieExploded View Exploded View List Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision ÉclatéeGenesis320LPUS2010 Side Burner Table Operating Storage AND/OR Nonuse For Installation in CanadaCleaning General InstructionsLeak Check Preparation Connecting the Liquid Propane CylinderGAS Instructions Important LP Cylinder InformationTo connect the hose to the cylinder Check for GAS Leaks Remove Control Knobs & Control Panel for Leak TestingChecking the Fuel Level in Your Tank Refilling the Liquid Propane CylinderLighting Operating InstructionsSafe Handling Tips for Liquid Propane GAS Cylinders CanadaMain Burner Lighting To ExtinguishMain Burner Manual Lighting To Extinguish Lighting the Side BurnerManually Lighting the Side Burner 320Troubleshooting Side Burner TroubleshootingProblem Check Cure Weber SPIDER/INSECT Screens Side Burner MaintenanceMaintenance Side Burner MaintenanceBurner Flame Pattern Annual MaintenanceMain Burner Cleaning Procedure Inspection and Cleaning of the SPIDER/INSECT ScreensCrossover Ignition System Operations Replace Battery if NecessaryPage Page Barbacoa DE GAS Peligro AdvertenciasÚnicamente Unidades DE GAS Propano Licuado Instrucciones Generales Instrucciones Sobre EL GAS Preparativos Para LA Búsqueda DE FugasCómo Conectar EL Cilindro DE Propano Licuado Para Conectar LA Manguera AL Cilindro Usted necesitará un destornillador Phillips Compruebe QUE no Haya Fugas DE GAS PeligroCómo Verificar EL Nivel DE Combustible EN SU Tanque Cómo Recargar EL Cilindro DE Propano LicuadoInstrucciones DE Operación EN CanadáEncendido Encendido DEL Quemador Principal Encendido Manual DEL Quemador Principal PeligroPara Apagar Cómo Encender EL Quemador Lateral Peligro Encendido Manual DEL Quemador Lateral Peligro Resolución DE Problemas Resolución DE Problemas DEL Quemador LateralProblema Revisar Remedio Mallas Weber Contra Arañas E Insectos Mantenimiento DEL Quemador LateralMantenimiento Mantenimiento DEL Quemador LateralReemplazo DE LOS Quemadores Principales Mantenimiento AnualPatrón DE LA Llama DEL Quemador Procedimiento Para LA Limpieza DEL Quemador PrincipalReemplace LA Batería SI Fuese Necesario Operación DEL Sistema DE Encendido CrossoverPage Grill a GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Generalites Verifiez QUE Toutes LES Valves DES Bruleurs Sont Fermees Instructions Relatives AU GAZInformations Importantes Relatives a LA Bouteille DE PL Preparation DE LA Detection DES FuitesPour connecter le tuyau à la bouteille de gaz Il vous faudra un tournevis cruciforme Detection DES Fuites DE GAZAiguilles d’une montre, à la main uniquement Rechargement DE LA Bouteille DE Propane LiquideAU Canada Instructions Relatives a L’UTILISATIONBouteilles DE GAZ Propane Liquide PL Exigences Relatives À LA Bouteille DE Propane LiquideAllumage DU Bruleur Principal Allumage Manuel DU Bruleur PrincipalPour Eteindre Pour Eteindre Allumage DU Bruleur LateralAllumage Manuel DU Bruleur Lateral Probleme Verification Solution DepannageDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGrilles ANTI-ARAIGNEES/INSECTES Weber Aspect DES Flammes DU Brûleur Maintenance AnnuelleProcedure DE Nettoyage DU Bruleur Principal Remplacement DES Bruleurs PrincipauxRemplacez LA Pile SI Necessaire Operations DU Systeme D’ALLUMAGE CrossoverPage Page WEBER-STEPHEN Products CO