Weber 89478 manual 320, Manually Lighting the Side Burner

Page 16

OPERATING INSTRUCTIONS

C)Turn the gas supply valve on (3).

D)Push down and turn the side burner control valve to “HI” (4).

E)Press the igniter button several times so it clicks each time (5).

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light in five (5) seconds:

a)Turn off the side burner control valve, main burners and gas supply at source.

b)Wait 5 minutes to let the gas clear before you try again, or try lighting with a match (see “Manually Lighting the Side Burner”).

320

1

2 2 4

3

5

MANUALLY LIGHTING THE SIDE BURNER

DANGER

320

Failure to open the lid while igniting the side burner, or not waiting 5 minutes to allow the gas to clear if the side burner does not light, may result in an explosive flare-up that can cause serious bodily injury or death.

A) Open the side burner lid (1).

1

2

B) Check that the side burner valve is turned off (2) (Push control knob in and turn

clockwise to ensure that it is in the “OFF” position), turn all burners not being used

 

 

to the “OFF” position (push in and turn clockwise).

 

 

WARNING: The burner control knobs must be in the OFF

2

6

position before turning on the liquid propane cylinder valve.

4 5

 

If they are not in the OFF position, when you turn on the

3

LP cylinder valve, the “excess gas flow control” feature will

 

activate, limiting the flow of gas from the LP cylinder. If this should occur, turn OFF the LP tank valve and burner control knobs. Start over.

DANGER

When the “excess gas flow control” feature is activated, a small amount of gas is still flowing to the burners. After turning OFF the cylinder and burner control knobs, wait at least 5 minutes for the gas to clear before attempting to light the barbecue. Failure to do so may result in an explosive flame-up, which can cause serious bodily injury or death.

C)Turn the gas supply valve on (3).

D)Put match in a match holder and strike match (4).

E)Hold match holder and lit match by either side of the side burner (5).

F)Push down and turn the side burner control valve to “HI” (6).

CAUTION: Side burner flame may be difficult to see on a bright sunny day.

WARNING: If the side burner does not light in five (5) seconds:

a)Turn off the side burner control valve, main burners and gas supply at source.

b)Wait 5 minutes to let the gas clear before you try again.

16

Image 16
Contents GAS Grill Wash hands after handling this product Liquid Propane GAS Units onlyWARRANTY, GARANTÍA, Garantie USAExploded View Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée Exploded View ListGenesis320LPUS2010 Side Burner Table For Installation in Canada CleaningGeneral Instructions Operating Storage AND/OR NonuseConnecting the Liquid Propane Cylinder GAS InstructionsImportant LP Cylinder Information Leak Check PreparationTo connect the hose to the cylinder Remove Control Knobs & Control Panel for Leak Testing Check for GAS LeaksRefilling the Liquid Propane Cylinder Checking the Fuel Level in Your Tank Operating Instructions Safe Handling Tips for Liquid Propane GAS Cylinders Canada LightingTo Extinguish Main Burner LightingMain Burner Manual Lighting Lighting the Side Burner To Extinguish320 Manually Lighting the Side BurnerSide Burner Troubleshooting TroubleshootingProblem Check Cure Side Burner Maintenance MaintenanceSide Burner Maintenance Weber SPIDER/INSECT ScreensAnnual Maintenance Main Burner Cleaning ProcedureInspection and Cleaning of the SPIDER/INSECT Screens Burner Flame PatternReplace Battery if Necessary Crossover Ignition System OperationsPage Page Barbacoa DE GAS Advertencias PeligroÚnicamente Unidades DE GAS Propano Licuado Instrucciones Generales Preparativos Para LA Búsqueda DE Fugas Instrucciones Sobre EL GASCómo Conectar EL Cilindro DE Propano Licuado Para Conectar LA Manguera AL Cilindro Compruebe QUE no Haya Fugas DE GAS Peligro Usted necesitará un destornillador PhillipsCómo Recargar EL Cilindro DE Propano Licuado Cómo Verificar EL Nivel DE Combustible EN SU TanqueEN Canadá Instrucciones DE OperaciónEncendido Encendido Manual DEL Quemador Principal Peligro Encendido DEL Quemador PrincipalPara Apagar Cómo Encender EL Quemador Lateral Peligro Encendido Manual DEL Quemador Lateral Peligro Resolución DE Problemas DEL Quemador Lateral Resolución DE ProblemasProblema Revisar Remedio Mantenimiento DEL Quemador Lateral MantenimientoMantenimiento DEL Quemador Lateral Mallas Weber Contra Arañas E InsectosMantenimiento Anual Patrón DE LA Llama DEL QuemadorProcedimiento Para LA Limpieza DEL Quemador Principal Reemplazo DE LOS Quemadores PrincipalesOperación DEL Sistema DE Encendido Crossover Reemplace LA Batería SI Fuese NecesarioPage Grill a GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Generalites Instructions Relatives AU GAZ Informations Importantes Relatives a LA Bouteille DE PLPreparation DE LA Detection DES Fuites Verifiez QUE Toutes LES Valves DES Bruleurs Sont FermeesPour connecter le tuyau à la bouteille de gaz Detection DES Fuites DE GAZ Il vous faudra un tournevis cruciformeRechargement DE LA Bouteille DE Propane Liquide Aiguilles d’une montre, à la main uniquementInstructions Relatives a L’UTILISATION Bouteilles DE GAZ Propane Liquide PLExigences Relatives À LA Bouteille DE Propane Liquide AU CanadaAllumage Manuel DU Bruleur Principal Allumage DU Bruleur PrincipalPour Eteindre Allumage DU Bruleur Lateral Pour EteindreAllumage Manuel DU Bruleur Lateral Depannage Probleme Verification SolutionDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGrilles ANTI-ARAIGNEES/INSECTES Weber Maintenance Annuelle Procedure DE Nettoyage DU Bruleur PrincipalRemplacement DES Bruleurs Principaux Aspect DES Flammes DU BrûleurOperations DU Systeme D’ALLUMAGE Crossover Remplacez LA Pile SI NecessairePage Page WEBER-STEPHEN Products CO