Weber 89478 manual Annual Maintenance, Burner Flame Pattern, Main Burner Cleaning Procedure

Page 19

MAINTENANCE

ANNUAL MAINTENANCE

INSPECTION AND CLEANING OF THE SPIDER/INSECT SCREENS

To inspect the Spider/Insect screens, remove the control panel. If there is dust or dirt on the screens, remove the burners for cleaning the screens.

Brush the Spider/Insect screens lightly with a soft bristle brush (i.e. an old toothbrush).

CAUTION: Do not clean the Spider/Insect screens with hard or sharp tools. Do not dislodge the Spider/Insect screens or enlarge the screen openings.

Lightly tap the burner to get debris and dirt out of the burner tube. Once the Spider/ Insect screens and burners are clean replace the burners.

If the Spider/Insect screen becomes damaged or cannot be cleaned, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

BURNER FLAME PATTERN

The Weber® gas barbecue burners have been factory set for the correct air and gas mixture. The correct flame pattern is shown.

A)Burner tube (1)

B)Tips occasionally flicker yellow (2)

C)Light blue (3)

D)Dark blue (4)

If the flames do not appear to be uniform throughout the burner tube, follow the burner cleaning procedures.

MAIN BURNER CLEANING PROCEDURE

TURN OFF THE GAS SUPPLY.

Remove the manifold (See “Replacing Main Burners”).

Look inside each burner with a flashlight.

Clean the inside of the burners with a wire (a straightened-out coat hanger will work). Check and clean the air shutter opening at the ends of the burners. Check and clean the valve orifices at the base of the valves. Use a Steel bristle brush to clean outside of burners. This is to make sure all the burner ports are fully open.

CAUTION: Do not enlarge the burner ports when cleaning.

REPLACING MAIN BURNERS

A) Your Weber® gas barbecue must be OFF and cool.

B) Turn gas OFF at source.

C) To remove control panel:

(a) Take off the burner control knobs (1).

(b)Remove screw and washer from back of control panel with a Phillips screwdriver

(2).

(c)Tilt the back edge of the control panel up. Push in on the front edge to release locking tabs (3).

(d)Disconnect the igniter wires from the ignition module (4).

(e) Carefully pull control panel away from frame (5).

1

2

3

4

1

2

5

3

4

WWW.WEBER.COM® 19

Image 19
Contents GAS Grill Liquid Propane GAS Units only Wash hands after handling this productUSA WARRANTY, GARANTÍA, GarantieExploded View Exploded View List Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision ÉclatéeGenesis320LPUS2010 Side Burner Table Operating Storage AND/OR Nonuse For Installation in CanadaCleaning General InstructionsLeak Check Preparation Connecting the Liquid Propane CylinderGAS Instructions Important LP Cylinder InformationTo connect the hose to the cylinder Check for GAS Leaks Remove Control Knobs & Control Panel for Leak TestingChecking the Fuel Level in Your Tank Refilling the Liquid Propane CylinderLighting Operating InstructionsSafe Handling Tips for Liquid Propane GAS Cylinders CanadaTo Extinguish Main Burner LightingMain Burner Manual Lighting To Extinguish Lighting the Side BurnerManually Lighting the Side Burner 320Side Burner Troubleshooting TroubleshootingProblem Check Cure Weber SPIDER/INSECT Screens Side Burner MaintenanceMaintenance Side Burner MaintenanceBurner Flame Pattern Annual MaintenanceMain Burner Cleaning Procedure Inspection and Cleaning of the SPIDER/INSECT ScreensCrossover Ignition System Operations Replace Battery if NecessaryPage Page Barbacoa DE GAS Advertencias PeligroÚnicamente Unidades DE GAS Propano Licuado Instrucciones Generales Preparativos Para LA Búsqueda DE Fugas Instrucciones Sobre EL GASCómo Conectar EL Cilindro DE Propano Licuado Para Conectar LA Manguera AL Cilindro Usted necesitará un destornillador Phillips Compruebe QUE no Haya Fugas DE GAS PeligroCómo Verificar EL Nivel DE Combustible EN SU Tanque Cómo Recargar EL Cilindro DE Propano LicuadoEN Canadá Instrucciones DE OperaciónEncendido Encendido Manual DEL Quemador Principal Peligro Encendido DEL Quemador PrincipalPara Apagar Cómo Encender EL Quemador Lateral Peligro Encendido Manual DEL Quemador Lateral Peligro Resolución DE Problemas DEL Quemador Lateral Resolución DE ProblemasProblema Revisar Remedio Mallas Weber Contra Arañas E Insectos Mantenimiento DEL Quemador LateralMantenimiento Mantenimiento DEL Quemador LateralReemplazo DE LOS Quemadores Principales Mantenimiento AnualPatrón DE LA Llama DEL Quemador Procedimiento Para LA Limpieza DEL Quemador PrincipalReemplace LA Batería SI Fuese Necesario Operación DEL Sistema DE Encendido CrossoverPage Grill a GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Generalites Verifiez QUE Toutes LES Valves DES Bruleurs Sont Fermees Instructions Relatives AU GAZInformations Importantes Relatives a LA Bouteille DE PL Preparation DE LA Detection DES FuitesPour connecter le tuyau à la bouteille de gaz Il vous faudra un tournevis cruciforme Detection DES Fuites DE GAZAiguilles d’une montre, à la main uniquement Rechargement DE LA Bouteille DE Propane LiquideAU Canada Instructions Relatives a L’UTILISATIONBouteilles DE GAZ Propane Liquide PL Exigences Relatives À LA Bouteille DE Propane LiquideAllumage Manuel DU Bruleur Principal Allumage DU Bruleur PrincipalPour Eteindre Pour Eteindre Allumage DU Bruleur LateralAllumage Manuel DU Bruleur Lateral Depannage Probleme Verification SolutionDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGrilles ANTI-ARAIGNEES/INSECTES Weber Aspect DES Flammes DU Brûleur Maintenance AnnuelleProcedure DE Nettoyage DU Bruleur Principal Remplacement DES Bruleurs PrincipauxRemplacez LA Pile SI Necessaire Operations DU Systeme D’ALLUMAGE CrossoverPage Page WEBER-STEPHEN Products CO