SIDE BURNER MAINTENANCE

SIDE BURNER MAINTENANCE

WARNING: All gas controls and supply valves should be in the “OFF” position.

Make sure black wire is connected between the igniter and electrode.

Make sure white wire is connected between the igniter and grounding clip.

Spark should be a white/blue color, not yellow.

A)Igniter Wire (1)

B)Ground wire (2)

C)Burner (3)

Side Burner Grate

Side Burner cap

Side Burner Ring & Head

Igniter Electrode

Control Knob

Igniter

3

2

1

1

2

MAINTENANCE

WEBER® SPIDER/INSECT SCREENS

Your Weber® gas barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section (1) of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the combustion air opening. This could result in a fire in and around the combustion air openings, under the control panel, causing serious damage to your barbecue.

The burner tube combustion air opening is fitted with a stainless steel screen (2) to prevent spiders and other insects access to the burner tubes through the combustion air openings.

We recommend that you inspect the Spider/Insect screens at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the the Spider/Insect screens if any of the following symptoms should ever occur:

A)The smell of gas in conjunction with the burner flames appearing yellow and lazy.

B)Barbecue does not reach temperature.

C)Barbecue heats unevenly.

D)One or more of the burners do not ignite.

DANGER

1

2

Failure to correct the above mentioned symptoms may result in a fire, which can cause serious bodily injury or death, and cause damage to property.

18

Image 18
Contents GAS Grill Wash hands after handling this product Liquid Propane GAS Units onlyWARRANTY, GARANTÍA, Garantie USAExploded View Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée Exploded View ListGenesis320LPUS2010 Side Burner Table General Instructions For Installation in CanadaCleaning Operating Storage AND/OR NonuseImportant LP Cylinder Information Connecting the Liquid Propane CylinderGAS Instructions Leak Check PreparationTo connect the hose to the cylinder Remove Control Knobs & Control Panel for Leak Testing Check for GAS LeaksRefilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankCanada Operating InstructionsSafe Handling Tips for Liquid Propane GAS Cylinders LightingMain Burner Lighting To ExtinguishMain Burner Manual Lighting Lighting the Side Burner To Extinguish320 Manually Lighting the Side BurnerTroubleshooting Side Burner TroubleshootingProblem Check Cure Side Burner Maintenance Side Burner MaintenanceMaintenance Weber SPIDER/INSECT ScreensInspection and Cleaning of the SPIDER/INSECT Screens Annual MaintenanceMain Burner Cleaning Procedure Burner Flame PatternReplace Battery if Necessary Crossover Ignition System OperationsPage Page Barbacoa DE GAS Peligro AdvertenciasÚnicamente Unidades DE GAS Propano Licuado Instrucciones Generales Instrucciones Sobre EL GAS Preparativos Para LA Búsqueda DE FugasCómo Conectar EL Cilindro DE Propano Licuado Para Conectar LA Manguera AL Cilindro Compruebe QUE no Haya Fugas DE GAS Peligro Usted necesitará un destornillador PhillipsCómo Recargar EL Cilindro DE Propano Licuado Cómo Verificar EL Nivel DE Combustible EN SU TanqueInstrucciones DE Operación EN CanadáEncendido Encendido DEL Quemador Principal Encendido Manual DEL Quemador Principal PeligroPara Apagar Cómo Encender EL Quemador Lateral Peligro Encendido Manual DEL Quemador Lateral Peligro Resolución DE Problemas Resolución DE Problemas DEL Quemador LateralProblema Revisar Remedio Mantenimiento DEL Quemador Lateral Mantenimiento DEL Quemador LateralMantenimiento Mallas Weber Contra Arañas E InsectosProcedimiento Para LA Limpieza DEL Quemador Principal Mantenimiento AnualPatrón DE LA Llama DEL Quemador Reemplazo DE LOS Quemadores PrincipalesOperación DEL Sistema DE Encendido Crossover Reemplace LA Batería SI Fuese NecesarioPage Grill a GAZ Mises EN Garde Mises EN GardeAppareils a GAZ Propane Uniquement Generalites Preparation DE LA Detection DES Fuites Instructions Relatives AU GAZInformations Importantes Relatives a LA Bouteille DE PL Verifiez QUE Toutes LES Valves DES Bruleurs Sont FermeesPour connecter le tuyau à la bouteille de gaz Detection DES Fuites DE GAZ Il vous faudra un tournevis cruciformeRechargement DE LA Bouteille DE Propane Liquide Aiguilles d’une montre, à la main uniquementExigences Relatives À LA Bouteille DE Propane Liquide Instructions Relatives a L’UTILISATIONBouteilles DE GAZ Propane Liquide PL AU CanadaAllumage DU Bruleur Principal Allumage Manuel DU Bruleur PrincipalPour Eteindre Allumage DU Bruleur Lateral Pour EteindreAllumage Manuel DU Bruleur Lateral Probleme Verification Solution DepannageDepannage DU Bruleur Lateral Maintenance DU Bruleur Lateral Maintenance DU Bruleur LateralGrilles ANTI-ARAIGNEES/INSECTES Weber Remplacement DES Bruleurs Principaux Maintenance AnnuelleProcedure DE Nettoyage DU Bruleur Principal Aspect DES Flammes DU BrûleurOperations DU Systeme D’ALLUMAGE Crossover Remplacez LA Pile SI NecessairePage Page WEBER-STEPHEN Products CO