Weber E/S-320 manual Refilling the Liquid Propane Cylinder, Checking the Fuel Level in Your Tank

Page 12

12

GAS INSTRUCTIONS

Check:

1) Hose to manifold connection.

2) Side burner hose to manifold connection and side burner hose to side burner gas line connection.

3) Side burner hose to side burner connection, side burner valve and orifi ce connections.

WARNING: If there is a leak at connection (1, 2, or 3), retighten the fitting with a wrench and recheck for leaks with soap and water solution. If a leak persists after re-tightening the fitting, turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www. weber.com®.

4)Regulator to cylinder connection.

5)Hose to regulator connection.

6) Valves to manifold connections.

WARNING: If there is a leak at connections (4, 5 or 6), turn OFF the gas. DO NOT OPERATE THE GRILL. Contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber. com®.

When leak checks are complete, turn gas supply OFF at the source and rinse connections with water.

REFILLING THE LIQUID PROPANE CYLINDER

We recommend that you refi ll the LP cylinder before it is completely empty. Removal of the LP cylinder

1) Close cylinder valve (turn clockwise).

2) Unscrew regulator coupling by turning counterclockwise, by hand only.

3)Loosen cylinder lock wing nut and turn cylinder lock up out of the way.

4)Lift cylinder off.

To fi ll, take the LP cylinder to a gas propane dealer, or look up “gas-propane” in the phone book for other sources of LP gas.

WARNING: We recommend that your LP cylinder be filled at an authorized LP gas dealer, by a qualified attendant, who fills the cylinder by weight. IMPROPER FILLING IS DANGEROUS.

CAUTION: Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

(3)

(1)

 

(2)

320

*The grill illustrated may have slight differences than the model purchased.

CHECKING THE FUEL LEVEL IN YOUR TANK

Check the fuel level by viewing the color indicator level line on the side of the tank scale.

1)Empty

2)Medium

3)Full

(1)

(2)

(3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WWW.WEBER.COM®

Image 12
Contents GAS Grill 2WARNINGS WARRANTY, GARANTÍA, Garantie Customer Service Center Roselle Road, Suite Schaumburg, ILFor replacement parts call Para partes de repuesto llame aExploded View E/S/EP Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée Exploded View List E/S/EP$ $ Side Burner Table For Installation in Canada CleaningGeneral Instructions Operating Storage AND/OR NonuseConnecting the Liquid Propane Cylinder GAS InstructionsImportant LP Cylinder Information Leak Check Preparation Check That ALL Burner Valves are OFFTo Connect the hose to the cylinder Turn on the cylinder valveGAS Instructions Refilling the Liquid Propane Cylinder Checking the Fuel Level in Your TankOperating Instructions LightingSafe Handling Tips for Liquid Propane GAS Cylinders Liquid Propane LP CylindersMain Burner Lighting Main Burner Manual LightingMain Burner Lighting To ExtinguishTo Extinguish Lighting the Side BurnerTroubleshooting Problem Check CureManually Lighting the Side Burner Side Burner Troubleshooting Side Burner MaintenanceMaintenance Side Burner Maintenance18MAINTENANCE Main Burner Cleaning ProcedureReplacing Main Burners Main Burner Flame PatternReplace Battery if Necessary Crossover Ignition System OperationsBarbacoa DE GAS ADVERTENCIAS21 Instrucciones Generales Instrucciones Sobre EL GAS Información Importante Sobre EL Cilindro DE Propano LicuadoPreparativos Para LA Búsqueda DE Fugas Cómo Conectar EL Cilindro DE Propano LicuadoPara conectar la manguera al cilindro Compruebe QUE no Haya Fugas DE GAS Usted necesitará un destornillador PhillipsCómo Recargar EL Cilindro DE Propano Licuado Cómo Verificar EL Nivel DE Combustible EN SU TanqueInstrucciones DE Operación EncendidoCilindros de propano licuado Encendido DEL Quemador Principal Encendido Manual DEL Quemador PrincipalEncendido DEL Quemador Principal Para ApagarPara Apagar Cómo Encender EL Quemador LateralResolución DE Problemas Problema Revisar RemedioEncendido Manual DEL Quemador Lateral Resolución DE Problemas DEL Quemador Lateral Mantenimiento DEL Quemador LateralMantenimiento Mantenimiento DEL Quemador Lateral32MANTENIMIENTO Mantenimiento AnualPatrón DE LA Llama DEL Quemador Principal Procedimiento Para LA Limpieza DEL Quemador PrincipalOperación DEL Sistema DE Encendido Crossover Reemplace LA Batería SI Fuese NecesarioGrill a GAZ Mises EN Garde Mises EN Garde36GENERALITES GENERALITES37 Instructions Relatives AU GAZInformations IMP0ORTANTES Relatives a LA Bouteille DE PL Preparation DE LA Detection DES FuitesPour connecter le tuyau à la bouteille de gaz Detection DES Fuites DE GAZ Il vous faudra un tournevis cruciformeRechargement DE LA Bouteille DE Propane Liquide Verification DU Niveau DE Combustible Dans Votre BouteilleInstructions Relatives a L’UTILISATION AllumageBouteilles de gaz propane liquide PL Allumage Manuel DU Bruleur Principal Allumage DU Bruleur PrincipalPour Eteindre Pour Eteindre Allumage DU Bruleur LateralProbleme Verification Solution DepannageAllumage Manuel DU Bruleur Lateral Maintenance DU Bruleur Lateral Probleme VerificationMaintenance DU Bruleur Lateral Depannage DU Bruleur Lateral46MAINTENANCE Maintenance AnnuelleProcedure DE Nettoyage DU Bruleur Principal Remplacement DES Bruleurs PrincipauxOperations DU Systeme D’ALLUMAGE Crossover Remplacez LA Pile SI NecessairePage Page Page Page Page Page WEBER-STEPHEN Products CO Month / MES / Mois DAY / DÍA / Jour For purchases made in the U.S