SIDE BURNER TROUBLESHOOTING

17

 

 

 

 

 

 

 

 

PROBLEM

CHECK

CURE

 

 

 

 

 

Side Burner does not light.

Is gas supply off?

Turn supply on.

 

 

The excess fl ow safety device, which is part

To reset the excess fl ow safety device turn all burner control knobs and the cylinder

 

of the barbecue to cylinder connection, may

valve off. Disconnect the regulator from the cylinder. Turn burner control knobs to

 

have activated.

START/HI. Wait at least 1 minute. Turn burner control knobs to “OFF”. Reconnect

 

 

the regulator to the cylinder. Turn cylinder valve on slowly. Refer to “Lighting Instruc-

 

 

tions”.

 

 

 

 

 

Flame is low in “HI” position.

Is the fuel hose bent or kinked?

Straighten hose.

 

 

 

 

 

Push button ignition does not work.

Does burner light with a match?

If match lights burner, check igniter (see Sideburner Maintenance).

 

 

 

 

 

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web site. Log onto www.weber.com®.

SIDE BURNER MAINTENANCE

SIDE BURNER MAINTENANCE

WARNING: All gas controls and supply valves should be in the “OFF” position.

Make sure black wire is connected between the igniter and electrode. Make sure white wire is connected between the igniter and grounding clip. Spark should be a white/blue color, not yellow.

1)Igniter Wire

2)Ground wire

3)Burner

(3)

(1)

(2)

Side Burner Grate

Burner Grate

Side Burner cap

e Cap

Side Burner Ringr & Head

IgniteriterElectrode

ControlKnob

Igniter Button

Igniter

(1)

(2)

MAINTENANCE

WEBER® SPIDER /INSECT SCREENS

Your Weber® gas barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section (1) of the burner tubes. This blocks the normal gas fl ow, and can cause the gas to flow back out of the combustion air opening. This could result in a fi re in and around the combustion air openings, under the control panel, causing serious damage to your barbecue.

The burner tube combustion air opening is fi tted with a stainless steel screen (2) to prevent spiders and other insects access to the burner tubes through the combustion air openings.

We recommend that you inspect the Spider/Insect screens at least once a year. (See Section “Annual Maintenance”.) Also inspect and clean the the Spider/Insect screens if any of the following symptoms should ever occur:

1)The smell of gas in conjunction with the burner fl ames appearing yellow and lazy.

2)Barbecue does not reach temperature.

3)Barbecue heats unevenly.

4)One or more of the burners do not ignite.

DANGER

Failure to correct the above mentioned symptoms may result in a fire, which can cause serious bodily injury or death, and cause damage to property.

1

2

WWW.WEBER.COM®

Image 17
Contents GAS Grill 2WARNINGS Customer Service Center Roselle Road, Suite Schaumburg, IL WARRANTY, GARANTÍA, GarantieFor replacement parts call Para partes de repuesto llame aExploded View E/S/EP Exploded View List E/S/EP Lista DEL Diagrama DE DESPIECE, Liste DE LA Vision Éclatée$ $ Side Burner Table Cleaning For Installation in CanadaGeneral Instructions Operating Storage AND/OR NonuseGAS Instructions Connecting the Liquid Propane CylinderImportant LP Cylinder Information Leak Check Preparation Check That ALL Burner Valves are OFFTurn on the cylinder valve To Connect the hose to the cylinderGAS Instructions Checking the Fuel Level in Your Tank Refilling the Liquid Propane CylinderLighting Operating InstructionsSafe Handling Tips for Liquid Propane GAS Cylinders Liquid Propane LP CylindersMain Burner Manual Lighting Main Burner LightingMain Burner Lighting To ExtinguishLighting the Side Burner To ExtinguishManually Lighting the Side Burner TroubleshootingProblem Check Cure Side Burner Maintenance Side Burner TroubleshootingMaintenance Side Burner MaintenanceMain Burner Cleaning Procedure 18MAINTENANCEReplacing Main Burners Main Burner Flame PatternCrossover Ignition System Operations Replace Battery if NecessaryBarbacoa DE GAS ADVERTENCIAS21 Instrucciones Generales Información Importante Sobre EL Cilindro DE Propano Licuado Instrucciones Sobre EL GASPreparativos Para LA Búsqueda DE Fugas Cómo Conectar EL Cilindro DE Propano LicuadoPara conectar la manguera al cilindro Usted necesitará un destornillador Phillips Compruebe QUE no Haya Fugas DE GASCómo Verificar EL Nivel DE Combustible EN SU Tanque Cómo Recargar EL Cilindro DE Propano LicuadoCilindros de propano licuado Instrucciones DE OperaciónEncendido Encendido Manual DEL Quemador Principal Encendido DEL Quemador PrincipalEncendido DEL Quemador Principal Para ApagarCómo Encender EL Quemador Lateral Para ApagarEncendido Manual DEL Quemador Lateral Resolución DE ProblemasProblema Revisar Remedio Mantenimiento DEL Quemador Lateral Resolución DE Problemas DEL Quemador LateralMantenimiento Mantenimiento DEL Quemador LateralMantenimiento Anual 32MANTENIMIENTOPatrón DE LA Llama DEL Quemador Principal Procedimiento Para LA Limpieza DEL Quemador PrincipalReemplace LA Batería SI Fuese Necesario Operación DEL Sistema DE Encendido CrossoverGrill a GAZ Mises EN Garde Mises EN Garde36GENERALITES Instructions Relatives AU GAZ GENERALITES37Informations IMP0ORTANTES Relatives a LA Bouteille DE PL Preparation DE LA Detection DES FuitesPour connecter le tuyau à la bouteille de gaz Il vous faudra un tournevis cruciforme Detection DES Fuites DE GAZVerification DU Niveau DE Combustible Dans Votre Bouteille Rechargement DE LA Bouteille DE Propane LiquideBouteilles de gaz propane liquide PL Instructions Relatives a L’UTILISATIONAllumage Pour Eteindre Allumage Manuel DU Bruleur PrincipalAllumage DU Bruleur Principal Allumage DU Bruleur Lateral Pour EteindreAllumage Manuel DU Bruleur Lateral Probleme Verification SolutionDepannage Probleme Verification Maintenance DU Bruleur LateralMaintenance DU Bruleur Lateral Depannage DU Bruleur LateralMaintenance Annuelle 46MAINTENANCEProcedure DE Nettoyage DU Bruleur Principal Remplacement DES Bruleurs PrincipauxRemplacez LA Pile SI Necessaire Operations DU Systeme D’ALLUMAGE CrossoverPage Page Page Page Page Page WEBER-STEPHEN Products CO Month / MES / Mois DAY / DÍA / Jour For purchases made in the U.S