A&D HW-100KGL, HG-60KGV, HW-60KGL, HW-200KGL, HW-200KGV Step If one Has Been selected, press

Page 32

Step

6

If one of

f6 0

,

f6 2

,

f6 4

,

f6 6

has

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

been selected, press the

SET

 

switch to

 

 

use the comparator.

Step

7

Press the

 

 

 

 

switch to display the

 

MODE

 

 

HI, blinking.

Step

8

Set the upper limit value by using the

 

 

following switches.

 

 

^ switch

 

Selecting the value of a digit.

 

 

< switch

 

Selecting a digit.

 

 

F switch

 

Selecting the polarity (+,-).

Step

9

Press the

 

 

 

switch to store the new

ENTER

 

 

parameter and display the blinking LO.

Step 10

Set the lower limit value by using the

 

 

following switches.

 

 

^ switch

 

Selecting the value of a digit.

 

 

< switch

 

Selecting a digit.

 

 

F switch

 

Selecting the polarity (+,-).

Step 11

Press the

 

 

 

 

switch to store the

ENTER

 

 

new parameters and display the

 

 

weighing mode.

HW-G OZIM v1a

HW-G Instruction Manual Page 30

Image 32
Contents HW-G Series Page Contents HW-G Ozim v1a Compliance Compliance with FCC rulesOutline and Features All Accessories UnpackingAccessories and Options list Type Products AccessoriesOrder code or option name Accessories Options ListPrecautions for Storing the Scale Precautions for Installing the ScalePrecautions for Operating the Scale Installing the Scale Secure the ColumnStpe 3 Secure the Display Unit Fit the PanLevel the Scale Adjust the Display UnitConnect the Power Installing the Batteries for Type L Names Display and Symbols OFFHW-G Ozim v1a Switches HW-G Ozim v1a Memo Basic OperationTurning the Scale On/Off & Basic Weighing Type L with Batteries Tare and Net Display Semi-Automatic Tare Input by WeighingMode Switch Changing Unit & Mode Counting Mode Storing a Unit MassCounting the number of articles Percentage Mode Storing a 100% MassReading Percentage Function table Meaning & Purpose Operation and SwitchesAccumulation Function Preparation Setting Parameters Operation and Performance Examples ExampleComparator Function Comparator SignComparison Condition Function table Meaning and PurposeSwitch to display an item Step If one Has Been selected, press Case Full/Dribble Batch Function Hold ComparatorFull/Dribble batch sub-function Parameter and display an item of the full/dribble Switch to display the HI Simple Batch Function Function Table Meaning and purpose Simple batch functionPreparation Setting Parameters Mode Calibration Adjusting the Scale Gravity Acceleration Table Complete Calibration Procedure Gravity Acceleration CorrectionCalibration of the Zero Point Procedure for Setting Parameters Function Table15.2 Parameter List Display Meaning and purpose Function or full/dribble batch functionPrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Data Format FormatFormat Stream Mode Preparation and Performance ExamplesTare Command ModeCancel of tare Preset tare Upper limit valueFinal value Preparation Setting Parameters 17.1 RS-232C / Relay output / Buzzer OP-03 Pin connections Pin No Signal name Direction DescriptionOptions Pin No Signal name Direction Description 17.2 RS-422 / RS-485 / Relay output OP-04Installing OP-04 Communication Format Zero Lower limit valueReset of Accumulation data and number Accumulation data outputAccumulation count output Final valueConsumables SpecificationInternal Printer for Type V OP-06 Disassembly InstallationPerformance Check HW-G series HW-GVDimensions HW-G Ozim v1a Maintenance Check Points Before Calling MaintenanceRepair This situation Confirm these items