A&D HW-100KGL, HG-60KGV, HW-60KGL, HW-200KGL, HW-200KGV, HW-10KGV, HW100KGV, HW-10KGL Mode

Page 40

Step 6

Press the

MODE

switch to display the

 

 

HI, blinking. (Final value).

Step

7

Set the final value using the following switches.

 

 

^ switch

Selecting the value of a digit.

 

 

< switch

Selecting a digit.

Step

8

Press the

 

 

switch to store the new

ENTER

 

 

parameter and display the OK, blinking,

 

 

(Preliminary value).

Step

9

Set the preliminary value using the following

 

 

switches.

 

 

 

 

^

<

switch

Selecting the value of a digit.

switch

Selecting a digit.

Step 10 Press the ENTER switch to store the new parameter and display the LO, blinking, (Zero band).

Step 11 Set the zero band using the following switches.

^ switch

Selecting the value of a digit

< switch

Selecting a digit.

Step 12 Press the ENTER switch to store the new parameter and display the weighing mode.

13.2 Operation and Performance (Examples)

Step

1

Select the parameter f6 8 of the function table.

Step

2

Set the parameters of the final value, preliminary value and zero band.

Step

3

The comparison result is always displayed.

HW-G OZIM v1a

HW-G Instruction Manual Page 38

Image 40
Contents HW-G Series Page Contents HW-G Ozim v1a Compliance Compliance with FCC rulesOutline and Features All Accessories UnpackingAccessories and Options list Type Products AccessoriesOrder code or option name Accessories Options ListPrecautions for Operating the Scale Precautions for Installing the ScalePrecautions for Storing the Scale Installing the Scale Secure the ColumnStpe 3 Secure the Display Unit Fit the PanConnect the Power Adjust the Display UnitLevel the Scale Installing the Batteries for Type L Names Display and Symbols OFFHW-G Ozim v1a Switches HW-G Ozim v1a Turning the Scale On/Off & Basic Weighing Basic OperationMemo Type L with Batteries Tare and Net Display Semi-Automatic Tare Input by WeighingMode Switch Changing Unit & Mode Counting Mode Storing a Unit MassCounting the number of articles Percentage Mode Storing a 100% MassReading Percentage Accumulation Function Operation and SwitchesFunction table Meaning & Purpose Preparation Setting Parameters Operation and Performance Examples ExampleComparator Function Comparator SignComparison Condition Function table Meaning and PurposeSwitch to display an item Step If one Has Been selected, press Case Full/Dribble Batch Function Full/Dribble batch sub-function ComparatorHold Parameter and display an item of the full/dribble Switch to display the HI Simple Batch Function Function Table Meaning and purpose Simple batch functionPreparation Setting Parameters Mode Calibration Adjusting the Scale Gravity Acceleration Table Complete Calibration Procedure Gravity Acceleration CorrectionCalibration of the Zero Point Procedure for Setting Parameters Function Table15.2 Parameter List Display Meaning and purpose Function or full/dribble batch functionPrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Data Format FormatFormat Stream Mode Preparation and Performance ExamplesCancel of tare Command ModeTare Preset tare Upper limit valueFinal value Preparation Setting Parameters Options Pin connections Pin No Signal name Direction Description17.1 RS-232C / Relay output / Buzzer OP-03 Pin No Signal name Direction Description 17.2 RS-422 / RS-485 / Relay output OP-04Installing OP-04 Communication Format Zero Lower limit valueReset of Accumulation data and number Accumulation data outputAccumulation count output Final valueInternal Printer for Type V OP-06 SpecificationConsumables Disassembly InstallationPerformance Check HW-G series HW-GVDimensions HW-G Ozim v1a Maintenance Check Points Before Calling MaintenanceRepair This situation Confirm these items