A&D HW100KGV, HW-100KGL, HG-60KGV, HW-60KGL, HW-200KGL, HW-200KGV, HW-10KGV Zero, Lower limit value

Page 62

Zero

The current mass value is set to the zero point, this is same as the

Template Z

Command

Reply

ZERO

switch.

The mass value becomes zero and zero point mark is displayed.

Tare

The current mass value becomes zero after placing a tare (receptacle, case, etc) and the net is displayed. This is same as the TARE switch.

Template T

Command

Reply

The current mass value becomes zero and net mark is displayed.

Cancel of tare

The display value becomes the gross and the net mark is turned off. (The tare value becomes zero.)

Template CT

Command

Reply

Gross is displayed and the net mark is turned off.

Preset tare

The tare value is set and the net is displayed. The net mark is displayed.

Template PT,[parameter]

Command

Reply

Net is displayed.

Upper limit value

An upper limit value is stored.

Template HI,[parameter]

Command

Reply

The upper limit value is stored.

Lower limit value

A lower limit value is stored.

Template LO, [parameter]

Command

Reply

The lower limit value is stored.

Caution The lower limit value must be less than the upper limit value.

HW-G OZIM v1a

HW-G Instruction Manual Page 60

Image 62
Contents HW-G Series Page Contents HW-G Ozim v1a Compliance Compliance with FCC rulesOutline and Features All Accessories UnpackingAccessories and Options list Type Products AccessoriesOrder code or option name Accessories Options ListPrecautions for Storing the Scale Precautions for Installing the ScalePrecautions for Operating the Scale Stpe 3 Secure the Display Unit Installing the ScaleSecure the Column Fit the PanLevel the Scale Adjust the Display UnitConnect the Power Installing the Batteries for Type L Names Display and Symbols OFFHW-G Ozim v1a Switches HW-G Ozim v1a Memo Basic OperationTurning the Scale On/Off & Basic Weighing Type L with Batteries Tare and Net Display Semi-Automatic Tare Input by WeighingMode Switch Changing Unit & Mode Counting Mode Storing a Unit MassCounting the number of articles Percentage Mode Storing a 100% MassReading Percentage Function table Meaning & Purpose Operation and SwitchesAccumulation Function Preparation Setting Parameters Operation and Performance Examples ExampleComparison Condition Comparator FunctionComparator Sign Function table Meaning and PurposeSwitch to display an item Step If one Has Been selected, press Case Full/Dribble Batch Function Hold ComparatorFull/Dribble batch sub-function Parameter and display an item of the full/dribble Switch to display the HI Simple Batch Function Function Table Meaning and purpose Simple batch functionPreparation Setting Parameters Mode Calibration Adjusting the Scale Gravity Acceleration Table Complete Calibration Procedure Gravity Acceleration CorrectionCalibration of the Zero Point Procedure for Setting Parameters Function Table15.2 Parameter List Display Meaning and purpose Function or full/dribble batch functionPrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Data Format FormatFormat Stream Mode Preparation and Performance ExamplesTare Command ModeCancel of tare Preset tare Upper limit valueFinal value Preparation Setting Parameters 17.1 RS-232C / Relay output / Buzzer OP-03 Pin connections Pin No Signal name Direction DescriptionOptions Pin No Signal name Direction Description 17.2 RS-422 / RS-485 / Relay output OP-04Installing OP-04 Communication Format Zero Lower limit valueAccumulation count output Reset of Accumulation data and numberAccumulation data output Final valueConsumables SpecificationInternal Printer for Type V OP-06 Disassembly InstallationPerformance Check HW-G series HW-GVDimensions HW-G Ozim v1a Repair MaintenanceCheck Points Before Calling Maintenance This situation Confirm these items