A&D HW-200KGL, HW-100KGL, HG-60KGV, HW-60KGL, HW-200KGV, HW-10KGV, HW100KGV HW-G series, Hw-Gv

Page 67

HW-G series

Product

HW-10KGL

 

HW-60KGL

HW-100KGV

 

HW-200KGV

 

HW-10KGV

 

HW-60KGV

HW-100KGL

 

HW-200KGL

 

 

 

 

 

 

 

Weighing Capacity [kg]

10

 

60

100

220

Min. weighing (1 digit) [g]

1

 

5

10

20

Number of samples in

 

 

 

 

 

 

counting mode [units]

5 can be changed to 10 20 50 100

 

 

Max. count number [units]

10,000

 

12,000

10,000

 

11,000

Display HW-GL

7 segment liquid crystal display, Character height 25mm

HW-GV

7 segment fluorescent display, Character height 20mm

Repeatability [g]

±2

 

±10

±20

 

±40

Linearity [g]

±2

 

±10

±20

 

±40

Span drift

20ppm/°C typ. (5°C ~ 35°C)

 

 

Power source HW-GL

AC adaptor

Please confirm that the AC adaptor type

 

 

 

is correct for your local voltage and receptacle.

 

Battery x 6 pieces type ‘D’

 

 

 

HW-GV

Please confirm that the Main power type is correct for your

 

local voltage and receptacle type.

 

 

 

 

Battery life (HW-GL)

Approximately 600 hours with alkaline dry cell battery

 

 

 

 

 

 

 

Ambient temperature

 

 

 

 

 

 

and humidity

-10°C ~ 40°C, Less than 85%R.H. (Non- condensing)

 

 

 

 

 

 

Weighing pan size [mm]

250 x 250

 

330 x 424

390 x 530

 

390 x 530

 

 

 

 

 

 

 

Dimension [mm]

 

 

 

 

 

 

Width x Depth x Height

275 x 474 x 368

 

330 x 621 x 771

390 x 712 x 773

 

390 x 712 x 773

Mass of scale [kg] HW-GL

6

 

11

17

17

HW-GV

7

 

12

18

18

 

 

 

 

 

 

 

HW-G Instruction Manual Page 65

HW-G OZIM v1a

Image 67
Contents HW-G Series Page Contents HW-G Ozim v1a Compliance with FCC rules ComplianceOutline and Features Unpacking All AccessoriesType Products Accessories Accessories and Options listOptions List Order code or option name AccessoriesPrecautions for Operating the Scale Precautions for Installing the ScalePrecautions for Storing the Scale Fit the Pan Installing the ScaleSecure the Column Stpe 3 Secure the Display UnitConnect the Power Adjust the Display UnitLevel the Scale Installing the Batteries for Type L Names OFF Display and SymbolsHW-G Ozim v1a Switches HW-G Ozim v1a Turning the Scale On/Off & Basic Weighing Basic OperationMemo Type L with Batteries Semi-Automatic Tare Input by Weighing Tare and Net DisplayMode Switch Changing Unit & Mode Storing a Unit Mass Counting ModeCounting the number of articles Storing a 100% Mass Percentage ModeReading Percentage Accumulation Function Operation and SwitchesFunction table Meaning & Purpose Preparation Setting Parameters Example Operation and Performance ExamplesFunction table Meaning and Purpose Comparator FunctionComparator Sign Comparison ConditionSwitch to display an item Step If one Has Been selected, press Case Full/Dribble Batch Function Full/Dribble batch sub-function ComparatorHold Parameter and display an item of the full/dribble Switch to display the HI Function Table Meaning and purpose Simple batch function Simple Batch FunctionPreparation Setting Parameters Mode Calibration Adjusting the Scale Gravity Acceleration Table Gravity Acceleration Correction Complete Calibration ProcedureCalibration of the Zero Point Function Table Procedure for Setting Parameters15.2 Parameter List Function or full/dribble batch function Display Meaning and purposePrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Format Data FormatFormat Preparation and Performance Examples Stream ModeCancel of tare Command ModeTare Upper limit value Preset tareFinal value Preparation Setting Parameters Options Pin connections Pin No Signal name Direction Description17.1 RS-232C / Relay output / Buzzer OP-03 17.2 RS-422 / RS-485 / Relay output OP-04 Pin No Signal name Direction DescriptionInstalling OP-04 Communication Format Lower limit value ZeroFinal value Reset of Accumulation data and numberAccumulation data output Accumulation count outputInternal Printer for Type V OP-06 SpecificationConsumables Installation DisassemblyPerformance Check HW-GV HW-G seriesDimensions HW-G Ozim v1a This situation Confirm these items MaintenanceCheck Points Before Calling Maintenance Repair