Caution

The comparison of the full/dribble batch function is not reversible (One way se- quence). If the display value becomes less than the final value after the value reached a predetermined target value, neither HI or LO is on.

The parameters of the upper limit value (HI) and the final value (HI) use the same memory. The parameters of the lower limit value (LO) and the zero band (LO) use the same memory.

The upper/lower comparator function, the simple batch function and the full/dribble batch function cannot be used at the same time because these parameters use common memory.

Set the zero band greater than the tare value.

Operation

Pressing the SET switch, the scale starts the batch process.

Selecting a parameter from f10 0 or f10 2 of the full/dribble batch sub-function, the F switch works as the finish switch.

Parameter List and Word Definition

The “gross” is a total weighing value, no tare value is subtracted.

The “net” is a measurement value with the tare value subtracted from the gross. The “zero band” means the zero detection level.

The “zero point” is the fundamental starting point to weighing.

Comparator

Function tableMeaning and purpose

f6 9 Full/Dribble batch function

Full/Dribble batch sub-function

 

Function table

 

Meaning and purpose

 

 

f10

0

 

Reaching final value and pressing the F switch the current process is

 

 

 

 

 

finished.

 

 

 

f10

1

 

Reaching the final value and displaying the stability mark the current

 

 

 

 

 

process is finished automatically.

 

 

 

f10

2

 

Pressing the

 

 

 

switch the scale automatically tares and starts the

 

 

 

SET

 

 

 

 

 

full/dribble batch process. Reaching final value anf pressing the F switch,

 

 

 

 

 

the current process is finished.

 

 

f10

3

 

Pressing the

 

switch the scale automtically tares and starts the

 

 

 

 

SET

 

 

 

 

 

 

full/dribble batch process. Reaching the final value and displaying the

 

 

 

 

 

stability mark the current process is finished.

Hold

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Function table

 

Meaning and purpose

 

 

f12

0

 

The hold function is not used

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HW-G Instruction Manual Page 33

HW-G OZIM v1a

Image 35
Contents HW-G Series Page Contents HW-G Ozim v1a Compliance with FCC rules ComplianceOutline and Features Unpacking All AccessoriesType Products Accessories Accessories and Options listOptions List Order code or option name AccessoriesPrecautions for Storing the Scale Precautions for Installing the ScalePrecautions for Operating the Scale Fit the Pan Installing the ScaleSecure the Column Stpe 3 Secure the Display UnitLevel the Scale Adjust the Display UnitConnect the Power Installing the Batteries for Type L Names OFF Display and SymbolsHW-G Ozim v1a Switches HW-G Ozim v1a Memo Basic OperationTurning the Scale On/Off & Basic Weighing Type L with Batteries Semi-Automatic Tare Input by Weighing Tare and Net DisplayMode Switch Changing Unit & Mode Storing a Unit Mass Counting ModeCounting the number of articles Storing a 100% Mass Percentage ModeReading Percentage Function table Meaning & Purpose Operation and SwitchesAccumulation Function Preparation Setting Parameters Example Operation and Performance ExamplesFunction table Meaning and Purpose Comparator FunctionComparator Sign Comparison ConditionSwitch to display an item Step If one Has Been selected, press Case Full/Dribble Batch Function Hold ComparatorFull/Dribble batch sub-function Parameter and display an item of the full/dribble Switch to display the HI Function Table Meaning and purpose Simple batch function Simple Batch FunctionPreparation Setting Parameters Mode Calibration Adjusting the Scale Gravity Acceleration Table Gravity Acceleration Correction Complete Calibration ProcedureCalibration of the Zero Point Function Table Procedure for Setting Parameters15.2 Parameter List Function or full/dribble batch function Display Meaning and purposePrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Format Data FormatFormat Preparation and Performance Examples Stream ModeTare Command ModeCancel of tare Upper limit value Preset tareFinal value Preparation Setting Parameters 17.1 RS-232C / Relay output / Buzzer OP-03 Pin connections Pin No Signal name Direction DescriptionOptions 17.2 RS-422 / RS-485 / Relay output OP-04 Pin No Signal name Direction DescriptionInstalling OP-04 Communication Format Lower limit value ZeroFinal value Reset of Accumulation data and numberAccumulation data output Accumulation count outputConsumables SpecificationInternal Printer for Type V OP-06 Installation DisassemblyPerformance Check HW-GV HW-G seriesDimensions HW-G Ozim v1a This situation Confirm these items MaintenanceCheck Points Before Calling Maintenance Repair