Local Administrative Options
2.Enter a valid value between 0 and 7 for the new value of the 802.1 audio parameter. The following text displays
L2 signaling=d
New=_
where d is the value of the 802.1 signaling parameter.
3.Enter a valid value between 0 and 7 for the new value of the 802.1 signaling parameter. The following text displays
L3 audio=dd
New=_
where dd is the value of the Differential Services audio parameter.
4.Enter a valid value between 0 and 63 for the new value of the Differential Services audio parameter.
The following text displays
L3 signaling=dd
New=_
where dd is the value of the Differential Services signaling parameter.
5.Enter a valid value between 0 and 63 for the new value of the Differential Services signaling parameter.
If no new values were entered during this procedure, the following text displays
No new values. #=OK
6.Press # to terminate the procedure.
If new values were entered during this procedure, the following text displays
Save new values?
*=no #=yes
7.Press the * button to terminate the procedure, or the # button to save the new values. If you press the # button, the following text displays:
New values being saved
The new values are saved, and the user interface is restored to its previous state.