3 Setting Up Your System | Quick Reference Guide | |
|
|
|
|
|
|
Automatic Daylight/Standard Times (#126)
Available in Release 3.0 or later systems, this feature is turned on by default and automatically updates the system clock for annual Daylight Savings Time and Standard Time changes. If you are in an area that does not have daylight savings time, use the procedure below to turn off this feature.
To change the status of Automatic Daylight/Standard Time:
1Press f00ss#126at extension 10 or 11.
2Press Duntil the appropriate value appears:
•1 = Active (the factory setting) ✔
•2 = Not Active
3Select another procedure, or exit programming mode.
Assigning Lines
Use the feature Number of Lines (#104) to determine in Key mode the number of outside lines that are automatically assigned to all system extensions, or to determine in Hybrid mode the number of lines assigned to the main pool. After you use the Number of Lines feature, you can use other features to refine the assignment of lines.
Line assignment is also based upon whether an extension is a Key or Pooled extension. Refine the line assignment accordingly after you use the Number of Lines feature.
CAUTION:
Do not use Number of Lines (#104) after initial setup.
Refer to the PARTNER Advanced Communications System Installation, Programming, and Use guide for more detail.
28 Assigning Lines