Avaya 700217243 manual Wall-Mounting a 5-Slot Carrier and Modules

Page 20

2 Installing Your System

Quick Reference Guide

 

 

 

 

 

 

Wall-Mounting a 5-Slot Carrier and Modules

Install the 5-slot carrier within 5 feet (1.5 meters) of a properly grounded wall outlet (not controlled by a switch) and the network interface jacks. When you mount the carrier on the wall, leave at least 1 foot (0.3 meter) of clearance at the top and sides and 2 feet (0.6 meter) at the front and bottom to ensure proper ventilation.

The location of each module within the carrier is important; place the modules as instructed in the following procedure.

Follow these steps to wall-mount the 5-slot carrier and modules:

1Using the enclosed template, mark the screw locations on the wall. If you are mounting the carrier on plywood, start four #12 screws supplied with the carrier, leaving the screw heads extending approximately 1/4 inch (0.64 cm) from the wall. If you are mounting on drywall, use wall anchors, which must be purchased separately.

2Before installing any modules, make sure the clear, plastic protector has been removed from the connector area on the rear of each module. To remove the protector, grasp the tabs on the ends of the protector and lift.

3Insert the PARTNER ACS processor module in the center slot of the carrier.

4In the other slots, from left to right, first install the 1600 DSL module (if used), then the 012E, 308EC, or 206 modules, followed by the 400 or 200 modules and/or a PARTNER Messaging or PARTNER MAIL VS module. Align the module carefully in the appropriate slot. For proper engagement of the connectors, the module must be inserted straight into the carrier. Once the module is properly seated, firmly push the center of the module until the connectors on the module lock into place. A slight click indicates the connectors are engaged.

10 Installing the Control Unit

Image 20
Contents Partner Page Copyright Document Avaya Inc Obtaining Products Important Safety Instructions Page Wed like your opinion Page Contents Programming Telephone Features System Programming Flow ChartsMaintaining Your System If Something Doesn’t WorkWelcome System OverviewSystem Configurations System Capacity System ComponentsSystem Description Components Auxiliary Equipment OpreGetting Acquainted Installing Your System OverviewInstalling the Control Unit Evaluating the EnvironmentGo to the next procedure, Labeling Jacks, on Wall-Mounting a 5-Slot Carrier and Modules Labeling Jacks Grounding the System Inserting Batteries in the Processor ModuleQuick Reference Guide Initializing the System Checking the LEDs Connecting Lines and Extensions Installing the Cover Installing TelephonesConnecting Auxiliary Equipment Setting Up Your System System Programming BasicsSetting Up Your System Programming Overlays Button Locations Button Locations on Partner Telephones Programming Mode Changing Programming TypeUsing Centralized Telephone Programming System Day #102, Release 2.0 and Earlier Setting the Date, Day, and TimeSystem Date #101 System Time #103 Assigning Lines Automatic Daylight/Standard Times #126Customizing Extensions Copy Settings #399 Dialing Restrictions Changing Settings to Support PBX or Centrex ServicesRecall Setting Emergency Phone Number List #406 Speed Dial and Auto Dial NumbersVoice Messaging Systems Programming for Voice Messaging SystemsSetting Up Your System Additional Voice Messaging System Programming Setting Up Your System Programming System Features System Speed DialDialing Restrictions and Permissions 5554757Allowed Phone Number Lists #407 Security AlertAllowed List Assignments #408 Disallowed Phone Number Lists #404 Line Access Restriction #302 Disallowed List Assignments #405Current restriction appears Outgoing Call Restriction #401 Groups of Extensions Group...DescriptionProgramming System Features Programming Telephone Features Automatic Line SelectionProgramming Telephone Features Extension Name Display Letters NumbersLine Ringing Quick Reference Guide Programming Telephone Features Maintaining Your System Backup and Restore Backup Programming-Automatic #123 Backup Programming-Manual #124 Restore Programming #125 Maintaining Your System Battery Replacement Using a PC Card Quick Reference Guide Upgrading 1600 DSL and 012E Module Firmware Check the LEDsAdding New Modules Maintaining Your System Replacing Modules Maintaining Your System Replacing Modules in a 5-Slot Carrier Maintaining Your System Changing the System Clock Changing System SettingsAdding Lines, Pools, and Extensions Adding New Lines Key ExtensionsAdding New Pools Adding New ExtensionsSwapping Extensions If Something Doesn’t Work Your Release NumberClearing a Backup-Failure Alarm Press f00ss#123012E Module Power Management Telephone Problems Problem Check thisProblem Check this Calling Problems Telephone Doesn’t Work onProblem Check this System Problems DSL Module Problems ATMTip/Ring Device Problems System Programming Flow Chart-How to Use System Flow Chart-System System Flow Chart-System Speed Dial Numbers System Flow Chart-LinesSystem Flow Chart-Extensions Line Access Mode Copy SettingsCall Waiting Pool Extension AssignmentSystem Flow Chart-Dialing Restrictions and Permissions System Flow Chart-Groups System Flow Chart-Auxiliary Equipment Centralized Telephone Programming Flow Chart-How to Use To Program Another Feature at the Same ExtensionTo Change Setting for Another Extension To Erase a Feature or Auto Dial ButtonCentralized Telephone Programming Flow Chart For voice signaling the first available extension Manual SignalingTouch-Tone Enable Contact ClosureExtension Telephone Programming Flow Chart-How to Use Extension Telephone Programming Flow Chart Caller ID InspectRecord-A-Call Group Hunting-Ring/Voice SignalLoudspeaker Paging