Avaya 700217243 manual System Flow Chart-System

Page 94

System Flow Chart–System

Automatic System Answer Mode

System Date

Dial #101

Dial the date (MMDDYY)

System Day

 

Dial #102

2.0 or earlier

 

Dial 1=Sun ✔

 

2=Mon 3-Tue, 4=Wed, 5=Thur, 6=Fri, 7=Sat

System Time

Dial #103

Dial the time (HHMM-24 hr. military time)

Transfer Return Rings

Dial #105

Dial 1 digit (0–9) for # of rings before call returns.

0–9 rings

4 rings ✔

0 rings=no return

Recall Timer Durations

Dial #107

Dial two digits (01–80) to set length of a switchook flash ✔=18 (450 msec)

Direct Extension Dial Button

Dial #113

2.0

Dial 1=Assigned 2=Not Assigned ✔

3=Select Button then press a programmable button

Outgoing Call

Restriction Button

Dial #114 Dial 1=Assigned

2=Not Assigned ✔

3=Select Button then press a programmable button

Dial #121 Dial 1=Hold ✔

2=Disconnect

3=Ring

Caller ID Type

Dial #122 Dial 1=USA ✔

2=Singapore

Backup Programming Automatic

Dial #123 Dial 1=Active

2=Not Active ✔ 3=Backup Alarm Cleared

Number of Lines

Dial #104

Dial two digits (01–31) (R. 4.0) or, Dial two digits (01–19 (Prior R. 4.0), for # of outside lines assigned to every extension. 3 per ACS processor & 308EC module. 16 for 1600DSL module. 2 per 206 or 200 module ✔. 4 per 400EC module ✔.

WARNING

Do not use Number of Lines (#104) after initial setup. In Key mode, the Number of lines procedure will change Line Assignment (#301), Line Access Restriction (#302), Automatic Line Selection and Line Ringing to factory settings.

To change line assignments without affecting other settings, use Line Assignment (#301).

In Hybrid mode, the Number of Lines procedure will change Pool Line Assignment (#207), Pool Extension Assignment (#314), and Pool Access Restriction (#315). Additionally, it changes Line Assignment (#301), Line

Rotary Dialing Timeout

Dial #108 Dial 1=4 secs

2=8 secs ✔ 3=12 secs

Outside Conference Denial

Dial #109 Dial 1=Allowed ✔ 2=Disallowed

Automatic System Answer Delay

Dial #110 2.0 Dial a ring delay number (0–9)

2 rings ✔

Automatic System Answer Button

Dial #111

2.0

Dial 1=Assigned,

 

2=Not Assigned ✔

3=Select Button then press a programmable button

Wake Up Service Button

Dial #115

Dial 1=Assigned 2=Not Assigned ✔ 3=Select Button then press a programmable button

Call Coverage Rings

Dial #116 2.0 Dial 1–9

2

VMS Cover Rings

Dial #117

Dial 1–9

3

Ring On Transfer

Dial #119 Dial 1=Active ✔ 2=Not Active

Backup Programming—Manual

Dial #124

Press eto begin the backup

Restore Programming

Dial #125

Dial 1=MAN.mmddyy ✔ 2=AUTO.mmddyy

Press eto begin the restore

Automatic Daylight/

 

 

3.0

 

Standard Times Dial #126 Dial 1=Active ✔ 2=Not Active

Mode of Operation

Press f00s s#198

Enter the system password Dial 1=Key (factory setting) ✔

2=Hybrid

Access Restriction (#302), Automatic Line Selection and Line Ringing. To change pool assignments without affecting other settings, use Pool Line Assignment (#207) and Pool Extension Assignment (#314).

Direct Extension Dial Delay

2.0

Dial #112

 

Dial a ring delay number (0–9) 2 rings ✔,

0 rings=answered immediately

System Reset—Programming Saved

IMPORTANT: Using this procedure disconnects any active calls but retains system settings. Use it only if the system fails to function correctly after a power failure or down period. Dial #728.

Image 94
Contents Partner Page Copyright Document Avaya Inc Obtaining Products Important Safety Instructions Page Wed like your opinion Page Contents Maintaining Your System Programming Telephone FeaturesSystem Programming Flow Charts If Something Doesn’t WorkWelcome System OverviewSystem Configurations System Capacity System ComponentsSystem Description Components Auxiliary Equipment OpreGetting Acquainted Installing Your System OverviewInstalling the Control Unit Evaluating the EnvironmentGo to the next procedure, Labeling Jacks, on Wall-Mounting a 5-Slot Carrier and Modules Labeling Jacks Grounding the System Inserting Batteries in the Processor ModuleQuick Reference Guide Initializing the System Checking the LEDs Connecting Lines and Extensions Installing the Cover Installing TelephonesConnecting Auxiliary Equipment Setting Up Your System System Programming BasicsSetting Up Your System Programming Overlays Button Locations Button Locations on Partner Telephones Programming Mode Changing Programming TypeUsing Centralized Telephone Programming System Date #101 Setting the Date, Day, and TimeSystem Day #102, Release 2.0 and Earlier System Time #103 Assigning Lines Automatic Daylight/Standard Times #126Customizing Extensions Copy Settings #399 Recall Setting Changing Settings to Support PBX or Centrex ServicesDialing Restrictions Emergency Phone Number List #406 Speed Dial and Auto Dial NumbersVoice Messaging Systems Programming for Voice Messaging SystemsSetting Up Your System Additional Voice Messaging System Programming Setting Up Your System Programming System Features System Speed DialDialing Restrictions and Permissions 5554757Allowed Phone Number Lists #407 Security AlertAllowed List Assignments #408 Disallowed Phone Number Lists #404 Line Access Restriction #302 Disallowed List Assignments #405Current restriction appears Outgoing Call Restriction #401 Groups of Extensions Group...DescriptionProgramming System Features Programming Telephone Features Automatic Line SelectionProgramming Telephone Features Extension Name Display Letters NumbersLine Ringing Quick Reference Guide Programming Telephone Features Maintaining Your System Backup and Restore Backup Programming-Automatic #123 Backup Programming-Manual #124 Restore Programming #125 Maintaining Your System Battery Replacement Using a PC Card Quick Reference Guide Upgrading 1600 DSL and 012E Module Firmware Check the LEDsAdding New Modules Maintaining Your System Replacing Modules Maintaining Your System Replacing Modules in a 5-Slot Carrier Maintaining Your System Adding Lines, Pools, and Extensions Changing System SettingsChanging the System Clock Adding New Lines Key ExtensionsAdding New Pools Adding New ExtensionsSwapping Extensions If Something Doesn’t Work Your Release NumberClearing a Backup-Failure Alarm Press f00ss#123012E Module Power Management Telephone Problems Problem Check thisProblem Check this Calling Problems Telephone Doesn’t Work onProblem Check this System Problems DSL Module Problems ATMTip/Ring Device Problems System Programming Flow Chart-How to Use System Flow Chart-System System Flow Chart-System Speed Dial Numbers System Flow Chart-LinesSystem Flow Chart-Extensions Call Waiting Line Access ModeCopy Settings Pool Extension AssignmentSystem Flow Chart-Dialing Restrictions and Permissions System Flow Chart-Groups System Flow Chart-Auxiliary Equipment To Change Setting for Another Extension Centralized Telephone Programming Flow Chart-How to UseTo Program Another Feature at the Same Extension To Erase a Feature or Auto Dial ButtonCentralized Telephone Programming Flow Chart Touch-Tone Enable For voice signaling the first available extensionManual Signaling Contact ClosureExtension Telephone Programming Flow Chart-How to Use Extension Telephone Programming Flow Chart Caller ID InspectLoudspeaker Paging Group Hunting-Ring/Voice SignalRecord-A-Call