BT 106 manual Technical information, Dtmf

Page 37

Ultimate 106 – Edition 2 – Issue 3 - 24.12.02 – 5129

Technical information

RTTE

Hereby Promotion & Display Technology Ltd. declares that this

 

Ultimate 106 is in compliance with the essential requirements and other

 

relevant provisions of Directive 1999/5/EC.

 

The Declaration of Conformance for the Ultimate 106 is published on the

 

Website: http.//www.pdtuk.com/archive/certificates/ultimate/default.htm

 

 

Installation information

The Ultimate 106 connects to one exchange line and six (2 wire)

 

telephone extensions.

 

 

Signalling

DTMF.

 

Pulse dialling (typical 10 pps).

 

RECALL to external line – duration: 100ms.

 

type: timed break.

 

RECALL detection from extension – duration: 85ms to 200ms,

 

type: timed break.

 

 

REN

REN of the Ultimate 106 is 4.

 

Maximum REN per extension is 2.

 

 

Environmental conditions

Temperature range: (storage) –10C to 60C, (operating) 0C to 55C.

 

Humidity range: (storage) 65%, (operating) 60% maximum.

 

 

Ring cadences

Internal: 1s ON, 2s OFF.

 

External: 0.4s ON, 0.2s OFF, 0.4s ON, 2s OFF.

 

Door-phone: 0.5s ON, 2.5s OFF.

 

Alarm call: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.

 

Internal Ring-back: 0.2s ON, 0.2s OFF, 0.2s ON, 0.2s OFF, 0.2s ON, 2s OFF.

 

External Ring-back: 0.5s ON, 0.3s OFF, 0.2s ON, 2s OFF.

 

 

Power Supply (internal)

Power supply 220-240V AC 50/60Hz.

 

Power consumption 45W.

 

 

Weight

Weight 1.5kg.

 

 

Dimensions (approx.)

Height: 200mm. Width: 295mm. Depth: 48mm (52mm from wall).

 

 

37

Image 37
Contents Ultimate User GuidePersonal Emergency Numbers For your recordsContents Unpacking your Ultimate IntroductionWall mounting the Ultimate Extension numbers InstallationTo connect up to 6 master extension sockets Install the required number Extension socketsRemove the lower cover from the Ultimate Connect the extension sockets to the UltimateConnect the telephone line cord Connect the power cableTo make any system settings System settingsTime is 3.15pm Time and date settingsMonday February 27th To set the timeRing delay is 3 rings and day mode Extension ring delay Day and night modesTo set the ring delay To stop extensions from ringing during the day To select which extensions ring during the dayTo select which extensions ring during the night Night mode start 6pm Day mode start 830 a.mCreating a hotline number Call barringExample Extension 12 barring is level Example Extension 12 is set for hotlineExtension 12 is set for payphone Connecting a payphoneExtension 12 is set for normal Resetting the system Connecting a fax machineCall Sign on, delay off Call Sign on, delay onPlaying music to callers on hold Announce System resetAnswering Machine To select answering machine modeCall Director To set-up Answering MachineAnswering delay is two rings Announces Answering delay is setAnswering delay is six rings Answering delay is nine ringsAnnounces Call Director is set To set up Call DirectorAnnounces Call Director is on Announces Call Director is offTo record a Call Director OGM Record your call director message after the toneTo replay the Call Director OGM Call Director, example OGMsYour messages Playing back your messagesPush square to confirm To program your PIN To hear how much recording time is remainingTo operate your Answering Machine from another telephone Making and receiving calls Using your phone extensionsTo hold a 3-way call To put a call on holdTo transfer a call between extensions To forward calls to another extensionAlarm cleared Alarm on amAnnounces Extension divert is off Announces Extension do not disturb is setUsing Ringback Using your Ultimate 106 as a Room MonitorRingback Extension X or Ringback To set the Room MonitorEnter 2 digit location and number Using the speed dial memoryIntercom Ring a telephone number To dial a speed dial number To store the last dialled call as a speed dial numberUsing Caller Identification Using BT Select ServicesTo set the Caller Identification options at each extension To screen incoming calls using Caller IdentificationTo review calling numbers To use BT’s Call Waiting service BT’s Call Waiting serviceTo switch between 2 callers Service MaintenanceTo wall mount the Ultimate 106 base unit Wall mountingHelp Are you in the correct programming mode i.e. program/normalDtmf Technical informationNormal mode Ultimate 106 default settingsGlobal programming mode Index OGM Offices worldwide