ELECTRICAL

DOUBLE INSULATION

Double insulation is a concept in safety in electric products, which eliminates the need for the usual three-wire grounded power cord. All exposed metal parts are isolated from the internal metal motor components with protecting insulation. Double insulated products do not need to be grounded.

WARNING:

The double insulated system is intended­ to protect the user from shock resulting from a break in the product’s internal wiring. Observe all normal safety precautions to avoid electrical shock.

NOTE: Servicing of a product with double insulation requires extreme care and knowledge of the system and should be performed only by a qualified service technician. For service, we suggest you return the product to your nearest authorized service center for repair. Always use original factory replacement parts when servicing.

ELECTRICAL CONNECTION

This product should be connected to a power supply that is 120 volts, AC only (normal household current), 60 Hz.

Do not operate this product on direct current (DC) through the power cord. A substantial voltage drop will cause a loss of power and the motor will overheat. If the product does not operate when plugged into an outlet, double-check the power supply.

EXTENSION CORDS

When using a product at a considerable distance from a power source, be sure to use an extension cord that has the capacity to handle the current the product will draw. An undersized cord will cause a drop in line voltage, resulting in overheating and loss of power. Use the chart to determine the minimum wire size required in an extension cord. Only round jacketed cords listed by Underwriter’s Laboratories (UL) should be used.

Before using any extension cord, inspect it for loose or exposed wires and cut or worn insulation.

**Ampere rating (on product data plate)

0-2.0 2.1-3.4 3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0

Cord Length

 

Wire Size (A.W.G.)

 

 

 

 

 

 

 

 

 

25'

16

16

16

16

14

14

 

 

 

 

 

 

 

50'

16

16

16

14

14

12

100'

16

16

14

12

10

 

 

 

 

 

 

 

**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge

WARNING:

Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with this product. Failure to do so can result in serious personal injury.

WARNING:

Check extension cords before each use. If damaged replace immediately. Never use a product with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury.

7 - English

Image 7
Contents Save this Manual for Future Reference OPERATOR’S ManualIntroduction WarrantyProduct USE and Care General Safety RulesElectrical Safety Personal SafetyService Specific Safety RulesSafety Rules for Charger Important Safety InstructionsCalifornia Proposition SymbolsOther reproductive harm. Wash hands after handling Electrical Connection Cord Length Wire Size A.W.GElectrical Double InsulationFeatures Packing List AssemblyFCC Compliance UnpackingOperation Battery Protection FeaturesTo Install / Remove AAA Batteries Included To INSTALL/REMOVE Battery Pack not IncludedStoring a Preset in Memory Adjusting the VolumeMode Selection Manual TuningUsing MP3 and CD Players Setting the ClockCharging Charging a Cold Battery Pack Charging a HOT Battery PackReplacing the Antenna MaintenanceGeneral Maintenance Battery Pack Removal and Preparation for RecyclingTable DES Matières Règles DE Sécurité Générales Dépannage Règles DE Sécurité ParticulièresAvertissement Règles DE Sécurité Pour LE ChargeurProposition 65 DE LA Californie Avertissement SymbolesAVERTISSEMENT  NOM Désignation / ExplicationCordons Prolongateurs Caractéristiques ÉlectriquesDouble Isolation Connexions ÉlectriquesCaractéristiques Déballage AssemblageListe DE Contrôle D’EXPÉDITION Caractéristiques DE Protection DES Piles Installation ET Remplacement DES DES Piles DE AAA ComprisesRETRAIT/INSTALLATION DUE BLOC-PILES NON Fourni UtilisationACL Rétroéclairé Réglage DU VolumeSélection DU Mode Conseils Généraux D’UTILISATIONPour visualiser l’heure Réglage DE L’HORLOGEPour syntoniser les stations préréglées FM ou AM Réglage de l’heureSignaux DES Témoins DEL Charge D’UN Bloc DE Piles Froid Remplacement DE L’ANTENNEEntretien Charge D’UN Bloc DE Piles Chaud10-14 Índice DE ContenidoIntroducción GarantíaSeguridad Personal Reglas DE Seguridad Generales¡ADVERTENCIA Seguridad EléctricaReglas DE Seguridad Específicas Instrucciones DE Seguridad GeneralesServicio LEA Y Comprenda Todas LAS INSTRUCCIONES. El Reglas DE Seguridad Para EL Empleo DEL CargadorPrecaución SímbolosPeligro AdvertenciaCordones DE Extensión Aspectos EléctricosDoble Aislamiento Conexión EléctricaCaracterísticas Lista DE Empaquetado ArmadoCumplimiento DE LAS Normas DE LA FCC DesempaquetadoPara Instalar Y Quitar Baterías AAA Incluida FuncionamientoUsos Características DE Protección DE LAS BateríasPantalla DE Cristal Líquido Ajuste DEL VolumenCORDÓN, Sólo CORR. ALT Consejos DE USO GeneralUSO DE Reproductores DE MP3 Y Reproductores DE CD Tajuste DEL RelojCarga Funcionamiento DE LOS Diodos Luminiscentes Mantenimiento General MantenimientoCómo Cargar LA Batería Cuando Está Caliente Cómo Cargar LA Batería Cuando Está FríaCâble NON COMPRIS, Cable no Incluido Cable not IncludedTUNE/SEEK/DOWN syntonisation/chercher/bas, recorrer/abajo Charger LED Status P745 P745