Installing the XC Series

5.Install the cable strain relief on the XC Series end of the source AC cable.

6.Carefully remove 50 – 75 mm (2 – 3 in.) of the outer jacket, being careful not to cut or nick the insulation on the individual conductors.

7.Pull the XC Series pigtail wires out through the access hole.

8.Thread the source AC cable through the knockout beneath the wiring compartment cover and then pull it out through the access hole.

9.Connect the AC wiring to the XC Series pigtail wires, being sure to connect the line conductor to the line, the neutral to the neutral, and the ground to the ground. The pigtail wires are color coded as follows:

Conductor

Color code

 

 

Line

Black or brown

Neutral

White or blue

Ground

Green with yellow stripe

10.Make the connections with twist-on or crimp-on connectors or with other approved connectors suitable for your installation. For example, the ABYC Standards and Recommended Practices for Small Craft prohibit twist-on connectors for AC connections on a boat. For non-marine installations in locations not subject to vibration, either type of connector may be used. For marine installations, follow the procedure for installing butt splice connectors.

975-0187-01-01

2–5

Image 31
Contents Owner’s Guide Battery ChargerPage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Organization PurposeScope AudienceRelated Information Conventions UsedImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Specifications TroubleshootingOperation Introduction XC Series provides the following protection features XC Series provides the following standard featuresXC Series XC Series AppearanceRemote Display Information Centers of the XC SeriesInformation Centers of the XC Series Onboard Status Panel CHfDescription Rear Panel5XC Series System Preparing for InstallationYou need the following materials Tools and MaterialsCondition Requirement Location6XC Series Mounting Orientations DC Wiring Wiring RequirementsOver-current protection disconnect AC WiringBattery Bank Size Requirements Installation Installation Sequence Installing the XC SeriesTo install DC wiring Pre-Installing DC WiringTo install AC wiring Pre-Installing AC WiringConductor Color code To connect AC wires with the crimp-on butt-splice connector To remove the display Mounting the Remote DisplayTo secure the display or blank plate on the unit To remotely mount the display MountingTo mount the XC Series Grounding Shows the connection order Final ConnectionsTo make the last DC connections Final DC ConnectionsTo make the last AC connections Powering UpBattery Temperature Sensor Installing Optional AccessoriesTo install a BTS To install rubber boots Drip Protection Rubber BootsTo configure the battery bank type Configuring the XC SeriesTo configure the charging type Operation Multiplex 3-Stage Charging About ChargingSequential 2-Stage Charging To force a battery detection sequenceCharging Overview Disqualified Batteries Temperature ConsiderationsPerform these disqualification checks in the order shown Things to be awareTo charge your batteries Charging BatteriesCharging Batteries About Equalizing Equalizing Flooded BatteriesTo equalize your batteries Performing An EqualizationThere is only one way to safely turn the XC Series off Transitioning the XC Series to On, Disabled or OffThere are two ways to disable the XC Series There are two ways to turn the XC Series onReading Remote Display and Onboard Status Indicator Lights Accessing Charger InformationABS Reporting While Charging or Equalizing CerrReporting While Disabled Reporting While Battery MonitoringTo view the present status of the banks Using a Generator As Source Power Page Troubleshooting To clean battery terminals Care and Maintenance1Indicator Light Sequences on the XC Series Indicator Light Flashing Sequences2Error Messages Error Messages on Remote DisplayErr Bat Symptom Problem SolvingFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Electrical Specifications Physical SpecificationsAC Input Specifications AC Input SpecificationsProtection Features Temperature SpecificationsEMC ApprovalsPage Limited Warranty for Warranty and Product InformationDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc