Operation
Table 3-1 Reading XC Series Status
| Remote |
| |
Charger Status | Display | Onboard Status Indicator Lights | |
|
|
|
|
Charging in bulk or absorption mode. |
| or | Charging indicator light illuminates |
Remote display shows scrolling display of charging |
|
|
|
state, battery voltage in volts and charging current in |
|
|
|
amps. |
|
|
|
Indicator lights indicate the charging current in % of |
|
|
|
full charge. At transition points when the current is |
|
|
|
changing, two indicator lights may flash alternately, |
|
|
|
then settle into the new charging current reading. | BUL |
|
|
|
|
|
|
Equalizing. |
|
| Charging indicator light flashes |
Charging indicator light flashes once every four |
|
|
|
seconds if bank 1 is being equalized, twice every four |
|
|
|
seconds if bank 2 is being equalized, and three times |
|
|
|
every four seconds if bank 3 is being equalized. | EQU |
|
|
|
|
|
|
Float mode of three stage charging or rest mode of |
| or | Ready indicator light illuminates |
two stage charging. |
|
|
|
All batteries have been fully charged. |
|
|
|
|
|
|
|
A battery has been disqualified while in float mode of |
| or | 25% current indicator light flashes |
three stage charging or rest mode of two stage | r |
|
|
charging. |
|
| |
| FLo |
|
|
| ABS |
|
|
A battery has been disqualified while in bulk or | dy |
| 25% current indicator light flashes |
absorption mode. |
|
| |
dis(example) | Fault indicator light illuminates | ||
Any fault condition that prevents the charger from |
| ||
charging one or more banks, but is not a charger |
| ||
failure. Remote display shows details of fault. |
| ||
| PoLBATERRR |
|
|
|