Xantrex Technology XC2524, XC5012, XC3012, XC1524 manual Problem Solving, Symptom

Page 65

Problem Solving

Problem Solving

If the remote display is not functioning, troubleshoot your XC Series using the tables below. In the event that you have a problem with your XC Series, the following tables will help you to identify the problem and offer possible solutions to the problem.

Symptom

Indicator lights do not illuminate when charger is connected to AC power.

Possible Cause

Solution

 

 

No power at AC source and no

Ensure that power is available at the source and a

battery connected on bank 1

battery or bank is connected on bank 1

Defective AC wiring

Replace wiring

Charger level fault

Call for service

Symptom

Fault indicator light illuminates. XC Series stops functioning.

Possible Cause

Solution

 

 

XC Series does not detect battery

Check quality of battery connection and wires.

for one of following reasons:

Ensure correct polarity (negative connected to

poor connection

negative, positive connected to positive).

reverse polarity connection

 

damaged wiring

 

XC Series internal temperature

Allow the XC Series to cool. Improve ventilation or

too hot

install in cooler location.

 

 

 

975-0187-01-01

4–7

Image 65
Contents Owner’s Guide Battery ChargerPage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Scope PurposeAudience OrganizationRelated Information Conventions UsedImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Operation TroubleshootingSpecifications Introduction XC Series provides the following protection features XC Series provides the following standard featuresXC Series XC Series AppearanceRemote Display Information Centers of the XC SeriesInformation Centers of the XC Series Onboard Status Panel CHfDescription Rear Panel5XC Series System Preparing for InstallationYou need the following materials Tools and MaterialsCondition Requirement Location6XC Series Mounting Orientations DC Wiring Wiring RequirementsOver-current protection disconnect AC WiringBattery Bank Size Requirements Installation Installation Sequence Installing the XC SeriesTo install DC wiring Pre-Installing DC WiringTo install AC wiring Pre-Installing AC WiringConductor Color code To connect AC wires with the crimp-on butt-splice connector To secure the display or blank plate on the unit Mounting the Remote DisplayTo remove the display To mount the XC Series MountingTo remotely mount the display Grounding Shows the connection order Final ConnectionsTo make the last DC connections Final DC ConnectionsTo make the last AC connections Powering UpTo install a BTS Installing Optional AccessoriesBattery Temperature Sensor To install rubber boots Drip Protection Rubber BootsTo configure the battery bank type Configuring the XC SeriesTo configure the charging type Operation Multiplex 3-Stage Charging About ChargingCharging Overview To force a battery detection sequenceSequential 2-Stage Charging Disqualified Batteries Temperature ConsiderationsPerform these disqualification checks in the order shown Things to be awareTo charge your batteries Charging BatteriesCharging Batteries About Equalizing Equalizing Flooded BatteriesTo equalize your batteries Performing An EqualizationThere are two ways to disable the XC Series Transitioning the XC Series to On, Disabled or OffThere are two ways to turn the XC Series on There is only one way to safely turn the XC Series offReading Remote Display and Onboard Status Indicator Lights Accessing Charger InformationABS Reporting While Charging or Equalizing CerrTo view the present status of the banks Reporting While Battery MonitoringReporting While Disabled Using a Generator As Source Power Page Troubleshooting To clean battery terminals Care and Maintenance1Indicator Light Sequences on the XC Series Indicator Light Flashing Sequences2Error Messages Error Messages on Remote DisplayErr Bat Symptom Problem SolvingFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Electrical Specifications Physical SpecificationsAC Input Specifications AC Input SpecificationsProtection Features Temperature SpecificationsEMC ApprovalsPage Limited Warranty for Warranty and Product InformationDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc