Xantrex Technology XC1524, XC5012, XC2524, XC3012 manual Err

Page 63

 

 

 

 

Error Messages on Remote Display

 

 

 

 

Table 4-2Error Messages

 

 

 

 

Onboard Status Panel

 

 

 

 

 

 

Display

 

Indicator lights

Fault

Solution

 

 

 

 

 

Err

 

Red fault indicator light

Battery Too

Allow batteries to warm up before

 

illuminated

Cold

attempting to charge again. Charging a

CLd

 

 

Green 10% indicator light

Shutdown

battery that has frozen is a potential

 

 

 

 

flashes

 

explosion hazard.

 

 

Display green bank indicator

 

 

 

 

light for affected battery bank

 

 

 

 

illuminated

 

 

 

 

 

 

 

DIS

 

25% current indicator light

Battery

Wait 15 minutes for the next battery

 

flashes

Disqualified

bank.

 

 

detection cycle. The warning may be

 

 

 

Warning

temporary.

 

 

 

 

Verify that the battery meets the minimum

 

 

 

 

AmpHour rating (XC1524: 30 Ah,

 

 

 

 

XC2524: 50 Ah, XC3012: 60 Ah,

 

 

 

 

XC5012: 100 Ah)

 

 

 

 

Try adding a small DC load.

 

 

 

 

Replace the battery.

 

 

Display green bank indicator

Over Voltage

Check battery. Do not charge a battery

 

 

light for the affected battery

Shutdown

rated at more than 12 volts nominal

 

 

bank illuminated

Warning

(XC3012, XC5012) or 24 volts nominal

 

 

 

 

(XC1524, XC2524).

 

 

 

 

Disconnect or turn off other charging

 

 

 

 

sources such as the alternator or the

 

 

 

 

charger on a generator with electric start.

 

 

 

 

If the warning level escalates without

 

 

 

 

being corrected, the XC Series enter the

 

 

 

 

fault level and stop charging the affected

 

 

 

 

 

HI

 

Red fault indicator light

Over Voltage

Check battery. Do not charge a battery

 

illuminated

Shutdown

rated at more than 12 volts nominal

 

Display green bank indicator

 

(XC3012, XC5012) or 24 volts nominal

 

light for the affected battery

 

(XC1524, XC2524).

 

bank illuminated

 

Disconnect or turn off other charging

 

 

 

sources such as the alternator or the

 

 

 

charger on a generator with electric start.

975HIErr-0187

 

-01-01

 

4–5

 

 

Image 63
Contents Owner’s Guide Battery ChargerPage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Organization PurposeScope AudienceRelated Information Conventions UsedImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Troubleshooting SpecificationsOperation Introduction XC Series provides the following protection features XC Series provides the following standard featuresXC Series XC Series AppearanceRemote Display Information Centers of the XC SeriesInformation Centers of the XC Series Onboard Status Panel CHfDescription Rear Panel5XC Series System Preparing for InstallationYou need the following materials Tools and MaterialsCondition Requirement Location6XC Series Mounting Orientations DC Wiring Wiring RequirementsOver-current protection disconnect AC WiringBattery Bank Size Requirements Installation Installation Sequence Installing the XC SeriesTo install DC wiring Pre-Installing DC WiringTo install AC wiring Pre-Installing AC WiringConductor Color code To connect AC wires with the crimp-on butt-splice connector Mounting the Remote Display To remove the displayTo secure the display or blank plate on the unit Mounting To remotely mount the displayTo mount the XC Series Grounding Shows the connection order Final ConnectionsTo make the last DC connections Final DC ConnectionsTo make the last AC connections Powering UpInstalling Optional Accessories Battery Temperature SensorTo install a BTS To install rubber boots Drip Protection Rubber BootsTo configure the battery bank type Configuring the XC SeriesTo configure the charging type Operation Multiplex 3-Stage Charging About ChargingTo force a battery detection sequence Sequential 2-Stage ChargingCharging Overview Disqualified Batteries Temperature ConsiderationsPerform these disqualification checks in the order shown Things to be awareTo charge your batteries Charging BatteriesCharging Batteries About Equalizing Equalizing Flooded BatteriesTo equalize your batteries Performing An EqualizationThere is only one way to safely turn the XC Series off Transitioning the XC Series to On, Disabled or OffThere are two ways to disable the XC Series There are two ways to turn the XC Series onReading Remote Display and Onboard Status Indicator Lights Accessing Charger InformationABS Reporting While Charging or Equalizing CerrReporting While Battery Monitoring Reporting While DisabledTo view the present status of the banks Using a Generator As Source Power Page Troubleshooting To clean battery terminals Care and Maintenance1Indicator Light Sequences on the XC Series Indicator Light Flashing Sequences2Error Messages Error Messages on Remote DisplayErr Bat Symptom Problem SolvingFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Electrical Specifications Physical SpecificationsAC Input Specifications AC Input SpecificationsProtection Features Temperature SpecificationsEMC ApprovalsPage Limited Warranty for Warranty and Product InformationDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc