Xantrex Technology XC1524, XC5012, XC2524, XC3012 manual Grounding

Page 35

Installing the XC Series

3.Secure the enclosed mounting template to the mounting surface with tape.

4.Drill the six pilot holes for the mounting screws, taking care that there is nothing behind the surface that can be damaged by the drill.

5.Mount the XC Series using corrosion resistant, #6 (3 mm) round, pan head (or similar) screws.

The top two keyhole-style mounting holes can be used to hold the XC Series in place while fastening the bottom four screws. For secure, permanent mounting, use all six mounting slots.

Grounding

WARNING: Electric shock hazard

Do not make an ungrounded installation. Have an electrician install a properly grounded circuit if one is not available. Improper connection can result in risk of an electric shock.

The XC Series Battery Charger must be grounded to reduce the risk of electrical shock. The AC input ground wire of the charger must be properly connected to ground in accordance with the applicable electrical codes, this is usually a ground terminal in the AC distribution panel where the branch circuit originates.

Xantrex recommends that you install a DC chassis ground (earth) from the ground stud on the XC Series to the engine negative bus or DC ground bus. The DC chassis ground (earth) should not be more than one size smaller than the power conductors, and must be rated for the battery fuses that are used to protect the DC wiring. Refer to your local electrical codes to verify if this is required in your jurisdiction or in your application.

Proceed to “Final Connections”.

975-0187-01-01

2–9

Image 35
Contents Owner’s Guide Battery ChargerPage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Organization PurposeScope AudienceRelated Information Conventions UsedImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Operation TroubleshootingSpecifications Introduction XC Series provides the following protection features XC Series provides the following standard featuresXC Series XC Series AppearanceRemote Display Information Centers of the XC SeriesInformation Centers of the XC Series Onboard Status Panel CHfDescription Rear Panel5XC Series System Preparing for InstallationYou need the following materials Tools and MaterialsCondition Requirement Location6XC Series Mounting Orientations DC Wiring Wiring RequirementsOver-current protection disconnect AC WiringBattery Bank Size Requirements Installation Installation Sequence Installing the XC SeriesTo install DC wiring Pre-Installing DC WiringTo install AC wiring Pre-Installing AC WiringConductor Color code To connect AC wires with the crimp-on butt-splice connector To secure the display or blank plate on the unit Mounting the Remote DisplayTo remove the display To mount the XC Series MountingTo remotely mount the display Grounding Shows the connection order Final ConnectionsTo make the last DC connections Final DC ConnectionsTo make the last AC connections Powering UpTo install a BTS Installing Optional AccessoriesBattery Temperature Sensor To install rubber boots Drip Protection Rubber BootsTo configure the battery bank type Configuring the XC SeriesTo configure the charging type Operation Multiplex 3-Stage Charging About ChargingCharging Overview To force a battery detection sequenceSequential 2-Stage Charging Disqualified Batteries Temperature ConsiderationsPerform these disqualification checks in the order shown Things to be awareTo charge your batteries Charging BatteriesCharging Batteries About Equalizing Equalizing Flooded BatteriesTo equalize your batteries Performing An EqualizationThere is only one way to safely turn the XC Series off Transitioning the XC Series to On, Disabled or OffThere are two ways to disable the XC Series There are two ways to turn the XC Series onReading Remote Display and Onboard Status Indicator Lights Accessing Charger InformationABS Reporting While Charging or Equalizing CerrTo view the present status of the banks Reporting While Battery MonitoringReporting While Disabled Using a Generator As Source Power Page Troubleshooting To clean battery terminals Care and Maintenance1Indicator Light Sequences on the XC Series Indicator Light Flashing Sequences2Error Messages Error Messages on Remote DisplayErr Bat Symptom Problem SolvingFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Electrical Specifications Physical SpecificationsAC Input Specifications AC Input SpecificationsProtection Features Temperature SpecificationsEMC ApprovalsPage Limited Warranty for Warranty and Product InformationDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc