Troubleshooting
Symptom
Fault indicator light flashes. XC Series stops functioning.
Possible Cause | Solution |
|
|
XC Series hardware failure | Call for service |
|
|
Symptom
Fault indicator light illuminates. 100% indicator light flashes.
Possible Cause | Solution |
|
|
Battery temperature is too hot for | Allow battery to cool. Improve ventilation or |
safe charging. | install in cooler location. It may indicate a shorted |
| cell in the battery or excessive water loss. |
|
|
Symptom
Fault indicator light illuminates. 10% indicator light flashes.
Possible Cause | Solution |
|
|
Battery temperature is too cold for | Allow batteries to warm up before attempting to |
safe charging. | charge again. Charging a battery that has frozen is |
| a potential explosion hazard. |
|
|
Symptom
XC Series completes a charging cycle, but the battery voltage seems (about 2 volts) too low.
Possible Cause | Solution |
|
|
Battery has a shorted cell. | Check the battery. |
| Verify you are attempting to charge a battery correctly |
| rated at 12 volts nominal (XC3012, XC5012) or 24 |
| volts nominal (XC1524, XC2524). |
| battery voltage with all loads removed and the battery |
| is at rest for about an hour. |
|
|