Xantrex Technology XC3012, XC5012, XC2524 manual Physical Specifications, Electrical Specifications

Page 70

Specifications

Physical Specifications

Dimensions

Base unit:

367 mm x 240 mm x 106 mm

 

 

14.45 in. x 9.45 in. x 4.17 in.

 

Remote Display:

118 mm x 41 mm x 32 mm

 

 

4.65 in. x 1.6 in. x 1.26 in.

 

 

 

Weight

5.7 kg (12.6 lbs)

 

 

 

AC input connections

Two color-coded No. 16 AWG wires (L, N) and one

 

No. 18 AWG (G) minimum 152 mm (6 in.) long in a separate

 

AC wiring enclosure with 21.3 mm (0.84 in.) hole provision for

 

connection of a ½ inch North American "trade size" cable clamp

 

or conduit hub or international PG 13.5 or PG16 or M20 gland or

 

cable strain relief fitting.

 

 

DC output connections

Four right-angle M6 studs (3 positives and 1 common

 

negative) for battery cable ring terminals and one M6 mm DC

 

equipment ground

 

 

 

Electrical Specifications

Number of battery bank outputs

3 isolated, independently controlled outputs

 

 

 

 

 

 

Nominal battery voltage

12 V units:

12

VDC

 

 

 

24 V units:

24

VDC

 

 

 

 

 

 

 

Normal operating output range

12 V units:

0 – 16 VDC

 

 

 

24 V units:

0 – 32 VDC

 

 

 

 

 

 

 

Nominal operating AC voltage

110 – 240 VAC

 

 

 

 

 

 

 

 

Rated DC output current (total)

XC3012:

30

A (up to 15 V)

 

 

XC5012:

50

A (up to 15 V)

 

 

XC1524:

15

A (up to 30 V)

 

 

XC2524:

25

A (up to 30 V)

 

 

 

 

 

 

Absorption voltage (in VDC for

 

50 °C (122 °F)

25 °C (77 °F)

<0 °C (32 °F)

XC3012 and XC5012)

Flooded

 

13.7

14.4

15.1

(Multiply VDC by 2 to get the

Gel

 

13.5

14.2

14.9

absorption voltage for XC1524

AGM

 

13.8

14.3

14.8

and XC2524)

Lead-calcium

14.8

15.5

16.0

 

 

 

 

 

 

A–2

975-0187-01-01

Image 70
Contents Battery Charger Owner’s GuidePage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Audience PurposeScope OrganizationConventions Used Related InformationImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Specifications TroubleshootingOperation Introduction XC Series provides the following standard features XC Series provides the following protection featuresXC Series Appearance XC SeriesInformation Centers of the XC Series Remote DisplayInformation Centers of the XC Series CHf Onboard Status PanelRear Panel DescriptionPreparing for Installation 5XC Series SystemTools and Materials You need the following materialsLocation Condition Requirement6XC Series Mounting Orientations Wiring Requirements DC WiringAC Wiring Over-current protection disconnectBattery Bank Size Requirements Installation Installing the XC Series Installation SequencePre-Installing DC Wiring To install DC wiringPre-Installing AC Wiring To install AC wiringConductor Color code To connect AC wires with the crimp-on butt-splice connector To remove the display Mounting the Remote DisplayTo secure the display or blank plate on the unit To remotely mount the display MountingTo mount the XC Series Grounding Final Connections Shows the connection orderFinal DC Connections To make the last DC connectionsPowering Up To make the last AC connectionsBattery Temperature Sensor Installing Optional AccessoriesTo install a BTS Drip Protection Rubber Boots To install rubber bootsConfiguring the XC Series To configure the battery bank typeTo configure the charging type Operation About Charging Multiplex 3-Stage ChargingSequential 2-Stage Charging To force a battery detection sequenceCharging Overview Temperature Considerations Disqualified BatteriesThings to be aware Perform these disqualification checks in the order shownCharging Batteries To charge your batteriesCharging Batteries Equalizing Flooded Batteries About EqualizingPerforming An Equalization To equalize your batteriesThere are two ways to turn the XC Series on Transitioning the XC Series to On, Disabled or OffThere are two ways to disable the XC Series There is only one way to safely turn the XC Series offAccessing Charger Information Reading Remote Display and Onboard Status Indicator LightsABS Cerr Reporting While Charging or EqualizingReporting While Disabled Reporting While Battery MonitoringTo view the present status of the banks Using a Generator As Source Power Page Troubleshooting Care and Maintenance To clean battery terminalsIndicator Light Flashing Sequences 1Indicator Light Sequences on the XC SeriesError Messages on Remote Display 2Error MessagesErr Bat Problem Solving SymptomFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Physical Specifications Electrical SpecificationsAC Input Specifications AC Input SpecificationsTemperature Specifications Protection FeaturesApprovals EMCPage Warranty and Product Information Limited Warranty forDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc