Xantrex Technology XC1524, XC5012, XC2524, XC3012 manual AC Input Specifications

Page 71

AC Input Specifications

Float voltage (in VDC for XC3012

 

50 °C (122 °F)

25 °C (77 °F)

<0 °C (32 °F)

and XC5012)

Flooded

12.8

13.5

14.2

(Multiply VDC by 2 to get the

Gel

13.1

13.8

14.5

float voltage for XC1524 and

AGM

12.9

13.4

13.9

XC2524)

Lead-calcium 12.8

13.5

14.2

 

 

 

 

Equalize mode current

50% rated output

 

 

 

 

 

 

 

Equalize mode—maximum output

XC3012:

16.0 VDC

 

 

voltage

XC5012:

16.0 VDC

 

 

 

XC1524:

32.0 VDC

 

 

 

XC2524:

32.0 VDC

 

 

 

 

 

 

 

Off-state current draw (with

XC3012:

<20 mA

 

 

remote installed)

XC5012:

<20 mA

 

 

 

XC1524:

<15 mA

 

 

 

XC2524:

<15 mA

 

 

 

 

 

 

 

AC Input Specifications

AC input voltage range

100 – 260 VAC at full power

 

 

90

– 105 VAC at 80% restricted load

 

 

Note: Charger may not start with input voltage

 

<100 VAC

 

 

 

 

 

 

 

 

Maximum AC input current

at 100 VAC

 

at 184 VAC

 

 

XC3012:

6 AAC

XC3012:

4.3 AAC

 

XC5012:

10 AAC

XC5012:

5.7 AAC

 

XC1524:

6 AAC

XC1524:

4.3 AAC

 

XC2524:

10 AAC

XC2524:

5.7 AAC

 

 

 

 

 

Power factor at rated load

0.95

 

 

 

 

 

 

 

 

 

Frequency

47

– 63 Hz

 

 

 

 

 

 

Efficiency – peak

12

V units: 80% @ 120 VAC, 83% @ 230 VAC

 

24

V units: 85% @ 120 VAC, 87% @ 230 VAC

 

 

Surge protection

Line-to-neutral surge protector rated at 275 VAC

 

 

 

 

 

 

975-0187-01-01

A–3

Image 71
Contents Owner’s Guide Battery ChargerPage Xantrex XC3012, XC5012 XC1524 and XC2524 Battery Charger Date and Revision Organization PurposeScope AudienceRelated Information Conventions UsedImportant Safety Instructions Explosive Gas and Battery Precautions FCC Information Viii Contents Operation TroubleshootingSpecifications Introduction XC Series provides the following protection features XC Series provides the following standard featuresXC Series XC Series AppearanceRemote Display Information Centers of the XC SeriesInformation Centers of the XC Series Onboard Status Panel CHfDescription Rear Panel5XC Series System Preparing for InstallationYou need the following materials Tools and MaterialsCondition Requirement Location6XC Series Mounting Orientations DC Wiring Wiring RequirementsOver-current protection disconnect AC WiringBattery Bank Size Requirements Installation Installation Sequence Installing the XC SeriesTo install DC wiring Pre-Installing DC WiringTo install AC wiring Pre-Installing AC WiringConductor Color code To connect AC wires with the crimp-on butt-splice connector To secure the display or blank plate on the unit Mounting the Remote DisplayTo remove the display To mount the XC Series MountingTo remotely mount the display Grounding Shows the connection order Final ConnectionsTo make the last DC connections Final DC ConnectionsTo make the last AC connections Powering UpTo install a BTS Installing Optional AccessoriesBattery Temperature Sensor To install rubber boots Drip Protection Rubber BootsTo configure the battery bank type Configuring the XC SeriesTo configure the charging type Operation Multiplex 3-Stage Charging About ChargingCharging Overview To force a battery detection sequenceSequential 2-Stage Charging Disqualified Batteries Temperature ConsiderationsPerform these disqualification checks in the order shown Things to be awareTo charge your batteries Charging BatteriesCharging Batteries About Equalizing Equalizing Flooded BatteriesTo equalize your batteries Performing An EqualizationThere is only one way to safely turn the XC Series off Transitioning the XC Series to On, Disabled or OffThere are two ways to disable the XC Series There are two ways to turn the XC Series onReading Remote Display and Onboard Status Indicator Lights Accessing Charger InformationABS Reporting While Charging or Equalizing CerrTo view the present status of the banks Reporting While Battery MonitoringReporting While Disabled Using a Generator As Source Power Page Troubleshooting To clean battery terminals Care and Maintenance1Indicator Light Sequences on the XC Series Indicator Light Flashing Sequences2Error Messages Error Messages on Remote DisplayErr Bat Symptom Problem SolvingFault indicator light flashes. XC Series stops functioning Rdy Page Specifications Electrical Specifications Physical SpecificationsAC Input Specifications AC Input SpecificationsProtection Features Temperature SpecificationsEMC ApprovalsPage Limited Warranty for Warranty and Product InformationDisclaimer of Warranty Return Material Authorization Policy Information About Your System Page Xantrex Technology Inc