5.Run the compressor for 15 minutes.

6.After 15 minutes, close the drain valve by turning clockwise. The tank will fill to cut-outpressure and the motor will stop.

7.Compressed air will be available until it is used or bled off.

OPERATING PROCEDURES

Start-up (Fig. 1)

1.Follow Pre-Start Checklist under Preparation for Use.

CAUTION: Risk of unsafe operation. Do not operate in upright position. Upright position is for storage only.

2.Move the On/Off switch to the ON position and allow tank pres- sure to build. Motor will stop when tank pressure reaches cut-outpressure.

CAUTION: Risk of unsafe operation. Compressed air from the unit may contain water condensation and oil mist. Do not spray unfil- tered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instruc- tions for the air tool or device.

3.Adjust regulator (F) to desired setting. See Regulator under Features.

Shut-down (Fig. 1)

1.Move On/Off switch (L) to the OFF position. NOTE: If finished using compressor, follow Steps 2 – 6.

2.Turn regulator knob (F) counterclockwise until fully closed. Ensure regulated pressure gauge reads 0 PSI (0 kPa).

3.Remove hose and accessory.

4.Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure gauge reads 0 PSI (0 kPa).

WARNING: Risk of bursting. Drain air tank daily. Water will con- dense in air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

5.Allow the compressor to cool down.

6.Wipe air compressor clean and store in a safe, non-freezing area.

CAUTION: Risk of unsafe operation. Do not operate in upright position. Upright position is for storage only.

MAINTENANCE

The following procedures must be followed when maintenance or service is performed on the air compressor.

1.Ensure On/Off switch is in the OFF position.

2.Remove air compressor plug from outlet.

3.Drain air tank.

4.Allow air compressor to cool down before starting service. NOTE: All compressed air systems contain maintenance parts (e.g., oil, filters, separators) that are periodically replaced. These used parts may contain substances that are regulated and must be disposed of in accordance with local, state, and federal laws and regulations. NOTE: Take note of the positions and locations of parts during disassembly to make reassembly easier.

NOTE: Any service operations not included in this section should be performed by a DEWALT factory service center or a DEWALT authorized service center.

English

13

Image 13
Contents D55146 Pump/Motor Specifications D55146 Air CompressorSpecifications Declared Noise Emission Values per ISO3744Important Safety Instructions Definitions Safety GuidelinesHOW to Prevent IT Save These InstructionWhat can Happen HOW to Prevent IT Tires Attachments & accessoriesProperty damage Correct tire pressureEnglish Attempting to operate Never defeat the safety feaTo repair compressor with Can expose you to movingRized parts For Future USENever stand on CompressorFeatures Fig Assembly Fig InstallationGrounding Instructions Extension CordsCompatibility Location Voltage and Circuit ProtectionTransporting LiftingBREAK-IN Procedure Pre-Start Checklist FigPreparation for USE Initial Set-up FigMaintenance Operating ProceduresFollow Pre-Start Checklist under Preparation for Use Start-up FigChecking Safety Valve Fig Maintenance ChartProcedure Daily Weekly Monthly Year or Checking Air Filter Element FigFull One Year Warranty Accessories Service InformationRepairs Date and Place of PurchaseGlossary Troubleshooting Codes Troubleshooting GuideProblem Code Code Possible Cause Possible SolutionWhile accessory is being used Under Features if pressure drop is excessiveUsed Extension Cords under Installation Fiche technique de la pompe/du moteur Compresseur d’air D55146Fiche technique Directives de sécurité importantes Définitions lignes directrices en Matière de sécuritéConserver CES Directives CE QUI Peut SE Produire Avertissement Risque D’ÉCLATEMENT Comment L’ÉVITERPneus AccessoiresLe manomètre pour empêcher un surgonflage Mise à la terre Avertissement Risque DE Choc ÉlectriqueÉlectrique le fait de Avertissement Risque Provenant DES Objets Projetés EN L’AIRAvertissement Attention Surfaces Chaudes Avertissement Risque Associé AUX Pièces MobilesAvertissement Risque DE Chute Avertissement Risque Associé À Utilisation DangereuseCaractéristiques Conserver CES Directives Pour UN Usage UltérieurAvertissement Risque DE Blessure EN Soulevant LE Produit Mise EN Garde Risque Associé AU BruitDirectives relatives à la mise à la terre Assemblage FigProtection de la tension et du circuit RallongesCompatibilité EmplacementTransport ÉlectricitéListe de vérification de pré-démarrage Fig Mode D’EMPLOIRéglage initial Fig Procédure DE RodageArrêt Fig Procédures DE Fonctionnement Démarrage FigEntretien Vérification de la soupape de sûreté Fig Programme d’entretienVérification des éléments du filtre d’air Fig Vidange du réservoir d’air Fig AccessoiresInformation sur les réparations Garantie complète d’un 1 an RéparationsGlossaire Guide de dépannage Code Cause Possible Solution PossibleCodes de dépannage Problème CodeDe travail avec l’utilisation de l’accessoire Il est normal que la pression chute lorsqu’un accessoi’utilisation de l’accessoire Ne serrez pas tropInflammables Tion de peinture. Lire lavertissement concernant les vapeursAgréé Dewalt Réparation en usine de Dewalt ou un centre de réparationEspecificaciones de la Bomba y el Motor Compresor de aire D55146Especificaciones Valores de emisión de ruido declarados según ISO3744Guarde Estas Instrucciones Instrucciones de seguridad importantesPeligro Riesgo DE Explosión O Incendio ¿QUÉ Puede SUCEDER?Peligro Riesgo Respiratorio Asfixia Elementos y accesorios Advertencia Riesgo DE ExplosiónLa presión de éstos antes NeumáticosAdvertencia Riesgo DE Descarga Eléctrica NeumáticoAdvertencia Riesgo DE Superficies Calientes Advertencia Riesgo DE Objetos Despedidos¿QUÉ Puede SUCEDER? Advertencia Riesgo POR Piezas Móviles¿QUÉ Puede SUCEDER? Cómo Evitarlo Advertencia Riesgo DE Lesión POR Levantar Mucho Peso Conserve Estas Instrucciones Para Futuras ConsultasAdvertencia Riesgo DE Caídas Cómo EvitarloCaracterísticas Fig Instalación Instrucciones de conexión a tierraEnsamblaje Fig Voltaje y protección del circuito Cables prolongadoresCompatibilidad Preparación Para EL USO LugarLista de control previa a la puesta en marcha Fig Procedimientos Operativos Puesta en marcha Fig Configuración inicial FigProcedimiento DE Puesta EN Marcha Inicial Mantenimiento Apagado FigControlar la válvula de seguridad Fig Tabla de mantenimientoControlar el elemento del filtro de aire Fig Procedimiento Diaria Semanal Mensual Vez alAccesorios Drenar el tanque de aire FigInformación DEL Servicio Técnico ReparacionesVILLAHERMOSA, TAB Garantía completa de un añoGlosario Códigos de detección de problemas Guía de detección de problemasProblema Código Código Causa Posible Solución PosibleSi la válvula aún pierde, debe ser reemplazada Jabonosa. No ajuste demasiadoEs normal que se presente alguna caída de presión cuando AccesorioSobre vapor inflamable InstalaciónDel interruptor de presión Page OCT06 Form No. A18765 D55146 Copyright 2006 D Ewalt Ewalt Industrial Tool Co., 701 Joppa Road, Baltimore, MD