CODE | POSSIBLE CAUSE | POSSIBLE SOLUTION |
|
|
|
17 | Detergent type oil being used in pump | Drain oil and refill pump with DEWALT synthetic compressor |
|
| oil. |
|
|
|
18 | Extension cord is wrong length or gauge | Check for proper gauge wire and cord length. See |
|
| Extension Cords under Installation. |
|
|
|
19 | Loose electrical connections | Contact a DEWALT factory service center or a DEWALT |
|
| authorized service center. |
|
|
|
20 | Possible defective motor or starting capacitor | Contact a DEWALT factory service center or a DEWALT |
|
| authorized service center. |
|
|
|
21 | Paint spray on internal motor parts | Contact a DEWALT factory service center or a DEWALT |
|
| authorized service center. Do not operate the compressor in |
|
| the paint spray area. See flammable vapor warning. |
|
|
|
22 | Fuse blown, circuit breaker tripped | 1. Check fuse box for blown fuse and replace as necessary. |
|
| Reset circuit breaker. Do not use a fuse or circuit breaker |
|
| with higher rating than that specified for your particular |
|
| branch circuit. |
|
| 2. Check for proper fuse. Use only a time delay fuse. |
|
| 3. Check for low voltage conditions and/or proper extension |
|
| cord. |
|
| 4. Disconnect the other electrical appliances from circuit or |
|
| operate the compressor on its own branch circuit. |
|
|
|
23 | Tank pressure exceeds pressure switch | Motor will start automatically when tank pressure drops |
|
| below |
|
|
|
24 | Pressure release valve on pressure switch has not | Set the On/Off switch to OFF. If the valve does not open, |
| unloaded head pressure | replace switch. Contact a DEWALT factory service center or |
|
| a DEWALT authorized service center. |
English