Porter-Cable CPF6025VP Description of Operation, Air Intake Filter not shown This filter is

Page 7
Fig. 1

DESCRIPTION OF OPERATION

Drain Valve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use.

Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector. If the motor overheats for any reason, the thermal overload protector will shut off the motor. The motor must be allowed to cool before restarting.

ON/AUTO - OFF Switch (A) Fig. 1: Turn

 

 

B

 

E

 

 

D

this switch ON to provide automatic power

 

 

 

 

 

 

 

 

to the pressure switch and OFF to remove

 

 

 

 

 

 

 

 

power at the end of each use.

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

Air Intake Filter (not shown): This filter is

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

designed to clean air coming into the pump.

 

 

 

 

 

 

 

 

This filter must always be clean and

 

 

 

 

 

 

 

 

ventilation openings free from obstructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

 

See "Maintenance".

C

 

 

 

 

 

 

 

 

 

 

 

 

Air Compressor Pump (not shown): To compress air, the piston moves up and down in the cylinder. On the downstroke,

air is drawn in through the air intake valves. The exhaust valve remains closed. On the upstroke of the piston, air is compressed. The intake valves close and compressed air is forced out through the exhaust valve, into the outlet tube, through the check valve and into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Check Valve (not shown): When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.

Pressure Release Valve (not shown): The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches “cut-out” pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches cut-out pressure.

Pressure Switch (B) Fig. 1: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set “cut-in” pressure. It stops the motor when the air tank pressure reaches the factory set “cut-out” pressure.

Safety Valve (C) Fig. 1: If the pressure switch does not shut off the air compressor at its cut-out pressure setting, the safety valve will protect against high pressure by “popping out” at its factory set pressure (slightly higher than the pressure switch cut-out setting).

Outlet Pressure Gauge (D) Fig. 1: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge (E) Fig. 1: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator (F) Fig. 1: The air pressure coming from the air tank is controlled by the regulator knob. Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure. To avoid minor readjustment after making a change in pressure setting, always approach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than that desired, then bring up to the desired pressure. Depending on the air requirements of each particular accessory, the outlet regulated air pressure may have to be adjusted while you are operating the accessory.

7-ENG

Image 7
Contents To learn more about Porter-Cable Visit our website at Instruction Oilfree Manual CompressorsImportant Safety Instructions Safety Guidelines DefinitionsRead and Follow ALL Instructions Risk of Bursting Risk of Explosion or Fire What can Happen HOW to Prevent ITWhat can Happen HOW to Prevent IT HazardRisk to Breathing What can Happen HOW to Prevent IT Risk from Flying Objects What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of Property Damage When Transporting Compressor Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Burns What can Happen HOW to Prevent IT Risk of Falling What can Happen HOW to Prevent ITCPF6025VP SpecificationsGlossary Duty CycleAir Intake Filter not shown This filter is Description of OperationLubrication and Oil InstallationInstalling Wheels, and Rubber Feet Fig Location of the Air CompressorDo not USE AN Adapter Voltage and Circuit ProtectionPiping Additional Regulators and ControlsOperating Procedures BREAK-IN ProceduresDaily Start-Up Checklist Safety Valve Inspection MaintenanceService Instructions Air Filter Inspection and ReplacementStorage Motor Wiring DiagramMotor OVER-TIGHTEN Troubleshooting GuideProblem Cause Correction 15-ENG Accessories 17-ENG This Warranty is not Transferable and does not Cover Limited WarrantyPara obtener más información Sobre Porter-Cable Manual de InstruccionesInstrucciones Importantes DE Seguridad Definiciones DE Normas DE SeguridadLEA Y Siga Todas LAS Instrucciones Riesgo DE Explosión PeligroGuarde Estas Instrucciones ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO?Riesgo DE Inhalación ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Riesgo DE Caidas ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO?Model No GlosarioCiclo DE Trabajo EspecificacionesInterruptor ON/Auto-OFF a Colocar Descripción DE LA OperaciónVoltaje y Protección de los Circuitos Montaje Del Compresor de Aire FigUbicación del Compresor de Aire Aceite y LubricaciónTuberías Instrucciones Para Conectar a TierraControles y Reguladores Adicionales Procedimientos para el Asentamiento Procedimientos Para OperarEl procedimiento Filtro de Aire Inspección y Reemplazo MantenimientoInstrucciones Para EL Servicio Program de Mantenimiento RutinarioAlmacenaje Motor Diagrama de Cables para el ReemplazoNota Guía Para Diagnóstico DE ProblemasProblema Causa Solución SobreajustarEl motor no funciona o no El interruptor de protección de Posible defecto en la válvula de FILTROS, REGULADORES, Lubricadores AccesoriosNotas Esta Garantía no ES Transferible Y no Cubre Garantía LimitadaManuel d’instructions Mesures DE Sécurité Importantes Mesures DE Sécurité DéfinitionsLisez ET Suivez Toutes LES Consignes Risque D’ÉCLATEMENT Risque D’EXPLOSION OU D’INCENDIE PréventionRisque Prévention Risque PAR Inhalation Prévention Risque DE Projection D’OBJETS PréventionRisque DE Choc Électrique Prévention Risque DE Brûlures Prévention Risque Relié AUX Pièces Mobiles PréventionRisque DE Chute Prévention Cycle Opératoire LexiqueModèle No Filtre d’admission d’air non indiqué Ce filtre Description DU Mode OpérationnelPompe du compresseur d’air non indiqué Huile et lubrification Emplacement du compresseur d’airAssemblage Assemblage du Compressur D’Air SchémaSchéma Commandes et régulateurs supplémentairesTension et protection du circuit TuyauxUne fois que vous avez terminé Procédures OpérationnellesProcédures de mise en route Liste de vérification quotidienne de mise en marcheHoraire quotidien d’entretien Filtre à air Vérification et remplacementEntretien Directives D’ENTRETIENMoteur Remplacement du moteur Diagramme sur le câblageRemplacement EntreposageProbléme Cause Correction Guide DE DépannageLe moteur ne tourne pas Déclencheur thermique à surmenage Pour les exigences d’air FILTRES, RÉGULATEURS, Graisseurs Accessoires53-FR 54-FR Garantie Limitée Porter-Cable Corporation Highway 45 North Box Jackson, TN