GLOSSARY

CFM: Cubic feet per minute.

SCFM: Standard cubic feet per minute; a unit of measure of air delivery.

PSIG: Pounds per square inch gauge; a unit of measure of pressure.

ASME: American Society of Mechanical Engineers; made, tested, inspected and registered to meet the standards of ASME.

California Code: Unit may comply with California Code 462 (l) (2)/(M) (2). Specification/model label is on the side of the tank on units that comply with California Code.

Cut-In Pressure: While the motor is off, air tank pressure drops as you continue to use your accessory or air tool. When the tank pressure drops to a certain low level the motor will restart automatically. The low pressure at which the motor automatically restarts is called “cut-in pressure.”

Cut-Out Pressure: When you turn on your air compressor and it begins to run, air pressure in the air tank begins to build. It builds to a certain high pressure before the motor automatically shuts off - protecting your air tank from pressure higher than its capacity. The high pressure at which the motor shuts off is called “cut-out pressure.”

Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified independent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety.

DUTY CYCLE

Porter-Cable air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because the air compressor is undersized for the required air demand. Maximum compressor pumping time per hour is 30 minutes.

SPECIFICATIONS

Model No.

CPF6025VP

Horsepower Peak

6.0

Bore

2.375"

Stroke

1.35"

* Voltage/Hertz/Phase

120/60/1

** Minimum Branch Circuit Requirement

15 amps

* Fuse Type

Time Delay

Amperage at Max. Load

15 Amp

Air Tank Capacity (Gallon)

25

Approximate Cut-in Pressure

110 PSIG

Approximate Cut-out Pressure

135 PSIG

SCFM @ 40 PSIG

8.3

SCFM @ 90 PSIG

5.8

* This air compressor can be operated on a 15 amp circuit if:

1.Voltage supply to circuit is normal.

2.Circuit is not used to supply any other electrical needs (lights, appliances, etc.)

3.Extension cords comply with specifications in owners manual.

4.Circuit is equipped with 15 amp circuit breaker or 15 amp time delay fuse.

If any of the above conditions cannot be met, or if operation of the air compressor repeatedly causes interruption of the power it may be necessary to operate it from a 20 amp circuit. It is not necessary to change the cord set.

**A circuit breaker is preferred. Use only a fuse or circuit breaker that is the same rating as the branch circuit on which the air compressor is operated. If the air compressor is connected to a circuit protected by fuses, use dual element time delay fuses.

6-ENG

Image 6
Contents Instruction Oilfree Manual Compressors To learn more about Porter-Cable Visit our website atSafety Guidelines Definitions Important Safety InstructionsRead and Follow ALL Instructions Hazard Risk of Explosion or Fire What can Happen HOW to Prevent IT What can Happen HOW to Prevent IT Risk of BurstingRisk from Flying Objects What can Happen HOW to Prevent IT Risk to Breathing What can Happen HOW to Prevent ITRisk of Electrical Shock What can Happen HOW to Prevent IT Risk of Falling What can Happen HOW to Prevent IT Risk from Moving Parts What can Happen HOW to Prevent ITRisk of Burns What can Happen HOW to Prevent IT Risk of Property Damage When Transporting CompressorDuty Cycle SpecificationsGlossary CPF6025VPDescription of Operation Air Intake Filter not shown This filter isLocation of the Air Compressor InstallationInstalling Wheels, and Rubber Feet Fig Lubrication and OilAdditional Regulators and Controls Voltage and Circuit ProtectionPiping Do not USE AN AdapterBREAK-IN Procedures Operating ProceduresDaily Start-Up Checklist Air Filter Inspection and Replacement MaintenanceService Instructions Safety Valve InspectionMotor Wiring Diagram StorageMotor Troubleshooting Guide OVER-TIGHTENProblem Cause Correction 15-ENG Accessories 17-ENG Limited Warranty This Warranty is not Transferable and does not CoverManual de Instrucciones Para obtener más información Sobre Porter-CableDefiniciones DE Normas DE Seguridad Instrucciones Importantes DE SeguridadLEA Y Siga Todas LAS Instrucciones ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? PeligroGuarde Estas Instrucciones Riesgo DE ExplosiónRiesgo DE Inhalación ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO? Riesgo DE Caidas ¿QUÉ Puede OCURRIR? ¿CÓMO PREVENIRLO?Especificaciones GlosarioCiclo DE Trabajo Model NoDescripción DE LA Operación Interruptor ON/Auto-OFF a ColocarAceite y Lubricación Montaje Del Compresor de Aire FigUbicación del Compresor de Aire Voltaje y Protección de los CircuitosInstrucciones Para Conectar a Tierra TuberíasControles y Reguladores Adicionales Procedimientos Para Operar Procedimientos para el AsentamientoEl procedimiento Program de Mantenimiento Rutinario MantenimientoInstrucciones Para EL Servicio Filtro de Aire Inspección y ReemplazoMotor Diagrama de Cables para el Reemplazo AlmacenajeSobreajustar Guía Para Diagnóstico DE ProblemasProblema Causa Solución NotaEl motor no funciona o no El interruptor de protección de Posible defecto en la válvula de Accesorios FILTROS, REGULADORES, LubricadoresNotas Garantía Limitada Esta Garantía no ES Transferible Y no CubreManuel d’instructions Mesures DE Sécurité Définitions Mesures DE Sécurité ImportantesLisez ET Suivez Toutes LES Consignes Risque D’EXPLOSION OU D’INCENDIE Prévention Risque D’ÉCLATEMENTRisque Prévention Risque DE Projection D’OBJETS Prévention Risque PAR Inhalation PréventionRisque DE Choc Électrique Prévention Risque Relié AUX Pièces Mobiles Prévention Risque DE Brûlures PréventionRisque DE Chute Prévention Lexique Cycle OpératoireModèle No Description DU Mode Opérationnel Filtre d’admission d’air non indiqué Ce filtrePompe du compresseur d’air non indiqué Assemblage du Compressur D’Air Schéma Emplacement du compresseur d’airAssemblage Huile et lubrificationTuyaux Commandes et régulateurs supplémentairesTension et protection du circuit SchémaListe de vérification quotidienne de mise en marche Procédures OpérationnellesProcédures de mise en route Une fois que vous avez terminéDirectives D’ENTRETIEN Filtre à air Vérification et remplacementEntretien Horaire quotidien d’entretienEntreposage Remplacement du moteur Diagramme sur le câblageRemplacement MoteurGuide DE Dépannage Probléme Cause CorrectionLe moteur ne tourne pas Déclencheur thermique à surmenage Pour les exigences d’air Accessoires FILTRES, RÉGULATEURS, Graisseurs53-FR 54-FR Garantie Limitée Porter-Cable Corporation Highway 45 North Box Jackson, TN