DeWalt DW079 instruction manual Height of Instrument Alert, Remote Control SPEED/ROTATION Button

Page 15

In Manual Mode:

The arrow buttons (O) are used to tilt the laser head up or down in the X or Y directions as marked on the protective roll cage of the laser unit.

REMOTE CONTROL: SPEED/ROTATION BUTTON

The speed/rotation button (Q) is used to adjust the speed of the laser beam through its 4 preset speeds.

NOTE: The speed/rotation button performs the same function as the speed/rotation button on the control panel of the laser unit.

REMOTE CONTROL: SCAN MODE BUTTON

The scan mode button (R) is used to make the laser head sweep back and forth, creating a short, bright laser line. This short line is much brighter and more visible than when the unit is in full rotation mode.

Using Scan Mode:

To enter Scan Mode, push and release the scan mode button. To exit Scan Mode, push and release the button again.

The size and direction of the scan zone can be controlled with the arrow buttons on the laser unit control panel or the remote control. For a more detailed explanation, refer to Arrow Buttons under Laser Control Panel Buttons.

IMPORTANT: The remote control cannot be used for User Defined Scan Mode.

REMOTE CONTROL: PUBLIC AND PRIVATE MODE

The DW079 Rotary Laser and the DW0794 Remote Control each have the capability to operate in either Public Mode or Private Mode. For the laser and the remote control to work together, they must both be set to the same mode.

Public Mode

The remote control sends signals that can potentially be received by multiple laser units as well as other models of

13

laser units. This is the normal, default operating mode for the DW0794 remote control.

To activate Public Mode:

Press and hold the speed/rotation button (Q) (open padlock symbol beside the button) for 4 seconds.

After an 8-hour period of inactivity, the remote control will automatically enter Public Mode.

After replacement of its battery, the remote control will automatically enter Public Mode.

Private Mode

The remote control sends signals that can only be received by the designated laser unit.

To activate Private Mode:

Press and hold the remote control scan mode button

(R)(closed padlock symbol beside the button) and at the same time, press and hold the scan mode button

(F)on the laser unit control panel (closed padlock symbol).

After 4 seconds, both the remote control and the laser unit will enter Private Mode. As confirmation, the laser unit will beep and the laser unit control panel LED (L) (next to the closed padlock symbol) and the remote control LED (T) (next to the closed padlock symbol) will flash.

Height of Instrument Alert

The DW079 has a built-in alarm feature that alerts the operator if the unit is disturbed after the unit has self-leveled. The laser unit will stop rotating, the control panel LED indicator lights will flash and the beeper will sound.

English

Image 15
Contents DW079 Rotary Laser Laser rotatif Láser rotativo Page Safety Instructions for Lasers Laser Information Read ALL Instructions Important Safety Instructions for All Battery PacksImportant Safety Instructions for All Battery Chargers Specific Safety Instructions for Lithium ION LI-IONRbrc Seal Do not operate charger with damaged cord or plug Wire Size AWGChargers Using Automatic Tune-Up ModeCharging Procedure Indicator Light OperationLeaving the Battery Pack in the Charger Charge IndicatorsHOT/COLD Pack Delay Problem Power LineLaser Maintenance Storage RecommendationsFor Future USE Laser Operation Installing and Removing Battery Pack Fig Laser Control PanelLaser Control Panel Buttons Using Scan Mode Self-Leveling Horizontal ModeSelf-Leveling Vertical Mode Manual ModeUsing the Wireless Remote Control Fig Setting the Amount of Slope Using Manual Slope ModeEntering and exiting Manual Slope Mode Setting the Slope DirectionHeight of Instrument Alert Remote Control SPEED/ROTATION ButtonRemote Control Scan Mode Button Remote Control Public and Private ModeManual Head Rotation Laser TroubleshootingUsing the Laser on a Tripod Using the Laser on a Floor FigTarget Card Laser AccessoriesLaser Enhancement Glasses Digital Laser Detector DW0772 FigDetector Operation Fig Batteries FIGDetector Controls FIG Mounting on a Grade ROD FIG Detector Cleaning and StorageDetector Service Detector TroubleshootingDetector does not Respond to a Stationary Laser Beam Using the Laser with a Wall MountConstruction Grade Rod DETECTOR’S Speaker Makes no SoundMark Laser Maintenance FIGLevel Calibration Check X-AXIS Field Calibration CheckRepairs Three Year Limited WarrantyEnglish Consignes de sécurité pour les lasers Conserver CES DirectivesInformations relatives au laser Caractéristiques Techniques Lire Toutes LES DirectivesFrançais Le sceau Srprctm Calibre AWG Fonctionnement des voyants Utilisation du Mode Tune-UpTMautomatiqueChargeurs Procédure de chargeProblèmes Avec LE Secteur Voyants de chargeRemarques importantes concernant le chargement Fonction DE Suspension DU BLOC-PILES CHAUD/FROIDRecommandations de rangement Retrait DU BLOC-PILES Installation et retrait du bloc-piles figInstallation DU BLOC-PILES Panneau de contrôle du laserBoutons du panneau de contrôle du laser En Mode d’auto-nivelage horizontalEn Mode d’auto-nivelage vertical En Mode manuelMode privé Utilisation du Mode de balayageMode public Pour activer le Mode publicUtilisation du Mode manuel d’inclinaison Utilisation de la Télécommande Sans fil figMode ignorer télécommande Pour activer le Mode ignorer télécommandeTélécommande Boutons Flèche Paramétrage de la direction d’inclinaisonParamétrage du taux d’inclinaison Télécommande Bouton VITESSE/ROTATION Télécommande Bouton Mode DE BalayageTélécommande Mode Public ET Privé Utilisation du laser sur le sol fig Signal de changement de hauteur de l’appareilLE Laser ET LA Télécommande NE Sont PAS Synchronisés Guide de dépannage du laserLunettes de visualisation laser Accessoires laserRotation manuelle de la tête Carte de détection de faisceauPiles FIG Commandes DU Capteur FIGFonctionnement du capteur fig Installation SUR UNE Tige Graduée FIGTige graduée de construction Entretien et rangement du capteurRéparation du capteur Guide de dépannage du capteurSS MM Utilisation du laser avec un montage mural figMaintenance DU Laser Vérification du calibrage figVérification DE Calibrage AXE DES Vérification DE L’APLOMB Vérification DE Calibrage AXE DES YGarantie DE Remboursement DE 90 Jours RéparationsGarantie limitée de trois ans Contrat D’ENTRETIEN Gratuit D’UN ANInstrucciones de seguridad para láseres Guarde Estas InstruccionesInformación sobre el láser Especificaciones LEA Todas LAS InstruccionesEspañol El sello Rbrctm Tamaño de conductor AWG Operación de la luz indicadora Indicadores de carga Utilización de la modalidad Tune-UpTMautomáticaCargadores Procedimiento de cargaPermanencia DE LA Unidad DE Batería EN EL Cargador Línea DE Alimentación ProblemáticaNotas importantes sobre la carga Retardo POR Unidad CALIENTE/FRÍARecomendaciones de almacenamiento Cómo Instalar LA Unidad DE Batería Panel de control del láserCómo instalar y retirar la unidad de batería Fig Cómo Retirar LA Unidad DE BateríaEn la modalidad manual Botones del panel de control del láserEn la modalidad de autonivelado horizontal En la modalidad de autonivelado verticalModalidad privada Modalidades PÚBLICA, Privada Y SIN RemotoModalidad pública Para activar la modalidad públicaUso de la modalidad de inclinación manual Uso del control remoto inalámbricoModalidad sin control remoto Para activar la modalidad sin control remotoPara configurar la dirección de inclinación Configuración del grado de inclinaciónControl Remoto Botones DE Flecha Control Remoto Botón DE VELOCIDAD/ROTACIÓN Control Remoto Botón DE Modalidad DE EscánerControl Remoto Modalidad Pública Y Privada Uso del láser con un trípode Resolución de problemas con el láserPara Reconfigurar LA Unidad Láser Para USO Continuo Alerta por elevación del instrumentoGafas láser Uso del láser directamente en el piso FigRotación manual del cabezal Accesorios para el láserDetector digital de láser DW0772 Fig Pilas FIGControles DEL Detector FIG Montaje Sobre UNA Vara Graduada FIG Operación del detector FigResolución de problemas del detector Limpieza y almacenamiento del detectorServicio para el detector Vara graduada de construcción Uso del láser con un soporte de paredEL Detector Emite UN Tono Pero LA Pantalla LCD no Funciona Mantenimiento DEL Láser Control DE Calibrado DEL Nivel EJE Control de calibrado en el campoControl DE Error DE LA Plomada FIG ReparacionesControl DE Calibrado DEL Nivel EJE Y Servicio Gratuito DE 1 AÑO Póliza de GarantíaGarantía limitada de tres años ExcepcionesDW079 18,0 V DC Garantía DE Reembolso DE Dinero DE 90 DíasPage Dewalt Battery and Charger Systems