Graco Inc 313314B, 300E Electrical Troubleshooting, If check is OK, go to next check

Page 34

Repair / Réparation / Reparación

Electrical Troubleshooting

 

WHAT TO CHECK

WHAT TO DO

TYPE OF PROBLEM

If check is OK, go to next check

When check is not OK, refer to this column

 

 

 

 

 

 

Sprayer does not run at all

See flow chart, page 40.

 

 

 

 

Digital display is blank

 

 

 

 

 

Control board status light never

 

 

lights

 

 

 

 

 

Sprayer does not run at all

See flow chart, page 40.

 

 

 

 

Digital display shows dashes

 

 

and psi icon is not blinking

 

 

 

 

 

 

 

 

Control board status light blinks

WatchDog Activated

Reset Watchdog

once when switch is turned on

 

 

 

but then stays off

 

 

 

 

 

 

 

Sprayer does not run at all

Check transducer or transducer

1.

Make sure there is no pressure in the system (see

 

connections

 

Pressure Relief, page 15). Check fluid path for

Digital display shows E=02

 

 

 

clogs, such as clogged filter.

 

 

 

 

 

2.

Use airless paint spray hose with no metal braid

 

 

 

1/4 in. x 50 ft minimum. Smaller hose or metal braid

 

 

 

hose may result in high-pressure spikes.

 

 

 

 

Control board status light blinks

 

3.

Set sprayer to OFF and disconnect power to sprayer.

2 times repeatedly

 

 

 

 

 

 

4.

Check transducer and connections to control board.

 

 

5.

Disconnect transducer from control board socket.

 

 

 

Check that transducer and control board contacts

 

 

 

are clean and secure.

 

 

6.

Reconnect transducer to control board socket.

 

 

 

Connect power, set sprayer ON and control knob

 

 

 

1/2 turn clockwise. If sprayer does not run properly,

 

 

 

set sprayer to OFF and go to next step.

 

 

7.

Install new transducer. Connect power, set sprayer

 

 

 

ON and control knob 1/2 turn clockwise. Replace

 

 

 

control board if sprayer does not run properly.

 

 

 

 

34

313314B

Image 34
Contents 313314B Consignes DE Sécurité ImportantesGrounding Instructions GroundingFire and Explosion Hazard Skin Injection HazardPressurized Aluminum Parts Hazard Equipment Misuse HazardElectric Shock Hazard Moving Parts HazardInstructions de mise à la terre Mise en gardeMise a LA Terre Mise EN Garde Risques DUS AUX Pièces EN Aluminium Sous Pression Équipement DE Protection PersonnelleAdvertencias Instrucciones de conexión a tierraPeligro DE Incendios Y Explosiones De los vapores explosivosPeligros Debidos a LA Utilización Incorrecta DEL Equipo Lesiones graves y daños materialesFiltre Filtro English Français EspañolFluid Outlet Español EnglishFrançais Ou de court-circuit Haya un cortocircuitoSpécification électrique Power RequirementsExtension Cords RallongesBidones PailsTierra. Después dispare la pistola Décompression Pressure ReliefDescompresión Setup / Installation / Puesta en marcha Al pulverizador. Apriete firmementeRevise el elemento filtrante de entrada Turn prime valve down ’huile et l’huile d’entreposageTurn power on La gâchette du pistoletColoque el tubo de aspiración en la lata de pintura Ti13023a Never point gun at your hand or into a rag SprayClear Clog PulvériserPosition Perform Pressure Relief’écoule Secondes pour nettoyer le tuyau de vidange 15 to 30 seconds to drain fluidTurn prime valve down Drain position. Unplug sprayer Ouvrir la vanne d’amorçage. Débrancher Le pulvérisateurTi2895a Ti13029a What to Check What to do Type of Problem Repair / Réparation / ReparaciónSprayer. Use 3/8 in. hose for optimum With heavy materialsHose significantly reduces performance Performance 50 ft minimumConsulter cette colonne Quoi Vérifier Quoi FaireType DE Problème Aller à la vérification suivanteAller à la vérification suivante Consulter cette colonne De las siguientes causas Consulte esta columna ProblemaCausa Medida a Tomar Compruebe si existe alguna Cuando detecte la causaLimpie la boquilla consulte el manual En la tuerca prensaestopas Está flojaDel protector de la boquilla Electrical ÉlectricitéAvertissement Problemas eléctricosInstrucciones para observar los códigos de error Alivie la presión, páginaElectrical Troubleshooting If check is OK, go to next checkSprayer does not run at all Check transducer or transducer Detecting a pressure signalContacts are clean and secure Connections control board is not Digital display shows E=03Step Check Motor Thermal Switch Unplug thermal Resistance TableSecure Reconnect thermal device connector to controlBoard socket. Connect power, turn sprayer on Is not correct, replace motorElectric Motor Will Not Shut Off Troubleshooting ProcedureYES Defective thermal device Connect a test Motor Will Not RunSee . Do You have over AC volts? ReplaceControl Board With GFI Filter Coil Si tout est normal après Dépannage électriqueSuivante Consulter cette colonne Quoi Vérifier Étape Faire l’Essai de rotation essai au gros connecteurTableau des résistances Faire l’Essai de court-circuitage de champ essai auAucun fonctionnement Laisser le pulvérisateur se refroidir Procédure de dépannage Remplacer le bloc de commandeArrêt impossible du moteur NONRemplacer ’interrupteur Si le moteur est chaud, laisser Refus du moteur de tournerOUI NON Remplacer leFil blanc du cordon d’alimentation Solución de problemas eléctricos Consulte esta columnaCausa Medida a Tomar Paso Realice una prueba de rotación Someta a una pruebaTabla de resistencia Realice una prueba breve de campo Someta a unaInspeccione el interruptor térmico del motor Procedimiento de solución de problemas El motor elétrico no se apagaCambie el Interruptor de alimentación El motor no funcionaRepare Motor? Cambie el Tablero deNegro al tablero Negro desde el cable eléctrico Carénage avant Removal / Retrait / ExtracciónFront Shroud Recubrimiento delanteroCarénage avant Carénage arrière Installation / Installation / InstalaciónFront Shroud Rear Shroud Recubrimiento delantero Recubrimiento traseroDiagram, Quite el tornillo de la puesta a tierra 26 y el cable ConnectorsDisconnect transducer 86 and remove wiring grommet Quite el ojal y desconecteTi13083a Ti13083a Ti13084a Ti12999a Ti13087a Replace shroud 58 and tighten screws 13 Installer le fil de terre et serrer la visRemettre en place le carénage 58 et serrer les vis 13 et 115 Quite la cubierta trasera páginaRotate new potentiometer Ti13074a Ti12999a 86G Replace transducer wiring Use wrench to tighten Wiring protector Grommet 86GBrancher le fil du transducteur Remettre en place Remettre en placeRemettre en place Les carénages avant et arrière, voir Avis MotorReplace pump, Lift retaining spring and replace pump pin Replace pump rod covers Replace front shroud Tighten screws Replace rear shroud,Flush pump Remove screws 31 Power cordPush up retaining spring Push pump pin 44 out Débrancher le flexible Installation / Installation / Instalación De bombeo en o dentro de la varilla de unión Étendre la tige de piston de la pompe sur 1,5 poExtienda la varilla del pistón 1.5 in. Aplique grasa De la bomba se engancheVisser l’écrou de blocage 102 Nm± 5 lb-pi 102 Nm Arrière, voir Rodamiento Del recubrimiento Página Replace rear shroud mounting bracket 49. Replace shroud,Vuelva a colocar el Alojamiento del Colocar elParts / Pièces / Piezas Part Description Qty Ref. Part DescriptionQty Screw Parts Filter / Pièces Filtre / Piezas Filtro Wiring Diagram Diagramme de câblage Motor Diagrama de cableadoInterruptor Thermal Térmico Switch Potenciómetro TransductorTechnical Data Fiche techniqueDatos técnicos International Offices Belgium, Korea, China, Japan Warranty / Garantie / GarantíaGraco Headquarters Minneapolis 11/2008