I m p o r t a n t

S a f e g u a r d s

9.Do not use outdoors. This product is for household use only.

10.Do not use in an oxygen enriched environment.

11.Connect this product (for grounded models) to a properly-grounded outlet only. See Grounding Instructions.

12.Do not use this product with a DC to AC converter, or with any AC voltage and/or frequency other than specified.

13.Do not operate unit in a backpack or carrying bag.

14.Care should be taken when this product is used in the vicinity of other electronic equipment concerning the possible interference between them. They may need to be moved apart.

NOTE– This unit employs a temperature and/or current limiting device that will shut off the entire product should a malfunction occur or in the event of product misuse, abuse, or abnormal operation. Contact your qualified Sunrise provider for a replace- ment unit if necessary.

5650–The unit will restart when the motor cools to an acceptable level. 4650/3655–Contact your qualified Sunrise provider for a replacement.

This appliance has a polarized plug (one blade is wider than the other). As a safety fea- ture, this plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If repair or replacement of the cord or plug is neces- sary, contact your qualified Sunrise provider.

NOTE– The exterior surfaces of the unit and the air outlet connector may become slightly warm to the touch during use. Warm air can also be felt exiting the vents on the sides of the case of the unit. This is normal.

MODEL 5650H & 4650D GROUNDING INSTRUCTIONS

This product should be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.

DANGER

Improper use of the grounding plug can result in the risk of electric shock.

If repair or replacement of the cord or plug is necessary, contact your qualified Sunrise provider.

1.This unit is for use on a nominal 115V circuit and has a grounding plug. A temporary adapter, which looks like the adapter illustrated in Figures B and C, may be used to connect this plug to a 2-pole receptacle (as shown in Figure B) if a properly grounded outlet is not available. The temporary adapter should be used only until a qualified electrician can install a properly grounded outlet (Figure A). The grounding ear, lug, or wire extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by the metal screw.

A-655

Image 4
Contents DeVilbiss Compressor/Nebulizer Instruction Guide English EspañolFrançais B l e N t e n t sP o r t a n t F e g u a r d s To reduce the risk of electrocutionModel 5650H & 4650D Grounding Instructions P o r t a n t F e g u a r d s T r o d u c t i o n IntroductionStatement of Intended Use P o r t a n t R t s U r M p r e s s o r Figure a On backP o r t a n t R t s U r B u l i z e r HOW to Operate Your CompressorModels 4650 & 5650 Steps 1-3 and Steps E r a t e U r M p r e s s o r Models 3655 Steps 1-3 and StepsNebulizer Cleaning E a n i n gCompressor Cleaning Disinfect DailyMaintenance Filter ChangeL t e r A n g e I n t e n a n c e Models 4650Specifications Specification sElectrical OperatingManufacturers Note FIVE-YEAR Limited Warranty on Compressor PartsR r a n t y E c a u c i o n e s P o r t a n t e s LEA Todas LAS Instrucciones Antes DE UsarloPara reducir el riesgo de electrocutación Peligro Introducción Enunciado de uso idóneoR t e s P o r t a n t e s Figuras a y BPartes Importantes DE SU Nebulizador Desechable Partes Importantes DE SU Nebulizador ReutilizableCómo Operar SU Compresor A r t e s P o r t a n t e sModelos 3655 Pasos 1-3 y pasos M o E r a r M p r e s o rTodos Modelos Pasos Limpieza DEL Nebulizador M p i e z aPara evitar un posible riesgo de infección debido a Un medicamento contaminado, se recomiendaDiariamente Limpieza DEL CompresorNo lo sumerja en agua, ya que dañaría el compresor Cambio DE Filtro MantenimientoM b i o L t r o N t e n i m i e n t o Modelos 4650 yEspecificaciones P e c i f i c a c i o n e sNota DEL Fabricante R a n t í aS e s R d e P o r t a n t e s Lire Toutes LES Instructions Avant L’UTILISATIONPour réduire les risques d’électrocution S e s R d e P o r t a n t e s Garder CES Instructions Déclaration d’utilisation envisagéeI è c e s P o r t a n t e s Figures a et BPièces Importantes DE Votre Nébuliseur Jetable Pièces Importantes DE Votre Nébuliseur RéutilisableÈ c e s P o r t a n t e s Modèles 4650 et 5650 étapes 1-3 et étapesM m e n t I r e N c t i o n n e r M p r e s s e u r Nettoyage DU Nébuliseur T t o y a g eNettoyage DU Compresseur Désinfecter chaque joursChangement DU Filtre EntretienA n g e m e n t L t r e T r e t i e n Modèles 4650 etSpécifications É c i f i c a t i o n sFlux d’air libre du compresseur- Séries 3655 et Amplitude de températuresR a n t i e Classes d’équipement de 3655D et 3655TSunrise Medical Sunrise Medical Canada, Inc