Controls Configuration & Adjustments...
5.Defrost Sensor Calibration...continued:
H.Once the correct temperature value has been selected not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the [POOL/SPA] key will also save the selection and step to the next menu parameter [dBS], (Dead Band for Spa).
6.Spa Dead Band Differential [dBS]:
The dead band differential determines the number of degrees that the water temperature must fall below the set point before the thermostat closes (Heat Mode). In the cooling mode the dead band differential determines the number of degrees that the water temperature must rise above the set point before the thermostat closes again. When in the
A.Follow the steps 1a. through 1d. above to enter the service menu. Once [dEL] is displayed, press the [POOL/SPA] key until the display shows [dBS] (Spa Dead Band Differential).
B.With the service menu parameter [dBS] displayed, pressing either the [UP] or [DOWN] arrow keys once will display the current setting. Using the [UP] or [DOWN] arrows keys will increase or decrease the value respectively. The differential is adjustable in 1o increments from 1 to
C.Once the desired dead band value has been selected not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu parameter [dBP], (Dead Band Pool).
7.Pool Dead Band Differential [dBP]:
The dead band differential determines the number of degrees that the water temperature must fall below the set point before the thermostat closes (Heat Mode). In the cooling mode the dead band differential determines the number of degrees that the water temperature must rise above the set point before the thermostat closes again. When in the
A.Follow the steps 1a. through 1d. above to enter the service menu. Once [dEL] is displayed, press the [POOL/SPA] key until the display shows [dBP] (Pool Dead Band Differential).
B.With the service menu parameter [dBP] displayed, pressing either the [UP] or [DOWN] arrow keys once will display the current setting. Using the [UP] or [DOWN] arrows keys will increase or decrease the value respectively. The differential is adjustable in 1o increments from 1 to 5 degrees.
(Continued on Next Page)