Schumacher PSW-70300A Calculating Charge Time, Specific Gravity Percent of Charge Needed

Page 10

General Charging Notes

Fan: The charger is designed to control its cooling fan for efficient operation. Consequentially, it is normal for the fan to start and stop when maintaining a fully charged battery. Keep the area near the charger clear of obstructions to allow the fan to operate efficiently.

Voltage: The voltage displayed during charging is the charging voltage and is usually higher than the battery’s resting voltage.

13. CALCULATING CHARGE TIME

The Hydrometer or Electronic Method

To find the time needed to fully charge your battery, determine the battery’s charge level with a hydrometer or electronic Percent-of-Charge Tester. The following table will help you convert hydrometer readings to percent of charge values.

SPECIFIC GRAVITY

PERCENT OF CHARGE

PERCENT OF CHARGE

NEEDED

 

 

1.265

100%

0%

1.225

75%

25%

1.155

25%

75%

1.120

0%

100%

When you know the percent of charge and the Amp Hour (AH) rating of your battery, you can calculate the approximate time needed to bring your battery to a full charge.

To convert Reserve Capacity to Amp Hours, divide Reserve Capacity by 2, and add 16:

Example:

Amp Hour Rating = Reserve Capacity + 16

2

NOTE: The Reserve Capacity can be obtained from the battery specification sheet or the owner’s manual.

To calculate the time needed for a charge:

1.Find the percent of charge needed. (A battery at 50 percent charge that will be charged to 100 percent needs another 50 percent (.50)).

2.Multiply the Amp Hour Rating by the charge needed (.50) and divide by the charge rate.

3.Multiply the results by 1.25 and you will have the total time needed, in hours, to bring the battery to full charge.

4.Add an additional hour for a deep-cycle battery.

Example:

Amp Hour Rating x % of charge needed x 1.25 = hours of charge

Charger Setting

100 (AH Rating) x .50 (charge needed) x 1.25 = 3.125 hours 20 (Charger Setting)

100 x .50 x 1.25 = 3.125

20

You would need to charge your 100-Ampere Hour Battery for a little more than 3 hours at the 20-Amp charge rate using the above example.

• 10 •

Image 10
Contents PSW-70300A Risk of Electric Shock or Fire Personal Precautions Risk of Explosive Gases DC Connection Precautions Features Assembly InstructionsParts Tools Needed Operating Instructions Control Panel TimerAutomatic Temperature Compensation Thermal RunawayDesulfation Mode Automatic Charging ModeManual Charging Mode Maintain Mode Float-Mode MonitoringUsing the Battery Voltage Tester Overview Using the Alternator Performance Tester OverviewCalculating Charge Time Specific Gravity Percent of Charge NeededMaintenance Instructions Chart MethodBattery SIZE/RATING Charge RATE/CHARGING Time Moving and Storage InstructionsTroubleshooting Problem Possible Cause REASON/SOLUTION Problem Possible Cause REASON/SOLUTION Before Returning for RepairsLimited Warranty Warranty not valid in MexicoBusiness Center Drive Mail this card toMount Prospect, IL Inscription AU Programme DE Garantie Limitée DE 3 ANS EL Riesgo DE Descarga Eléctrica O Incendio Riesgo DE Gases Explosivos Precauciones Personales Riesgo DE Gases ExplosivosPrecauciones DE Conexión EN CC Conexiones a tierra y energía de CA Instrucciones DE Montaje CaracterísticasArtí Piezas Herramientas Culo Necesarias Panel DE Control Temporizador Compensación de Temperatura Automática Interruptor de selección de índice de cargaInstrucciones DE Operación Escape termalCarga anulada Modo de carga automáticaModo de Carga Manual Modo de desulfataciónUtilizar la función de encendido de motor Utilizar el probador de tensión de batería Visión generalEl método hidrómetro o electrónico Notas generales sobre la carga13. Cálculo DE Tiempo DE Carga EjemploInstrucciones DE Mantenimiento El método del gráficoTAMAÑO/ÍNDICE DE LA Batería ÍNDICE/TIEMPO DE Carga Instrucciones para el manejo y almacenamientoLocalización Y Solución DE Problemas Posible Causa Problema Posible Causa Solución Antes DE Devolver a Reparaciones ¡NO LO Devuelva este producto a LA Tienda Risque DE Choc Électrique OU D’INCENDIE Risque DE GAZ Explosifs Précautions Personnelles Risque DE GAZ ExplosifsPrécautions SUR LA Connexion C.C Mise à la terre et cordon d’énergie CA Directives DE Montage CaractéristiquesPièces Outils Nécessaires Page Panneau DE Contrôle Minuterie Commutateur-sélecteur du taux de chargeConsignes D’UTILISATION Mode Entretien Contrôlant le Mode de monitor Utilisation du dispositif Aide-DémarrageTester la performance de l’alternateur Vue d’ensemble Pourcentage Densité DE Chargement Nécessaire Calcul DU Temps DE ChargementLe densimètre ou la méthode électronique ExempleConsignes D’ENTRETIEN Instructions de transport et stockageTableau DE Dépannage Problème Cause Possible RAISON/SOLUTION Problème Cause Possible RAISON/SOLUTION Avant DE L’ENVOYER Pour Réparation Garantie Limitée Garantie n’est pas valide au Mexique