Schumacher PSW-70300A Control Panel Timer, Operating Instructions, Thermal Runaway, Charging

Page 7

11.CONTROL PANEL Timer

Timer Setting: The timer allows you to set a specified time for charging. After the timer expires, the charger stops charging your battery. The main function of the timer is to prevent over charging while allowing a battery time to obtain a satisfactory charge. To properly set the timer, you must know the size of the battery in ampere hours or reserve capacity in minutes and the state of charge. It is important that you determine the appropriate state of charge of your battery as specified in Section 13 and set the timer accordingly.

Hold: This position defeats the timer function, allowing for continuous operation.

Automatic Modes: Put the timer in the HOLD position when using the battery charger in one of the Automatic Modes (4, 20 or 70 amp), otherwise the timer will stop the charging process when the time expires regardless of whether

it is complete or not. The CHARGED (green) LED will light when charging is complete and the charger goes into Maintain Mode. The charger will not shut off.

Manual Modes: Put the timer in the HOLD position when using the battery charger in the Manual Mode (40 amp) and when you want to charge more than 2¼ hours. Be sure to monitor the charging progress and stop it when the battery is charged. Not doing so may cause damage to your battery or may cause other personal property damage or personal injury.

Ammeter

The Ammeter indicates the amount of current, measured in amps, that is being drawn by the battery. As a battery takes on a charge, it draws less current from the charger. Correspondingly, the meter will show less current being drawn by the battery. When the current stops decreasing, the battery is charged. The 4 amp charge rate may indicate some activity on the meter, although the meter does not have the resolution to display this low rate.

Voltmeter

The voltmeter indicates the voltage at the battery terminals. The charger need not be plugged into an AC outlet. The timer should be in the OFF position. Then connect the charger following the instructions in Sections 6 and 7. Observe the meter indication.

Keep in mind that this reading is only a battery voltage reading, a false surface charge may mislead you. We suggest that you turn on the headlights for a couple of minutes before you read the meter. Read it a couple of minutes after you have shut the headlights off. If the reading is less than 10.5-volts, the battery may be bad or the connection at the charger may be poor. If the reading is 10.5-volts to 12.8-volts, the battery is low – recharge it. If the reading is above 12.8-volts, the battery is charged.

Charge Rate Selector Switch

Use the Charge Rate selector switch to select the charge rate or engine starting setting you require.

4A Slow Charge Rate – Intended for charging small batteries such as those commonly used in garden tractors, snow mobiles and motorcycles.

20A and 40A Fast and 70A Rapid Charge Rate – Use for charging automotive, marine and deep-cycle batteries. Not intended for industrial applications.

300A Engine Start – Provides 300 amps for cranking an engine with a weak or run down battery. Always use in combination with a battery.

12.OPERATING INSTRUCTIONS

Automatic Temperature Compensation

The charger adjusts the maximum charge voltage and maximum maintain voltage based on the ambient air temperature. This permits optimum charging and safety.

Thermal Runaway

The charger automatically reduces the current if it detects the battery may be getting too hot. This is a safety precaution.

Charging

1.Ensure that all of the charger components are in place and in good working condition, including the plastic boots on the battery clips. Make sure the electrolyte

(battery liquid) in each cell is at the correct level.

2.Set the charge rate switch and the timer to the OFF position.

• 7 •

Image 7
Contents PSW-70300A Risk of Electric Shock or Fire Personal Precautions Risk of Explosive Gases DC Connection Precautions Assembly Instructions FeaturesParts Tools Needed Thermal Runaway Control Panel TimerAutomatic Temperature Compensation Operating InstructionsMaintain Mode Float-Mode Monitoring Automatic Charging ModeManual Charging Mode Desulfation ModeUsing the Alternator Performance Tester Overview Using the Battery Voltage Tester OverviewSpecific Gravity Percent of Charge Needed Calculating Charge TimeMoving and Storage Instructions Chart MethodBattery SIZE/RATING Charge RATE/CHARGING Time Maintenance InstructionsTroubleshooting Problem Possible Cause REASON/SOLUTION Before Returning for Repairs Problem Possible Cause REASON/SOLUTIONWarranty not valid in Mexico Limited WarrantyBusiness Center Drive Mail this card toMount Prospect, IL Inscription AU Programme DE Garantie Limitée DE 3 ANS EL Riesgo DE Descarga Eléctrica O Incendio Precauciones Personales Riesgo DE Gases Explosivos Riesgo DE Gases ExplosivosPrecauciones DE Conexión EN CC Conexiones a tierra y energía de CA Instrucciones DE Montaje CaracterísticasArtí Piezas Herramientas Culo Necesarias Panel DE Control Temporizador Escape termal Interruptor de selección de índice de cargaInstrucciones DE Operación Compensación de Temperatura AutomáticaModo de desulfatación Modo de carga automáticaModo de Carga Manual Carga anuladaUtilizar el probador de tensión de batería Visión general Utilizar la función de encendido de motorEjemplo Notas generales sobre la carga13. Cálculo DE Tiempo DE Carga El método hidrómetro o electrónicoInstrucciones para el manejo y almacenamiento El método del gráficoTAMAÑO/ÍNDICE DE LA Batería ÍNDICE/TIEMPO DE Carga Instrucciones DE MantenimientoLocalización Y Solución DE Problemas Posible Causa Problema Posible Causa Solución Antes DE Devolver a Reparaciones ¡NO LO Devuelva este producto a LA Tienda Risque DE Choc Électrique OU D’INCENDIE Précautions Personnelles Risque DE GAZ Explosifs Risque DE GAZ ExplosifsPrécautions SUR LA Connexion C.C Mise à la terre et cordon d’énergie CA Directives DE Montage CaractéristiquesPièces Outils Nécessaires Page Commutateur-sélecteur du taux de charge Panneau DE Contrôle MinuterieConsignes D’UTILISATION Utilisation du dispositif Aide-Démarrage Mode Entretien Contrôlant le Mode de monitorTester la performance de l’alternateur Vue d’ensemble Exemple Calcul DU Temps DE ChargementLe densimètre ou la méthode électronique Pourcentage Densité DE Chargement NécessaireInstructions de transport et stockage Consignes D’ENTRETIENTableau DE Dépannage Problème Cause Possible RAISON/SOLUTION Problème Cause Possible RAISON/SOLUTION Avant DE L’ENVOYER Pour Réparation Garantie n’est pas valide au Mexique Garantie Limitée