DSCover Satellite Products SCW904x manual Advanced Programming

Page 18

Self Contained Wireless Alarm System v1.0

Section 6: Advanced Programming

This section provides the information necessary to program all required features for a basic system as well as common applications.

6.1 How to Program:

DSC recommends filling in the Programming Worksheet with the required programming information before programming the system. This will reduce the time required to program and will help eliminate errors.

To enter Installer Programming press [ ][8][Installer Code]. The LCD keypad will display ‘Enter Section’. An error tone indicates the installer code entered is incorrect. Press [#] to clear any key presses and try again.

The default Installer Code is [5555] .

The Armed and Ready lights indicate programming status:

Armed Light ON

Panel waiting for 3-digit section number

Ready Light ON

Panel waiting for data to be entered

Ready Light FLASHING

Panel waiting for HEX data to be entered

You cannot enter installer programming while the system is armed or in alarm.

6.2 Programming Toggle Options:

Enter the 3-digit programming section number

Option ON

Option OFF

 

 

# Displayed

Dash [-]Displayed

 

 

The Armed light will turn OFF and the Ready light will turn ON.

The keypad will display which toggle options are ON or OFF according to the chart.

To toggle an option ON or OFF, press the corresponding number on the keypad. The display will change accordingly.

When all the toggle options are configured correctly, press the [#] key to exit the program section.

The Ready light will turn OFF, the Armed light will turn ON and the LCD will display “Enter Section”.

6.3 Programming Decimal and Hexadecimal (HEX) Data:

Enter the 3-digit programming section number.

The Armed light will turn OFF and The Ready light will turn ON.

Enter the data written in the boxes.

For sections that require multiple 2 or 3 digit numbers, the keypad will double-beep after each 2 or 3 digit entry and move to the next item in the list. After the last digit in the section is entered, the keypad will beep rapidly 5 times and exit the program section. The Ready light will turn OFF, the Armed light will turn ON and the LCD will display “Enter Section”.

For sections that do not require data for every box (such as phone numbers) press the [#] key to exit the program section after entering all the required data. The Ready light will turn OFF, the Armed light will turn ON and the LCD will display “Enter Section”.

At any time the [#] can be pressed to exit any program section. All changes made up to that point will be saved.

In addition to the standard digits 0-9, HEX digits and special dialer functions can also be programmed.

To enter a HEX digit, press the [ ] key to begin HEX programming. The Ready light will FLASH. Press the number corresponding to the HEX digit required. The Ready light will continue to FLASH. Press [ ] again to return to normal decimal program- ming. The Ready light will turn ON.

Value

Enter

 

 

 

Telephone Dialer

 

 

 

 

 

 

HEX [A]

Press

[

][1][

]

Not Supported

HEX [B]

Press

[

][2][

]

Simulated [ ] key

HEX [C]

Press

[

][3][

]

Simulated [#] key

HEX [D]

Press

[

][4][

]

Dial tone search

HEX [E]

Press

[

][5][

]

Two second pause

HEX [F]

Press

[

][6][

]

Not Supported

 

 

 

 

 

 

6.4 How to Exit Installer Programming:

To exit installer programming, press the [#] key when the panel is waiting for a 3-digit section number (the Armed light is ON). The LCD will display the user menu.

6.5 Viewing Programming

The keypad will immediately display all the information programmed when a programming section is entered. Use the arrow keys (< >) to scroll through the data being displayed. Scroll past the end of the data displayed, or press the [#] key to exit the section.

14WWW.DIYALARMFORUM.COM

Image 18
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Installation & Wiring Technical SummaryInstallation Ensure connector key is oriented correctlyWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Activate Wireless Device Wireless Device EnrollmentEnter Wireless Enrollment Mode Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Template Programming Zone Definitions Options 1Digit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out DLS Programming New Installations Refer to .1 Installation onExisting Installations Refer to .1 Installation on Local Programming with PC-LinkOperation Trouble Display Alarm Memory DisplayDoor Chime Enable/Disable Program User CodesAdditional Keypad Functions 7x Command Outputs 1&2Installer Programming 9User Code No-Entry ArmingAdvanced Programming Programming Work Sheets Index to Programming Work Sheets and DescriptionsFunction Key Options Programming WorksheetsFunction Key Programming Zone Definitions009 I/O Programming Installer’s Code Master CodeSystem Times Keypad Lockout OptionsFourth System Options Second System OptionsThird System Options Tenth System OptionsZone Loop Response Options Zone Attributes Options 10-13 are reserved for Future UseNo Activity Arming Pre-alert Timer PGM Output TimerCross Zone/Police Code Timer No Activity Arming TimerMiscellaneous Alarm Reporting Codes Alarm Reporting Codes, ZonesAlarm Restoral Reporting Codes, Zones Priority Alarm and Restoral Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions Communication Variables System Maintenance Communicator Call DirectionsSystem Test Transmissions Communicator Call Directions Test Transmission Time of DaySecond Communicator Options Third Communicator OptionsDownloading Options PGM Output Attributes Number of Rings To Answer OnInitiate PC-Link Downloading Attribute600 2-way Audio Control Options Applies to SCW9047 only Automatic Clock AdjustDelay Between Dialing Attempts First International OptionsWireless programming Wireless Zone Programming Wireless Supervisory WindowInstaller Lockout Disable General Wireless OptionsWireless Module Placement Test Installer Lockout Enable Restore Wireless Device Default ProgrammingLocal Keypad Programming Label Programming ZoneCommand Output #1 Label Fire Alarm LabelAlarm When Armed Event Message Command Output #2 LabelSecond Keypad Options Reset Programmable Labels to Factory DefaultsFirst Keypad Options Third Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions Master Code Installer CodeSystem Times O Programming Zones/PGMsFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank Daylight Saving Time Move Clock Ahead Zone Loop Response Options134 Zone Attributes Standard Time Set Clock BackNo Activity Arm Timer PGM Output TimerCross Zone/Police Code Timer Call Waiting Cancel StringCommunicator Variables Test Transmission TimeFirst Communicator Options Third Communicator Options OFF Closing Confirmation Disabled. The keypad does not beepSecond Communicator Options First Downloading OptionsPanel Identification Code Downloading Access CodeDownloading Computer Phone Number Number of Rings to Answer OnAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type First International Options Delay Between Dialing AttemptsWireless Programming Second International OptionsInstaller Lockout Disable Wireless Module Placement TestInstaller Lockout Enable Restore Wireless Device Default Programming069 Command Output Label Fire Alarm LabelsAlarm when Armed Event Message Keypad ProgrammingSecond Keypad Options OFF Power LED is disabled. Option 6 has no effectFirst Keypad Options Option Description Future UseProgrammed LCD Message Label ResetThird Keypad Options Programmed LCD Message DurationTesting & Troubleshooting Trouble 4 Failure to Communicate Trouble 8 Loss of Clock/DateAppendix a Reporting Code Formats Contact IDContact ID Zone Alarm/Restoral Event Codes SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Communicator Format Options Pager Residential DialAppendix C Regulatory Approvals Information North AmericaSIA False Alarm Reduction Installations EuropeNew Zealand Appendix D SIA False Alarm Reduction Exit TimeAppendix E 2-Way Audio Verification SCW9047 only Format Reporting Code/EventHang-up Auto-detection Key Command DescriptionVOX Support Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement