Page 40

Self Contained Wireless Alarm System v1.0

[8]ON: System Tamper Enabled. The panel will monitor the physical tamper switch, if the system is taken off the wall, or the front housing is removed, a System Tamper Alarm will be generated.

OFF: System Tamper Disabled: The panel will not monitor the physical tamper switch.

Section [016] Fourth System Options

Option Description

[1]ON: Cross Zoning Enabled. The panel will use the Cross Zone Attribute for Burglary Verification.

OFF: Police Code Enabled. The panel will use the Police Code feature for Burglary Verification.

[2]ON: Exit Delay Restart Enabled. A One-time Exit Delay Restart on Delay zone re-entry is enabled. If a Delay zone (Delay 1 or 2 only) is violated and restored once during the Exit Delay, it is considered an exit. If a delay zone is violated again it is considered a re- entry. This option will restart the exit delay. Further violations and restores of delay zones will not restart the exit delay.

OFF: Exit Delay Restart Enabled. One Time Exit Delay Restart on Delay zone re-entry is disabled. Delay zone violations and restores will not restart the exit delay. (ON for SIA CP-01)

The exit delay can only be restarted once. This includes restarts from Away function keys. If the Exit Delay was silent, the addi- tional Exit time should remain silent and will be double the programmed Exit Time.

[3]ON: Blank Keypad when not Used. The keypad blanks (no indicator lights) if a key is not pressed for 30 seconds.

OFF: Keypad Always Active. The keypad does not blank.

[4]ON: Code Required to Remove Keypad Blanking. A valid user code must be entered to restore normal keypad operation.

OFF: No Code Required. Pressing any key will return the keypad to normal operation.

[5]ON: Keypad Backlighting Enabled. Backlighting is enabled for LCD and Keys.

OFF: Keypad Backlighting Disabled. Backlighting is disabled for LCD and Keys.

[6]ON: Identified WLS Keys Not Required for Disarming. The panel will accept the disarm keycode from an unidentified Wireless Key, allowing disarming with without an associated user code programmed.

OFF: Identified WLS Keys Required for Disarming. The panel will NOT accept the disarm keycode from an unidentified Wireless Key. An access code must be associated with a WLS KEY for proper operation.

[7]ON: Bypass Status Displayed While Armed. the keypad displays the “Warning Bypass Active” prompt if zones are bypassed while

the system is armed. OFF: Bypass Status Not Displayed While Armed. The “Warning Bypass Active” prompt is not displayed when the system is armed.

[8]ON: Daylight Saving Time Enabled. Enables the Daylight Saving automatic clock adjustment feature.

OFF: Daylight Saving Time Enabled. The system does not automatically adjust the clock for Daylight Saving.

Section [023] Tenth System Options

Option Description

[1]ON: [F] Key Beeps Only. The keypad [F] emergency key will only beep three times to acknowledge the button has been pressed.

The system will not activate the siren. OFF: [F] Key Beeps and Sounds Bell. The system will activate the siren and beep the keypad.

[2]Future Use

[3]ON: Test Transmission While Armed Only. The system will only transmit the Test Transmission reporting code if the system is

armed at the time the system is programmed to report the event. OFF: Test Transmission while Armed/Disarmed. The system will always report the Test Transmission reporting code at the programmed time.

[4]ON: Transmission Counter in Hours. The system changes the Test Transmission Reporting Cycle Time from Days to Hours. OFF: Transmission Counter in Days. The Test Transmission Reporting Cycle Time is in Days.

[5]ON: Switching From Away to Stay Disabled. The user can NOT switch from Away Arm mode to Stay Arm mode using the

function keys. OFF: Away to Stay Toggle Option Permitted. The user can switch arming modes.

[6]ON: New Alarms will not Disconnect 2-way Audio. The system will not disconnect a listen in/two-way session if an alarm occurs.

OFF: New Alarms Disconnects 2-way Audio. The system will disconnect. New events are transmitted after the session ends.

This option must be OFF for UL Listed Installations. Applies to SCW9047 only.

[7]ON: Trouble Beeps are Silent. The system does NOT activate the keypad buzzer for any trouble condition except fire.

OFF: Trouble Beeps Sound Every 10 Seconds. The system annunciates troubles via the keypad buzzer (2 beeps every 10 seconds).

[8]ON: Keyswitch Arms in Away Mode. Keyswitch zones on the system will always arm the system in Away.

OFF: Keyswitch Arms in Stay or Away Mode. When a keyswitch zone is used to arm the system, the final armed mode will depend on whether the user trips a delay zone during exit delay. If the user trips a delay zone, then the system will arm in Away mode, if not, then the system will arm in Stay mode. This is similar to arming the system at the keypad with an access code. The exit delay will be audible.

36WWW.DIYALARMFORUM.COM

Image 40
Contents Installation Guide Selecting a Suitable Location For The Alarm Controller Before Installing The EquipmentSafety Precautions required during Installation Table of Contents Page Installation & Wiring Technical SummaryInstallation Ensure connector key is oriented correctlyBurglary Zone Wiring Chart WiringMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Wireless Device Enrollment Enter Wireless Enrollment ModeActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Template Programming Zone Definitions Options 1Digit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out New Installations Refer to .1 Installation on Existing Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Alarm Memory Display Door Chime Enable/DisableTrouble Display Program User Codes7x Command Outputs 1&2 Installer ProgrammingAdditional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Programming Work Sheets Index to Programming Work Sheets and DescriptionsProgramming Worksheets Function Key ProgrammingFunction Key Options Zone DefinitionsInstaller’s Code Master Code System Times009 I/O Programming Keypad Lockout OptionsSecond System Options Third System OptionsFourth System Options Tenth System OptionsZone Loop Response Options Zone Attributes Options 10-13 are reserved for Future UsePGM Output Timer Cross Zone/Police Code TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Reporting Codes, Zones Alarm Restoral Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Restoral Reporting Codes, Zones Tamper Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Communicator Format Options Tamper/Restore Communicator Call DirectionsOpening/Closing Communicator Call Directions System Maintenance Communicator Call Directions System Test Transmissions Communicator Call DirectionsCommunication Variables Test Transmission Time of DayThird Communicator Options Second Communicator OptionsDownloading Options Number of Rings To Answer On Initiate PC-Link DownloadingPGM Output Attributes AttributeAutomatic Clock Adjust Delay Between Dialing Attempts600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless programming Wireless Zone Programming Wireless Supervisory WindowGeneral Wireless Options Wireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingLocal Keypad Programming Label Programming ZoneFire Alarm Label Alarm When Armed Event MessageCommand Output #1 Label Command Output #2 LabelReset Programmable Labels to Factory Defaults First Keypad OptionsSecond Keypad Options Third Keypad OptionsKeypad Function Key Programming Programming Descriptions002 Zone Definitions Installer Code System TimesMaster Code O Programming Zones/PGMsSecond System Options First System OptionsThird System Options Tenth System Options Fourth System OptionsOFF Keypad Always Active. The keypad does not blank Zone Loop Response Options 134 Zone AttributesDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackPGM Output Timer Cross Zone/Police Code TimerNo Activity Arm Timer Call Waiting Cancel StringTest Transmission Time Communicator VariablesFirst Communicator Options OFF Closing Confirmation Disabled. The keypad does not beep Second Communicator OptionsThird Communicator Options First Downloading OptionsDownloading Access Code Downloading Computer Phone NumberPanel Identification Code Number of Rings to Answer OnWay Audio Control Options applies to SCW9047 only Automatic Clock AdjustFollowing attributes are available for PGM Output Type Delay Between Dialing Attempts Wireless ProgrammingFirst International Options Second International OptionsWireless Module Placement Test Installer Lockout EnableInstaller Lockout Disable Restore Wireless Device Default ProgrammingFire Alarm Labels Alarm when Armed Event Message069 Command Output Label Keypad ProgrammingOFF Power LED is disabled. Option 6 has no effect First Keypad OptionsSecond Keypad Options Option Description Future UseLabel Reset Third Keypad OptionsProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 4 Failure to Communicate Trouble 8 Loss of Clock/DateAppendix a Reporting Code Formats Contact IDContact ID Zone Alarm/Restoral Event Codes SIA Format Automatic Zone Alarm/Restoral CodesAppendix B Communicator Format Options Pager Residential DialAppendix C Regulatory Approvals Information North AmericaEurope SIA False Alarm Reduction InstallationsNew Zealand Appendix D SIA False Alarm Reduction Exit TimeAppendix E 2-Way Audio Verification SCW9047 only Format Reporting Code/EventKey Command Description VOX SupportHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement