7.2 Programming Worksheets

[005] System Times

Valid entries for Entry Delay are between 030-255, valid entries for SIA CP-01 Exit Delay is between 045-255.

030

I___I___I___I

Entry Delay 1

045

I_0_I_3_I_0_I

Entry Delay 2

120

I_0_I_6_I_0_I

Exit Delay

004

I___I___I___I

Bell Cut-off

For SIA CP-01 compliant installations, the Exit Delay must be within the range of 045-255 seconds

(Default 60 seconds). If the Exit Delay is silent (Section 14, Option 6 or Stay Function Key Arming) the exit delay must be twice the programmed value but must not exceed 255 seconds (i.e., 090-255 seconds).

For UL Installations, the Entry Delay plus the Communications Delay must not exceed 60 seconds.

[006] Installer’s Code

[007] Master Code

 

 

 

Default

Default

 

 

 

 

5555

I I I I I

1234

I I I

I I

 

 

Programmable Output Options

 

 

 

 

 

00

Null PGM (Not Used)

 

 

10

System Event Output (with Event Options)

01

Residential Burglary and Fire Bell Output

 

 

11

System Tamper (all sources: zones, keypad)

02-04

Future Use

 

 

12

TLM and Alarm

 

05

System Armed Status

 

 

13-16

Future Use

 

06

Ready To Arm

 

 

17

Away Armed Status

 

07

Keypad Buzzer Follower

 

 

18

Stay Armed Status

 

08

Courtesy Pulse

 

 

19

Command Output #1 ([

][7][1])

09

System Trouble Output (with Trouble Options)

 

20

Command Output #2 ([

][7][2])

[009] I/O Programming

Program Zone Definition Attributes in Sections [133-134], Program PGM Option Attributes in sections [501] - [502]

Default

00

00

I I I

I I I

I/O Type (Zone 33, PGM 1)

Enter Zone Definition or PGM Definition

I/O Type (Zone 34, PGM 2)

Enter Zone Definition or PGM Definition

[012] Keypad Lockout Options

If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.

Default

000

000

I I I I

I I I I

Number of Invalid Codes Before Lockout

(Valid entries are 000-255)

Lockout Duration (in minutes)

(Valid entries are 000-255)

[013] First System Options

Opt

Def. ON

OFF

1

Hardwired Zone 33 Input Enabled

PGM1 Output Enabled

2

Hardwired Zone 34 Input Enabled

PGM2 Output Enabled

3-5

Future Use

 

6

Audible Exit Fault Enabled

Audible Exit Fault Disabled

7

Event Buffer follows Swinger Shutdown

Event Buffer Logs Past Shutdown

8

Temporal Three Fire Signal Enabled

Standard Pulsed Fire Signal

WWW.DIYALARMFORUM.COM17

Image 21
Contents Installation Guide Before Installing The Equipment Selecting a Suitable Location For The Alarm ControllerSafety Precautions required during Installation Table of Contents Page Technical Summary Installation & WiringEnsure connector key is oriented correctly InstallationWiring Burglary Zone Wiring ChartMax wire Length to End-of-line Resistor Self Contained Wireless Alarm System Enter Wireless Enrollment Mode Wireless Device EnrollmentActivate Wireless Device Verify Device Electronic Serial Number ESNZone Dependant Devices Detectors Zone Definitions Options 1 Template ProgrammingDigit 3 selects 1 of the 8 following options Installer Lead-in/Lead-out and DLS Lead-in/Lead-out Existing Installations Refer to .1 Installation on New Installations Refer to .1 Installation onDLS Programming Local Programming with PC-LinkOperation Door Chime Enable/Disable Alarm Memory DisplayTrouble Display Program User CodesInstaller Programming 7x Command Outputs 1&2Additional Keypad Functions 9User Code No-Entry ArmingAdvanced Programming Index to Programming Work Sheets and Descriptions Programming Work SheetsFunction Key Programming Programming WorksheetsFunction Key Options Zone DefinitionsSystem Times Installer’s Code Master Code009 I/O Programming Keypad Lockout OptionsThird System Options Second System OptionsFourth System Options Tenth System OptionsZone Attributes Options 10-13 are reserved for Future Use Zone Loop Response OptionsCross Zone/Police Code Timer PGM Output TimerNo Activity Arming Pre-alert Timer No Activity Arming TimerAlarm Restoral Reporting Codes, Zones Alarm Reporting Codes, ZonesMiscellaneous Alarm Reporting Codes Priority Alarm and Restoral Reporting CodesTamper Reporting Codes, Zones Tamper Restoral Reporting Codes, ZonesMiscellaneous Opening Disarming Reporting Codes Tamper/Restore Communicator Call Directions Communicator Format OptionsOpening/Closing Communicator Call Directions System Test Transmissions Communicator Call Directions System Maintenance Communicator Call DirectionsCommunication Variables Test Transmission Time of DaySecond Communicator Options Third Communicator OptionsDownloading Options Initiate PC-Link Downloading Number of Rings To Answer OnPGM Output Attributes AttributeDelay Between Dialing Attempts Automatic Clock Adjust600 2-way Audio Control Options Applies to SCW9047 only First International OptionsWireless Supervisory Window Wireless programming Wireless Zone ProgrammingWireless Module Placement Test Installer Lockout Enable General Wireless OptionsInstaller Lockout Disable Restore Wireless Device Default ProgrammingLabel Programming Zone Local Keypad ProgrammingAlarm When Armed Event Message Fire Alarm LabelCommand Output #1 Label Command Output #2 LabelFirst Keypad Options Reset Programmable Labels to Factory DefaultsSecond Keypad Options Third Keypad OptionsProgramming Descriptions Keypad Function Key Programming002 Zone Definitions System Times Installer CodeMaster Code O Programming Zones/PGMsFirst System Options Second System OptionsThird System Options Fourth System Options Tenth System OptionsOFF Keypad Always Active. The keypad does not blank 134 Zone Attributes Zone Loop Response OptionsDaylight Saving Time Move Clock Ahead Standard Time Set Clock BackCross Zone/Police Code Timer PGM Output TimerNo Activity Arm Timer Call Waiting Cancel StringCommunicator Variables Test Transmission TimeFirst Communicator Options Second Communicator Options OFF Closing Confirmation Disabled. The keypad does not beepThird Communicator Options First Downloading OptionsDownloading Computer Phone Number Downloading Access CodePanel Identification Code Number of Rings to Answer OnAutomatic Clock Adjust Way Audio Control Options applies to SCW9047 onlyFollowing attributes are available for PGM Output Type Wireless Programming Delay Between Dialing AttemptsFirst International Options Second International OptionsInstaller Lockout Enable Wireless Module Placement TestInstaller Lockout Disable Restore Wireless Device Default ProgrammingAlarm when Armed Event Message Fire Alarm Labels069 Command Output Label Keypad ProgrammingFirst Keypad Options OFF Power LED is disabled. Option 6 has no effectSecond Keypad Options Option Description Future UseThird Keypad Options Label ResetProgrammed LCD Message Programmed LCD Message DurationTesting & Troubleshooting Trouble 8 Loss of Clock/Date Trouble 4 Failure to CommunicateContact ID Appendix a Reporting Code FormatsSIA Format Automatic Zone Alarm/Restoral Codes Contact ID Zone Alarm/Restoral Event CodesAppendix B Communicator Format Options Residential Dial PagerNorth America Appendix C Regulatory Approvals InformationSIA False Alarm Reduction Installations EuropeNew Zealand Exit Time Appendix D SIA False Alarm ReductionFormat Reporting Code/Event Appendix E 2-Way Audio Verification SCW9047 onlyVOX Support Key Command DescriptionHang-up Auto-detection Bell/Buzzer Silent During 2-Way AudioPage FCC Compliance Statement